Cited by 24Bariatric Surgery and OutcomesMinimally Invasive Surgical TechniquesAirway Management and Intubation Techniques

Side-to-side magnetic duodeno-ileostomy in adults with severe obesity with or without type 2 diabetes: early outcomes with prior or concurrent sleeve gastrectomy

Open access
Gagner, Michel, Almutlaq, Lamees, Cadiere, Guy-Bernard, Torres, Antonio J., Sanchez-Pernaute, Andres, Buchwald, Jane N., Abuladze, David·2024·Surgery for Obesity and Related Diseases

Abstract

BACKGROUND: Conventional metabolic/bariatric surgical anastomoses with sutures/staples may cause severe adverse events (AEs). OBJECTIVES: The study aim was to evaluate the feasibility, safety, and effectiveness of primary and revisional side-to-side duodeno-ileostomy (DI) bipartition using a novel magnetic compression anastomosis device (Magnet Anastomosis System [MS]). SETTING: Multicenter: private practices and university hospitals. METHODS: ] ≥35.0 to ≤50.0 with/without type 2 diabetes [T2D] glycosylated hemoglobin [HbA1C > 6.5 %]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating magnet fusion and gradual DI (MagDI). The MagDI-after-SG group had undergone prior sleeve gastrectomy (SG); the MagDI + SG group underwent concurrent SG. AEs were graded by Clavien-Dindo Classification (CDC). RESULTS: Between November 22, 2021 and May 30, 2023, 43 patients (88.0% female, mean age 43.7 ± 1.3 years) underwent the study procedures. The MS met feasibility criteria of magnet device placement, creation of patent anastomoses confirmed radiologically, and magnet passage in 100.0% of patients. There were 64 AEs, most were CDC grade I and II, significantly fewer in the MagDI-after-SG group (P < .001). No device-related AEs including anastomotic leakage, bleeding, obstruction, infection, or death. The MagDI-after-SG group experienced 6-month mean weight loss of 8.0 ± 2.5 kg (P < .01), 17.4 ± 5.0% excess weight loss (EWL). The MagDI + SG group had significantly greater weight loss (34.2 ± 1.6 kg, P < .001), 66.2 ± 3.4% EWL. All patients with T2D improved. CONCLUSIONS: In early results of a multicenter study, the incisionless, sutureless Magnet System formed patent, complication-free anastomoses in side-to-side DI with prior or concurrent SG.

Integrity signals

Registry

Crossref · 10.1016/j.soard.2023.10.018

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gagner, M., Almutlaq, L., Cadiere, G.-B., Torres, A. J., Sanchez-Pernaute, A., Buchwald, J. N., & Abuladze, D.
Corresponding author
Gagner, Michel
Venue
Surgery for Obesity and Related Diseases
Publisher
Elsevier BV
Published
2024-04
Volume
20
Issue
4
Pages
341-352
ISSN
1550-7289 (ISSN-L)
OpenAlex
W4388561494
Cited by
24
References
1
Citations by year
2026: 11 · 2025: 9 · 2024: 4
FWCI
6.44
Type
journal article
Language
en
Open access
Locations
  • Surgery for Obesity and Related Diseases (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
  • Health Sciences › Medicine › Surgery › Minimally Invasive Surgical Techniques
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
magnetic compression anastomosis
MeSH terms
Adult, Diabetes Mellitus, Type 2, Duodenum, Female, Gastrectomy, Humans, Male, Middle Aged, Obesity, Obesity, Morbid, Retrospective Studies, Gastric Bypass, Weight Loss, Treatment Outcome, Magnetic Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review