Cited by 95Analytical chemistry methods developmentElectrochemical Analysis and ApplicationsRadioactive element chemistry and processing

Deep eutectic solvent based advance microextraction method for determination of aluminum in water and food samples: Multivariate study

Panhwar, Abdul Haleem, Tuzen, Mustafa, Kazi, Tasneem Gul·2018·Talanta

Abstract

Preconcentration of aluminum Al 3+ was carried out by a novel deep eutectic solvent based ultrasound-assisted liquid phase microextraction (DES-UALPME) method. The deep eutectic solvents (DESs), a green solvent was first time used for enrichment and quantification of very low concentration of Al 3+ in water and food samples, prior to analysed by electrothermal atomic absorption spectrometry (ETAAS). In present method it was observed that % recovery of Al-8-hydroxyquinoline chelates efficiently extracted by DES solvent. Pre-enrichment factor and limit of detection were observed to be 50, and 0.032μgL -1 , respectively. Developed procedure was validated with the CRM (SLRS-5 river water) of Al and a good agreement was observed in results of measured value to the certified value. The RSD was calculated as 3.3%. The presented procedure was successfully carried out to different water and food samples.

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2017.09.079

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hydrophilic DESs have been used in microextraction techniques for detection of aluminum and dyes.

    “Apart from the direct use of hydrophilic DESs in the development of sophisticated microextraction techniques for the detection of very low concentration of diverse micropollutants, such as aluminum (Al 3 þ ) [7] and dyes [8]”

    From Deep eutectic solvents: overcoming 21st century challenges (2019) · cites this paper as [7]

  • Hydrophilic DESs have been used in smart materials such as magnetic gels and carbon nanotube/graphene nanoparticles for removal of nitroaromatic explosives, aluminum, lead, arsenic, and mercury from water.

    “these compounds have also been advantageously used in the preparation of smart materials such as magnetic gels [9] and nanoparticles based on carbon nanotubes and graphene for the removal nitroaromatic explosives [9], aluminum [7], lead [10], arsenic [11], and mercury [12] from water.”

    From Deep eutectic solvents: overcoming 21st century challenges (2019) · cites this paper as [7]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 36 · Cited by 95

Authors
Panhwar, A. H., Tuzen, M., & Kazi, T. G.
Affiliations
University of Sindh (PK)
Venue
Talanta
Publisher
Elsevier BV
Published
2018-02
Volume
178
Pages
588-593
ISSN
0039-9140 (ISSN-L)
OpenAlex
W2760534760
Cited by
95
References
36
Citations by year
2026: 2 · 2025: 9 · 2024: 9 · 2023: 9 · 2022: 14 · 2021: 11 · 2020: 10 · 2019: 20 · 2018: 11
FWCI
7.84
Type
journal article
Language
en
Open access
closed
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
Funders
Scientific and Technological Research Council of Turkey
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
Keywords
deep eutectic solvents, aluminum determination, preconcentration, graphite furnace atomic absorption spectrometry, water samples, food samples, green solvents, multivariate analysis
MeSH terms
Agaricales, Aluminum, Animals, Chickens, Choline, Food Contamination, Meat, Mineral Waters, Oryza, Seawater, Solvents, Water Pollutants, Chemical, Phenol, Rivers, Liquid Phase Microextraction, Drinking Water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review