The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Current trends in the development of conducting polymers-based biosensors
Abstract
Abstract Bioelectronics devices are seeing great improvement. After the earliest generations of sensors and biosensors, the current generation is attracting great interest due to the advantages that it showed. Despite the positive advantages, some drawbacks linked to the technologies used in the construction process are still seen. Therefore, the scientific community is giving its best to further develop the current biosensor knowledge and bypass the disadvantages seen before. In this review, we will be examining the current approaches taken by research in order to avoid the already seen drawbacks in sensors development. Many tools and methodologies are being used ranging from conducting polymers, conducting polymer nanowires, embedded metal nanoparticles in polymeric films, to conducting polymers synthesis in ionic liquids and polymeric ionic liquids. These approaches permitted the fabrication of highly simplistic and low-cost biosensors stressing on their potential in biological samples detection. The dynamic seen between polymers and protein opens the door to many possibilities to use novel materials or devising new techniques for the next generation biosensor systems. Despite all the efforts been made, the subject of modification of electrodes by chemical reactions is still a remarkable area of research activity. Hence, in this review, the considerable emphasis has been placed on the recent approaches of electrical active polymer modified electrodes specialized for application in biosensing devices and in particular amperometric biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Cited by
Progress in Conductive Polyaniline-Based Nanocomposites for Biomedical Applications: A Review
Zare, E. N., Makvandi, P., Ashtari, B., Rossi, F., Motahari, A., & Perale, G. (2020) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.9b00803 · Cited by 481
Ramesh, M., Janani, R., Deepa, C., & Rajeshkumar, L. (2022) · Biosensors · doi:10.3390/bios13010040 · Cited by 443
Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis
Purohit, B., Vernekar, P. R., Shetti, N. P., & Chandra, P. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100040 · Cited by 421
Conducting Polymers in the Design of Biosensors and Biofuel Cells
Ramanavicius, S., & Ramanavicius, A. (2020) · Polymers · doi:10.3390/polym13010049 · Cited by 307
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Metadata
- Authors
- Ghorbani Zamani, F., Moulahoum, H., Ak, M., Odaci Demirkol, D., & Timur, S.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 118
- Pages
- 264-276
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2949374330
- Cited by
- 161
- References
- 1
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current trends in the development of conducting polymers-based biosensors. https://app.cochat.ai/papers/10.1016/j.trac.2019.05.031
- The paper
- Ghorbani Zamani, F., Moulahoum, H., Ak, M., Odaci Demirkol, D., & Timur, S. (2019). Current trends in the development of conducting polymers-based biosensors. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/j.trac.2019.05.031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.