Microscopic images transmitted by mobile cameraphone
The DOI matches its Crossref record.
Abstract
Remote expert viewing of medical images (telemedicine) is well established. An emerging variant is transmission of images captured by mobile (cellular) telephone cameras. This technique has been used to aid diagnosis and management of problems in, among others, urology, emergency sonography and neurosurgery (Blaivas et al., 2005; Piek et al., 2006; Rasdan et al., 2006). A novel application of mobile cameraphone technology is the capture and transmission of images directly from the eyepiece of an ordinary laboratory microscope. The only equipment required is a spacer that allows the mobile phone camera to be held steady at the correct distance from, and parallel to, the microscope eyepiece lens. I used a plastic bottle cap, 35 mm in diameter and 13 mm deep, with an aperture about the diameter of the eyepiece lens (20 mm) cut out of it. When the microscopic field to be captured is in focus, the spacer, cupped against the microscope eyepiece, is sandwiched between the camera and the eyepiece. By viewing the phone display and carefully adjusting the camera position, the image is centred, refocused if necessary, and captured. It can then be transmitted directly to another mobile phone or, ideally, to a computer, where it can be enlarged and enhanced, for expert opinion and permanent record. The resolution and colour reproduction of the image is limited by the camera's quality. I used a basic mobile phone camera with a resolution of 640 × 480 pixels. This is sufficient to transmit images of objects of moderate size, such as a malaria gametocyte, or trypanosomes on a Giemsa-stained blood film (Figure 1 ), but not very small or subtle microscopic detail. However, mobile cameraphones are becoming ever cheaper and more sophisticated, with high resolution, zoom lenses, autofocus and video capture commonplace. The ubiquity of mobile phone networks will allow application of this simple technique in many situations where the dedicated and expensive microscope, camera, software, and computer network required for conventional telemedicine do not exist; for example, in rural diagnostic laboratories in developing countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
The use of mobile phones as a data collection tool: A report from a household survey in South Africa
Tomlinson, M., Solomon, W., Singh, Y., Doherty, T., Chopra, M., Ijumba, P., Tsai, A. C., & Jackson, D. (2009) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-9-51 · Cited by 340
“Additionally, other studies have investigated the use of cell phones on the provider end to transmit images for documentation [14] or diagnostic purposes [15-18].”
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, A., Reber, C. D., Switz, N. A., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096906 · Cited by 196
Tuijn, C. J., Hoefman, B. J., van Beijma, H., Oskam, L., & Chevrollier, N. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028348 · Cited by 60
Metadata
- Authors
- Frean, J.
- Venue
- Transactions of the Royal Society of Tropical Medicine and Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-10
- Volume
- 101
- Issue
- 10
- Pages
- 1053
- ISSN
- 0035-9203 (ISSN-L)
- OpenAlex
- W2031104662
- Cited by
- 31
- References
- 0
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microscopic images transmitted by mobile cameraphone. https://app.cochat.ai/papers/10.1016/j.trstmh.2007.06.008
- The paper
- Frean, J. (2007). Microscopic images transmitted by mobile cameraphone. Transactions of the Royal Society of Tropical Medicine and Hygiene. https://doi.org/10.1016/j.trstmh.2007.06.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.