Energy and exergy analysis of the PVT system: Effect of nanofluid flow rate
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Abstract Solar energy is one of the promising resources to fulfil the energy demands to some level in place of fossil fuels to avoid environmental pollution. The efficiency of solar technology, e.g. photovoltaic panels, thermal systems or a combination of both technologies as photovoltaic thermal is a concern to increase at an optimum level. A three-dimensional numerical analysis of PVT systems using water and MWCNT-water nanofluid has been completed with FEM based software COMSOL Multiphysics®. A numerical investigation has been validated by the indoor experimental research at different mass flow rates of 30 to 120 L/h while keeping solar irradiation fixed at 1000 W/m2, inlet fluid and ambient temperature at 32 and 25 °C, respectively. Percent improvement of electrical efficiency of PV with nanofluid cooling at flow rate 120 L/h is obtained about 10.72 and 12.25% of numerical and experimental cases respectively. Optimization of the nanofluid for weight concentration is achieved at 0.75% MWCNT-water. Solar cell temperature reduces about 0.72 °C experimentally and 0.77 °C numerically per 10 L/h flow rate increment. Approximately 7.74 and 6.89 W thermal energy is enhanced per 10 L/h flow rate increment in numerical and experimental studies respectively. Percentage increment of thermal efficiency is found as 5.62% numerically and 5.13% experimentally for PVT system operated by water/MWCNT nanofluid with compared to water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Viscosity of Concentrated Suspensions and Solutions
Brinkman, H. C. (1952) · The Journal of Chemical Physics · doi:10.1063/1.1700493 · Cited by 4,619
VII. Colours in metal glasses, in metallic films, and in metallic solutions.—II
Garnett, J. C. M. (1906) · Philosophical Transactions of the Royal Society of London. Series A, Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1906.0007 · Cited by 1,246
The Finite Element Method in Heat Transfer and Fluid Dynamics
Reddy, J. N., & Gartling, D. (2010) · CRC Press eBooks · doi:10.1201/9781439882573 · Cited by 1,135
Sardarabadi, M., Passandideh-Fard, M., & Zeinali Heris, S. (2014) · Energy · doi:10.1016/j.energy.2014.01.102 · Cited by 508
A state of the art review on viscosity of nanofluids
Murshed, S. M. S., & Estellé, P. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.113 · Cited by 456
Al-Waeli, A. H. A., Sopian, K., Chaichan, M. T., Kazem, H. A., Ibrahim, A., Mat, S., & Ruslan, M. H. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.09.032 · Cited by 433
Sardarabadi, M., & Passandideh-Fard, M. (2016) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2016.07.008 · Cited by 334
Cooling methodologies of photovoltaic module for enhancing electrical efficiency: A review
Shukla, A., Kant, K., Sharma, A., & Biwolé, P. H. (2016) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2016.10.047 · Cited by 334
Application of Computational Fluid Dynamics (CFD) for nanofluids
Kamyar, A., Saidur, R., & Hasanuzzaman, M. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.03.052 · Cited by 317
Self-citationAl-Shamani, A. N., Sopian, K., Mat, S., Hasan, H. A., Abed, A. M., & Ruslan, M. H. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.07.052 · Cited by 289
Experimental investigation of a PVT system performance using nano ferrofluids
Ghadiri, M., Sardarabadi, M., Pasandideh-fard, M., & Moghadam, A. J. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.06.077 · Cited by 287
Xu, Z., & Kleinstreuer, C. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.07.047 · Cited by 235
Exergy analysis on solar thermal systems: A better understanding of their sustainability
Kalogirou, S. A., Karellas, S., Bădescu, V., & Braimakis, K. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.05.037 · Cited by 225
Photovoltaic/thermal (PVT) systems: A review with emphasis on environmental issues
Lamnatou, C., & Chemisana, D. (2017) · Renewable Energy · doi:10.1016/j.renene.2016.12.009 · Cited by 207
A cascade nanofluid-based PV/T system with optimized optical and thermal properties
Hassani, S., Taylor, R. A., Mekhilef, S., & Saidur, R. (2016) · Energy · doi:10.1016/j.energy.2016.06.142 · Cited by 187
Lari, M. O., & Şahin, A. Z. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.07.045 · Cited by 157
Zamzamian, S. A. H., Keyanpour-Rad, M., KianiNeyestani, M., & Jamal‐Abad, M. T. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.06.003 · Cited by 154
An, W., Zhang, J., Zhu, T., & Gao, N. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.08.080 · Cited by 122
Hust, J. G., & Lankford, A. B. (1984) · doi:10.6028/nbs.ir.84-3007 · Cited by 117
Metadata
- Authors
- Fayaz, H., Nasrin, R., Rahim, N. A., & Hasanuzzaman, M.
- Venue
- Solar Energy
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 169
- Pages
- 217-230
- ISSN
- 0038-092X (ISSN-L)
- OpenAlex
- W2799694892
- Cited by
- 195
- References
- 19
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.