Deep eutectic solvent based advance microextraction method for determination of aluminum in water and food samples: Multivariate study
Abstract
Preconcentration of aluminum Al 3+ was carried out by a novel deep eutectic solvent based ultrasound-assisted liquid phase microextraction (DES-UALPME) method. The deep eutectic solvents (DESs), a green solvent was first time used for enrichment and quantification of very low concentration of Al 3+ in water and food samples, prior to analysed by electrothermal atomic absorption spectrometry (ETAAS). In present method it was observed that % recovery of Al-8-hydroxyquinoline chelates efficiently extracted by DES solvent. Pre-enrichment factor and limit of detection were observed to be 50, and 0.032μgL -1 , respectively. Developed procedure was validated with the CRM (SLRS-5 river water) of Al and a good agreement was observed in results of measured value to the certified value. The RSD was calculated as 3.3%. The presented procedure was successfully carried out to different water and food samples.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hydrophilic DESs have been used in microextraction techniques for detection of aluminum and dyes.
“Apart from the direct use of hydrophilic DESs in the development of sophisticated microextraction techniques for the detection of very low concentration of diverse micropollutants, such as aluminum (Al 3 þ ) [7] and dyes [8]”
From Deep eutectic solvents: overcoming 21st century challenges (2019) · cites this paper as [7]
Hydrophilic DESs have been used in smart materials such as magnetic gels and carbon nanotube/graphene nanoparticles for removal of nitroaromatic explosives, aluminum, lead, arsenic, and mercury from water.
“these compounds have also been advantageously used in the preparation of smart materials such as magnetic gels [9] and nanoparticles based on carbon nanotubes and graphene for the removal nitroaromatic explosives [9], aluminum [7], lead [10], arsenic [11], and mercury [12] from water.”
From Deep eutectic solvents: overcoming 21st century challenges (2019) · cites this paper as [7]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 36 · Cited by 95
- Authors
- Panhwar, A. H., Tuzen, M., & Kazi, T. G.
- Affiliations
- University of Sindh (PK)
- ORCID
- Kazi, Tasneem Gul
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 178
- Pages
- 588-593
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2760534760
- Cited by
- 95
- References
- 36
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 9 · 2023: 9 · 2022: 14 · 2021: 11 · 2020: 10 · 2019: 20 · 2018: 11
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Scientific and Technological Research Council of Turkey
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
- Keywords
- deep eutectic solvents, aluminum determination, preconcentration, graphite furnace atomic absorption spectrometry, water samples, food samples, green solvents, multivariate analysis
- MeSH terms
- Agaricales, Aluminum, Animals, Chickens, Choline, Food Contamination, Meat, Mineral Waters, Oryza, Seawater, Solvents, Water Pollutants, Chemical, Phenol, Rivers, Liquid Phase Microextraction, Drinking Water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review