Intra- and inter-laboratory reproducibility and accuracy of the LuSens assay: A reporter gene-cell line to detect keratinocyte activation by skin sensitizers
Open accessThe DOI matches its Crossref record.
Abstract
Several non-animal methods are now available to address the key events leading to skin sensitization as defined by the adverse outcome pathway. The KeratinoSens assay addresses the cellular event of keratinocyte activation and is a method accepted under OECD TG 442D. In this study, the results of an inter-laboratory evaluation of the "me-too" LuSens assay, a bioassay that uses a human keratinocyte cell line harboring a reporter gene construct composed of the rat antioxidant response element (ARE) of the NADPH:quinone oxidoreductase 1 gene and the luciferase gene, are described. Earlier in-house validation with 74 substances showed an accuracy of 82% in comparison to human data. When used in a battery of non-animal methods, even higher predictivity is achieved. To meet European validation criteria, a multicenter study was conducted in 5 laboratories. The study was divided into two phases, to assess 1) transferability of the method, and 2) reproducibility and accuracy. Phase I was performed by testing 8 non-coded test substances; the results showed a good transferability to naïve laboratories even without on-site training. Phase II was performed with 20 coded test substances (performance standards recommended by OECD, 2015). In this phase, the intra- and inter-laboratory reproducibility as well as accuracy of the method was evaluated. The data demonstrate a remarkable reproducibility of 100% and an accuracy of over 80% in identifying skin sensitizers, indicating a good concordance with in vivo data. These results demonstrate good transferability, reliability and accuracy of the method thereby achieving the standards necessary for use in a regulatory setting to detect skin sensitizers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-animal methods to predict skin sensitization (I): the Cosmetics Europe database
Hoffmann, S., Kleinstreuer, N., Alépée, N., Allen, D., Api, A. M., Ashikaga, T., Clouet, E., Cluzel, M., Desprez, B., Gellatly, N., et al. (2018) · Critical Reviews in Toxicology · doi:10.1080/10408444.2018.1429385 · Cited by 188
“…to the KeratinoSensTM and the Peroxidase Peptide Reactivity Assay (PPRA) is a refined version of the DRPA, i.e. by using liquid chromatography and tandem mass spectrometry, and by introducing oxidative capacity via the addition of horseradish peroxidase (Gerberick et al. 2009; Ramirez et al. 2016).”
BackgroundSelf-citationLeontaridou, M. (2017) · ALTEX · doi:10.14573/altex.1606271 · Cited by 46
“LuSens (Ramirez et al., 2014; Ramirez et al., 2016) also covers the ARE-Nrf2 luciferase testing method and is currently undergoing validation.”
MethodKolle, S. N., Mathea, M., Natsch, A., & Landsiedel, R. (2021) · Applied In Vitro Toxicology · doi:10.1089/aivt.2021.0003 · Cited by 16
“17 During the validation of new methods, reproducibility within one laboratory and between laboratories is assessed in multila-boratory ring trials and a set of typically 20–30 substances is assessed in multiple runs in multiple laboratories.”
Self-citation
Metadata
- Authors
- Ramirez, T., Stein, N., Aumann, A., Remus, T., Edwards, A., Norman, K. G., Ryan, C., Bader, J. E., Fehr, M., Burleson, F., Foertsch, L., Wang, X., Gerberick, F., Beilstein, P., Hoffmann, S., Mehling, A., van Ravenzwaay, B., & Landsiedel, R.
- Venue
- Toxicology in Vitro
- Publisher
- Elsevier BV
- Published
- 2016-04
- Volume
- 32
- Pages
- 278-286
- ISSN
- 0887-2333 (ISSN-L)
- OpenAlex
- W2236384721
- Cited by
- 49
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.