Side-to-side magnetic duodeno-ileostomy in adults with severe obesity with or without type 2 diabetes: early outcomes with prior or concurrent sleeve gastrectomy
Open accessAbstract
BACKGROUND: Conventional metabolic/bariatric surgical anastomoses with sutures/staples may cause severe adverse events (AEs). OBJECTIVES: The study aim was to evaluate the feasibility, safety, and effectiveness of primary and revisional side-to-side duodeno-ileostomy (DI) bipartition using a novel magnetic compression anastomosis device (Magnet Anastomosis System [MS]). SETTING: Multicenter: private practices and university hospitals. METHODS: ] ≥35.0 to ≤50.0 with/without type 2 diabetes [T2D] glycosylated hemoglobin [HbA1C > 6.5 %]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating magnet fusion and gradual DI (MagDI). The MagDI-after-SG group had undergone prior sleeve gastrectomy (SG); the MagDI + SG group underwent concurrent SG. AEs were graded by Clavien-Dindo Classification (CDC). RESULTS: Between November 22, 2021 and May 30, 2023, 43 patients (88.0% female, mean age 43.7 ± 1.3 years) underwent the study procedures. The MS met feasibility criteria of magnet device placement, creation of patent anastomoses confirmed radiologically, and magnet passage in 100.0% of patients. There were 64 AEs, most were CDC grade I and II, significantly fewer in the MagDI-after-SG group (P < .001). No device-related AEs including anastomotic leakage, bleeding, obstruction, infection, or death. The MagDI-after-SG group experienced 6-month mean weight loss of 8.0 ± 2.5 kg (P < .01), 17.4 ± 5.0% excess weight loss (EWL). The MagDI + SG group had significantly greater weight loss (34.2 ± 1.6 kg, P < .001), 66.2 ± 3.4% EWL. All patients with T2D improved. CONCLUSIONS: In early results of a multicenter study, the incisionless, sutureless Magnet System formed patent, complication-free anastomoses in side-to-side DI with prior or concurrent SG.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
MAS combined with vertical sleeve gastrectomy results in 100% patent anastomosis with no leaks or serious adverse effects.
“The procedure resulted in a 100% patent anastomosis with no leaks or serious adverse effects.”
From Impact of Bariatric Surgery and Endoscopic Therapies on Liver Health in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Review (2025) · cites this paper as [108]
MAS with VSG groups show significant HbA1c reductions at six months.
“Both groups demonstrated significant HbA1c reductions at six months, with all patients reducing their need for antidiabetic medications [108].”
From Impact of Bariatric Surgery and Endoscopic Therapies on Liver Health in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Review (2025) · cites this paper as [108]
Simultaneous magnet placement with VSG yields 34.0% total weight loss at 12 months.
“At 12-month follow-up, patients who underwent simultaneous magnet placement with VSG achieved 34.0% TWL, while those who received MAS after VSG showed an 11.0% TWL.”
From Impact of Bariatric Surgery and Endoscopic Therapies on Liver Health in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Review (2025) · cites this paper as [108]
All patients reduce their need for antidiabetic medications after MAS with VSG.
“Both groups demonstrated significant HbA1c reductions at six months, with all patients reducing their need for antidiabetic medications [108].”
From Impact of Bariatric Surgery and Endoscopic Therapies on Liver Health in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Review (2025) · cites this paper as [108]
MAS after VSG yields 11.0% total weight loss at 12 months.
“At 12-month follow-up, patients who underwent simultaneous magnet placement with VSG achieved 34.0% TWL, while those who received MAS after VSG showed an 11.0% TWL.”
From Impact of Bariatric Surgery and Endoscopic Therapies on Liver Health in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Review (2025) · cites this paper as [108]
Cites
Role of weight bias and patient–physician communication in the underutilization of bariatric surgery
Sarwer, D. B., Gasoyan, H., Bauerle Bass, S., Spitzer, J. C., Soans, R., & Rubin, D. J. (2021) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2021.07.013 · Cited by 39 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Tasabehji, D., Saleh, S., & Mokadem, M. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14124012 · Cited by 14 · see citing works
- Authors
- Gagner, M., Almutlaq, L., Cadiere, G.-B., Torres, A. J., Sanchez-Pernaute, A., Buchwald, J. N., & Abuladze, D.
- Corresponding author
- Gagner, Michel
- Venue
- Surgery for Obesity and Related Diseases
- Publisher
- Elsevier BV
- Published
- 2024-04
- Volume
- 20
- Issue
- 4
- Pages
- 341-352
- ISSN
- 1550-7289 (ISSN-L)
- OpenAlex
- W4388561494
- Cited by
- 24
- References
- 1
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 4
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Surgery for Obesity and Related Diseases (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
- Health Sciences › Medicine › Surgery › Minimally Invasive Surgical Techniques
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Keywords
- magnetic compression anastomosis
- MeSH terms
- Adult, Diabetes Mellitus, Type 2, Duodenum, Female, Gastrectomy, Humans, Male, Middle Aged, Obesity, Obesity, Morbid, Retrospective Studies, Gastric Bypass, Weight Loss, Treatment Outcome, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review