Nonspherical Oscillations of Ultrasound Contrast Agent Microbubbles
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leighton, T. G. (2012) · Cited by 2,284
Single-bubble sonoluminescence
Brenner, M. P., Hilgenfeldt, S., & Lohse, D. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.425 · Cited by 1,052
Self-citationCavitation Bubbles Near Boundaries
Blake, J. R., & Gibson, D. C. (1987) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.19.010187.000531 · Cited by 848 · cited 1×
“This asymmetry is well known in the context of cavitation, where the collapse of bubbles in the vicinity of a wall can lead to the formation of a jet toward the wall (Blake and Gibson 1987; Klaseboer et al. 2005; Ohl et al. 2006).”
A model for large amplitude oscillations of coated bubbles accounting for buckling and rupture
Marmottant, P., van der Meer, S., Emmer, M., Versluis, M., de Jong, N., Hilgenfeldt, S., & Lohse, D. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.2109427 · Cited by 774 · cited 1×
“To understand the origin of the sound scattered by UCA microbubbles, all existing models have focused on describing the spherical oscillations of coated bubbles (de Jong et al. 1994; Church 1995; Hoff et al. 2000; Khismatullin and Nadim 2002; Sarkar et al. 2005; Marmottant et al. 2005).”
Self-citationNonlinear Oscillations in Physical Systems
Ritchie, C. C. (1965) · Physics Bulletin · doi:10.1088/0031-9112/16/7/016 · Cited by 768
Nonlinear oscillations in physical systems
林, 千. (1964) · Medical Entomology and Zoology · Cited by 724
Numerical investigation of nonlinear oscillations of gas bubbles in liquids
Lauterborn, W. (1976) · The Journal of the Acoustical Society of America · doi:10.1121/1.380884 · Cited by 534 · cited 1×
“7b (hence for pressures higher than 150 kPa) is lower by about 20%; this difference is because increasing the applied pressure amplitude decreases the resonance frequency, as is already known for uncoated bubbles (Lauterborn 1976).”
Sonoporation from Jetting Cavitation Bubbles
Ohl, C.-D., Arora, M., Ikink, R., de Jong, N., Versluis, M., Delius, M., & Lohse, D. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.075366 · Cited by 498 · cited 1×
“This asymmetry is well known in the context of cavitation, where the collapse of bubbles in the vicinity of a wall can lead to the formation of a jet toward the wall (Blake and Gibson 1987; Klaseboer et al. 2005; Ohl et al. 2006).”
BackgroundSelf-citationUltrasound contrast imaging: current and new potential methods
Frinking, P. J. A., Bouakaz, A., Kirkhorn, J., Ten Cate, F. J., & de Jong, N. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00229-5 · Cited by 378
Self-citationSubharmonic imaging of contrast agents
Forsberg, F., Shi, W. T., & Goldberg, B. B. (2000) · Ultrasonics · doi:10.1016/s0041-624x(99)00148-1 · Cited by 303 · cited 1×
“E-mail: benjamin.dollet@univ-rennes1.fr 1465 1998; Krishna et al. 1999; Forsberg et al. 2000).”
Sarkar, K., Shi, W. T., Chatterjee, D., & Forsberg, F. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1923367 · Cited by 295 · cited 1×
“To understand the origin of the sound scattered by UCA microbubbles, all existing models have focused on describing the spherical oscillations of coated bubbles (de Jong et al. 1994; Church 1995; Hoff et al. 2000; Khismatullin and Nadim 2002; Sarkar et al. 2005; Marmottant et al. 2005).”
Bubble Shape Oscillations and the Onset of Sonoluminescence
Brenner, M. P., Lohse, D., & Dupont, T. F. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.954 · Cited by 203 · cited 3×
“…studies describe the surface mode dynamics of uncoated bubbles (Plesset 1954; Eller and Crum 1970; Prosperetti 1977; Francescutto and Nabergoj 1978; Brenner et al. 1995; Hilgenfeldt et al. 1996; Grossmann et al. 1997; Brenner et al. 2002) as a linear ordinary differential equation (ODE) for an.”
Self-citationOptical observation of contrast agent destruction
Chomas, J. E., Dayton, P. A., May, D. J., Allen, J. S., Klibanov, A. L., & Ferrara, K. W. (2000) · Applied Physics Letters · doi:10.1063/1.1287519 · Cited by 157 · cited 1×
“The studied range of acoustic pressure ( 200 kPa) seems therefore too low for bubble splitting to occur, whereas it has been observed at higher pressures (Chomas et al. 2000).”
BackgroundRadial oscillations of encapsulated microbubbles in viscoelastic liquids
Khismatullin, D. B., & Nadim, A. (2002) · Physics of Fluids · doi:10.1063/1.1503353 · Cited by 110 · cited 1×
“To understand the origin of the sound scattered by UCA microbubbles, all existing models have focused on describing the spherical oscillations of coated bubbles (de Jong et al. 1994; Church 1995; Hoff et al. 2000; Khismatullin and Nadim 2002; Sarkar et al. 2005; Marmottant et al. 2005).”
Nonlinear intravascular ultrasound contrast imaging
Goertz, D. E., Frijlink, M. E., de Jong, N., & van der Steen, A. F. W. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.01.001 · Cited by 91 · cited 1×
“Second, for high transmit frequency, it gives a stronger signal than higher harmonics and ultraharmonics (Goertz et al. 2006b) and is less sensitive to attenuation and nonlinear propagation, which makes subharmonic imaging a promising modality for intravascular imaging (Goertz et al. 2006a).”
Optical Micro-Manipulation Using Laguerre-Gaussian Beams
Garbin, V., Cojoc, D., Ferrari, E., Zaccaria, R. P., Cabrini, S., & Fabrizio, E. M. D. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.5773 · Cited by 45 · cited 3×
“…1,064-nm continuous wave Yb fiber laser (YLM, IPG Photonics, Oxford, MA, USA) is converted into a Laguerre-Gaussian mode by a phase diffractive optical element (DOE) (Garbin et al. 2005) implemented on a spatial light modulator (SLM) (X8267–11, Hamamatsu Photonics, Herrsching am Ammersee, Germany).”
Self-citation
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Self-citationRoovers, S., Segers, T., Lajoinie, G., Deprez, J., Versluis, M., De Smedt, S. C., & Lentacker, I. (2019) · Langmuir · doi:10.1021/acs.langmuir.8b03779 · Cited by 256
Self-citationUltrasound Contrast Agent Modeling: A Review
Versluis, M., Stride, E., Lajoinie, G., Dollet, B., & Segers, T. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.014 · Cited by 233
“Despite these simplifications, the results have demonstrated good agreement with experimental observations (Fig. 8b; Dollet et al. 2008; Versluis et al. 2010).”
ResultSelf-citationBubble Dynamics in Soft and Biological Matter
Dollet, B., Marmottant, P., & Garbin, V. (2019) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010518-040352 · Cited by 226
“(d) Nonspherical surface modes displayed by a lipid-coated bubbles under ultrasound (Dollet et al. 2008).”
BackgroundSelf-citation
Metadata
- Authors
- Dollet, B., van der Meer, S. M., Garbin, V., de Jong, N., Lohse, D., & Versluis, M.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2008-09
- Volume
- 34
- Issue
- 9
- Pages
- 1465-1473
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2121883787
- Cited by
- 165
- References
- 16
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.