CoChat

Adverse events in apheresis: An update of the WAA registry data

Open access
Mörtzell Henriksson, M., Newman, E., Witt, V., Derfler, K., Leitner, G., Eloot, S., Dhondt, A., Deeren, D., Rock, G., Ptak, J., Blaha, M., Lanska, M., Gasova, Z., Hrdlickova, R., Ramlow, W., Prophet, H., Liumbruno, G., Mori, E., Griskevicius, A., Audzijoniene, J., Vrielink, H., Rombout, S., Aandahl, A., Sikole, A., Tomaz, J., Lalic, K., Mazic, S., Strineholm, V., Brink, B., Berlin, G., Dykes, J., Toss, F., Axelsson, C.G., Stegmayr, B., Nilsson, T., Norda, R., Knutson, F., Ramsauer, B., Wahlström, A. · 2016 · Transfusion and Apheresis Science
Cited by 152

The DOI matches its Crossref record.

Abstract

Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.transci.2016.01.003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 152

Metadata

Authors
Mörtzell Henriksson, M., Newman, E., Witt, V., Derfler, K., Leitner, G., Eloot, S., Dhondt, A., Deeren, D., Rock, G., Ptak, J., Blaha, M., Lanska, M., Gasova, Z., Hrdlickova, R., Ramlow, W., Prophet, H., Liumbruno, G., Mori, E., Griskevicius, A., Audzijoniene, J., Vrielink, H., Rombout, S., Aandahl, A., Sikole, A., Tomaz, J., Lalic, K., Mazic, S., Strineholm, V., Brink, B., Berlin, G., Dykes, J., Toss, F., Axelsson, C. G., Stegmayr, B., Nilsson, T., Norda, R., Knutson, F., Ramsauer, B., & Wahlström, A.
Venue
Transfusion and Apheresis Science
Publisher
Elsevier BV
Published
2016-02
Volume
54
Issue
1
Pages
2-15
ISSN
1473-0502 (ISSN-L)
OpenAlex
W2236155577
Cited by
152
References
0
FWCI
6.27
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adverse events in apheresis: An update of the WAA registry data. https://app.cochat.ai/papers/10.1016/j.transci.2016.01.003
The paper
Mörtzell Henriksson, M., Newman, E., Witt, V., Derfler, K., Leitner, G., Eloot, S., Dhondt, A., Deeren, D., Rock, G., Ptak, J., Blaha, M., Lanska, M., Gasova, Z., Hrdlickova, R., Ramlow, W., Prophet, H., Liumbruno, G., Mori, E., Griskevicius, A., . . . Wahlström, A. (2016). Adverse events in apheresis: An update of the WAA registry data. Transfusion and Apheresis Science. https://doi.org/10.1016/j.transci.2016.01.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.