The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Ammonia gas sensors: A comprehensive review
Open accessAbstract
In recent years, sensitive, selective and accurate sensing techniques for ammonia gas detection have been highly demanded since ammonia is both a commonly utilized gas in various industrial sectors and a highly toxic and corrosive agent that can threat human health and environment. This review article discusses the widely used gas sensing techniques in ammonia detection. The fundamental working principles of the ammonia detection techniques relying on electronics, electrochemistry, tunable diode laser spectroscopy, surface acoustic wave, and field effect transistors are briefly described first, in conjunction with various sensing materials. Furthermore, recent progress in the development of advanced ammonia gas sensors was comprehensively reviewed and summarized. Finally, the outlook for future development of high-performance ammonia sensors was presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal Oxide Gas Sensors: Sensitivity and Influencing Factors
Wang, C., Yin, L., Zhang, L., Xiang, D., & Gao, R. (2010) · Sensors · doi:10.3390/s100302088 · Cited by 2,928
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Ammonia sensors and their applications—a review
Timmer, B., Olthuis, W., & Berg, A. V. D. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.11.054 · Cited by 1,714
Metal oxide-based gas sensor research: How to?
BARSAN, N., KOZIEJ, D., & WEIMAR, U. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.047 · Cited by 1,696
Metal oxides for solid-state gas sensors: What determines our choice?
Korotcenkov, G. (2007) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2007.01.044 · Cited by 1,670
Gas Sensors Based on Conducting Polymers
Bai, H., & Shi, G. (2007) · Sensors · doi:10.3390/s7030267 · Cited by 1,577
A Survey on Gas Sensing Technology
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., & Ning, H. (2012) · Sensors · doi:10.3390/s120709635 · Cited by 1,416
Cited by
Gas sensing mechanisms of metal oxide semiconductors: a focus review
Ji, H., Zeng, W., & Li, Y. (2019) · Nanoscale · doi:10.1039/c9nr07699a · Cited by 1,108
Metal-oxide semiconductors for carbon monoxide (CO) gas sensing: A review
Mahajan, S., & Jagtap, S. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2019.100483 · Cited by 400
Metal oxide semiconductors for gas sensing
Goel, N., Kunal, K., Kushwaha, A., & Kumar, M. (2023) · Engineering Reports · doi:10.1002/eng2.12604 · Cited by 294
Zhu, H., Ji, H., Yuan, Z., Shen, Y., Gao, H., & Meng, F. (2023) · Journal of Materials Chemistry A · doi:10.1039/d3ta01426f · Cited by 59
Metadata
- Authors
- Kwak, D., Lei, Y., & Maric, R.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 204
- Pages
- 713-730
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2949604470
- Cited by
- 690
- References
- 94
- FWCI
- 20.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.