Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 243

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Ultrasonographic Measurement of the Respiratory Variation in the Inferior Vena Cava Diameter Is Predictive of Fluid Responsiveness in Critically Ill Patients: Systematic Review and Meta-analysis

Open access
Zhang, Zhongheng, Xu, Xiao, Ye, Sheng, Xu, Lei · 2014 · Ultrasound in Medicine & Biology

Abstract

Respiratory variation in the inferior vena cava (ΔIVC) has been extensively studied with respect to its value in predicting fluid responsiveness, but the results are conflicting. This systematic review was aimed at investigating the diagnostic accuracy of ΔIVC in predicting fluid responsiveness. Databases including Medline, Embase, Scopus and Web of Knowledge were searched from inception to May 2013. Studies exploring the diagnostic performance of ΔIVC in predicting fluid responsiveness were included. To allow for more between- and within-study variance, a hierarchical summary receiver operating characteristic model was used to pool the results. Subgroup analyses were performed for patients on mechanical ventilation, spontaneously breathing patients and those challenged with colloids and crystalloids. A total of 8 studies involving 235 patients were eligible for analysis. Cutoff values of ΔIVC varied across studies, ranging from 12% to 40%. The pooled sensitivity and specificity in the overall population were 0.76 (95% confidence interval [CI]: 0.61-0.86) and 0.86 (95% CI: 0.69-0.95), respectively. The pooled diagnostic odds ratio (DOR) was 20.2 (95% CI: 6.1-67.1). The diagnostic performance of ΔIVC appeared to be better in patients on mechanical ventilation than in spontaneously breathing patients (DOR: 30.8 vs. 13.2). The pooled area under the receiver operating characteristic curve was 0.84 (95% CI: 0.79-0.89). Our study indicates that ΔIVC measured with point-of-care ultrasonography is of great value in predicting fluid responsiveness, particularly in patients on controlled mechanical ventilation and those resuscitated with colloids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2013.12.010

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 243

Metadata

Authors
Zhang, Z., Xu, X., Ye, S., & Xu, L.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2014-05
Volume
40
Issue
5
Pages
845-853
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2143300179
Cited by
243
References
5
FWCI
4.12
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonographic Measurement of the Respiratory Variation in the Inferior Vena Cava Diameter Is Predictive of Fluid Responsiveness in Critically Ill Patients: Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2013.12.010
The paper
Zhang, Z., Xu, X., Ye, S., & Xu, L. (2014). Ultrasonographic Measurement of the Respiratory Variation in the Inferior Vena Cava Diameter Is Predictive of Fluid Responsiveness in Critically Ill Patients: Systematic Review and Meta-analysis. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2013.12.010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.