Molecularly imprinted polymer-based sensor for electrochemical detection of erythromycin
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The increasing global reports on the occurrence of macrolide antibiotics resistance, especially erythromycin (Ery) resistant strains, suggests the possible presence of these antibiotics in the environment hence, their inclusion in the EU watchlist of water pollutants. Consequently, there is an urgent need for the development of portable and cost effective analytical sensing devices for their monitoring in water. The combination of molecularly imprinted polymer (MIP) as a sensing element with a portable electrochemical transducer such as screen printed electrode (SPE) may offer a valuable approach for the desired routine environmental monitoring. This work demonstrates the preparation of an electrochemical MIP-based sensor for Ery detection in aqueous media. Ery-selective MIP, Ery-MIP was generated directly on SPE, Ery-MIP/SPE via electrochemical polymerization of m-phenylenediamine (mPD). The optimization of sensor performance was achieved with special attention given to the selection of functional monomer, template removal, polymer thickness and incubation time. Ery-MIP/SPE sensor demonstrated the ability to discriminate target analyte against very close analogues i.e clarithromycin and azithromycin in both PBS and tap water. In addition, Ery-MIP/SPE could detect Ery down to low limits (LOD = 0.1 nM and LOQ = 0.4 nM) and exhibited good recovery in tap water. The presented analytical approach could be potentially suited and/or further developed for adequate monitoring of Ery as well as other macrolides in environmental water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Antibiotic resistance genes in water environment
Zhang, X.-X., Zhang, T., & Fang, H. H. P. (2009) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-008-1829-z · Cited by 998
Electrochemical sensors: a powerful tool in analytical chemistry
Stradiotto, N. R., Yamanaka, H., & Zanoni, M. V. B. (2003) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50532003000200003 · Cited by 514
Pichon, V., & Chapuis-Hugon, F. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.057 · Cited by 451
Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring
Hayat, A., & Marty, J. (2014) · Sensors · doi:10.3390/s140610432 · Cited by 432
Electrochemical Sensors Based on Molecularly Imprinted Polymers
Piletsky, S. A., & Turner, A. P. F. (2002) · Electroanalysis · doi:10.1002/1521-4109(200203)14:5<317::aid-elan317>3.0.co;2-5 · Cited by 282
Kröger, S., Turner, A. P. F., Mosbach, K., & Haupt, K. (1999) · Analytical Chemistry · doi:10.1021/ac9811827 · Cited by 267
Electrochemical Sensors Based on Molecularly Imprinted Polymers
Piletsky, S. A., & Turner, A. P. F. (2002) · Electroanalysis · Cited by 245
Lorenzo, R. A., Carro, A. M., Alvarez-Lorenzo, C., & Concheiro, A. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074327 · Cited by 243
Hernandez-Vargas, G., Sosa-Hernández, J., Saldarriaga-Hernandez, S., Villalba-Rodríguez, A., Parra-Saldivar, R., & Iqbal, H. (2018) · Biosensors · doi:10.3390/bios8020029 · Cited by 240
Erythromycin-Resistant Group A Streptococci in Schoolchildren in Pittsburgh
Martin, J. M., Green, M., Barbadora, K. A., & Wald, E. R. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013169 · Cited by 234
Recent Advances in Electrochemical Sensors Based on Molecularly Imprinted Polymers and Nanomaterials
Lahcen, A. A., & Amine, A. (2019) · Electroanalysis · doi:10.1002/elan.201800623 · Cited by 212
From Erythromycin to Azithromycin and New Potential Ribosome-Binding Antimicrobials
Jelić, D., & Antolović, R. (2016) · Antibiotics · doi:10.3390/antibiotics5030029 · Cited by 202
Genetic Elements Responsible for Erythromycin Resistance in Streptococci
Varaldo, P. E., Montanari, M. P., & Giovanetti, E. (2008) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00781-08 · Cited by 184
Protein-Imprinted Polymers: The Shape of Things to Come?
Culver, H. R., & Peppas, N. A. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b01936 · Cited by 165
Erythromycin Resistance Genes in Group A Streptococci in Finland
Kataja, J., Huovinen, P., Skurnik, M., the Finnish Study Group for Antimicrobial Resistance, & Seppälä, H. (1999) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.43.1.48 · Cited by 158
Michael-Kordatou, I., Iacovou, M., Frontistis, Z., Hapeshi, E., Dionysiou, D. D., & Fatta‐Kassinos, D. (2015) · Water Research · doi:10.1016/j.watres.2015.08.050 · Cited by 152
Desjardins, M., Delgaty, K. L., Ramotar, K., Seetaram, C., & Toye, B. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.12.5620-5623.2004 · Cited by 130
Silva, B. V. M., Rodríguez, B. A. G., Sales, M. G. F., Sotomayor, M. D. P. T., & Dutra, R. F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.068 · Cited by 124
Marć, M., Kupka, T., Wieczorek, P. P., & Namieśnik, J. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.020 · Cited by 112
Couto, R. A. S., da Costa, S. S., Mounssef, B., Pacheco, J. G., Fernandes, E. G. R., Carvalho, F. D., Rodrigues, C. M. P., Delerue-Matos, C. M., Braga, A. A. C., Gonçalves, L. M., et al. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.03.138 · Cited by 109
Ratautaitė, V., Plaušinaitis, D., Plikusienė, I., Mikoliūnaitė, L., Ramanavičienė, A., & Ramanavičius, A. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.01.109 · Cited by 101
Grafting of molecularly imprinted polymers on iniferter-modified carbon nanotube
Lee, H.-Y., & Kim, B. S. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.040 · Cited by 80
Molecularly imprinted poly(meta-phenylenediamine) based QCM sensor for detecting Amoxicillin
Ayankojo, A. G., Reut, J., Boroznjak, R., Öpik, A., & Syritski, V. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.194 · Cited by 80
Self-citationXie, Y., Hu, Q., Zhao, M., Cheng, Y., Guo, Y., He, Q., & Yao, W. (2017) · Food Analytical Methods · doi:10.1007/s12161-017-1008-x · Cited by 54
Clonality of erythromycin resistance inFrancisella tularensis
Karlsson, E., Golovliov, I. R., Lärkeryd, A., Granberg, M., Larsson, E., Öhrman, C., Niemcewicz, M., Birdsell, D. N., Wagner, D. M., Forsman, M., et al. (2016) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkw235 · Cited by 49
Molecular subtyping and erythromycin resistance ofCampylobacterin China
Zhang, A., Song, L., Liang, H., Gu, Y., Zhang, C., Liu, X., Zhang, J., & Zhang, M. (2016) · Journal of Applied Microbiology · doi:10.1111/jam.13135 · Cited by 42
Zhu, Y., Jiang, D.-Y., Sun, D., Yan, Y., & Li, C. (2016) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2016.07.036 · Cited by 31
Cited by
Molecularly imprinted polymer-based electrochemical sensors for environmental analysis
Rebelo, P., Costa-Rama, E., Seguro, I., Pacheco, J. G., Nouws, H. P. A., Cordeiro, M. N. D. S., & Delerue-Matos, C. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112719 · Cited by 325
Metadata
- Authors
- Ayankojo, A. G., Reut, J., Ciocan, V., Öpik, A., & Syritski, V.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 209
- Pages
- 120502
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2981858357
- Cited by
- 178
- References
- 28
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.