Cited by 13Pregnancy and preeclampsia studiesPrenatal Screening and DiagnosticsUltrasound in Clinical Applications

Comparison of 2-D and 3-D estimates of placental volume in early pregnancy

Aye, Christina Y.L., Stevenson, Gordon N., Impey, Lawrence, Collins, Sally L.·2015·Ultrasound in Medicine & Biology

Abstract

Ultrasound estimation of placental volume (PlaV) between 11 and 13 wk has been proposed as part of a screening test for small-for-gestational-age babies. A semi-automated 3-D technique, validated against the gold standard of manual delineation, has been found at this stage of gestation to predict small-for-gestational-age at term. Recently, when used in the third trimester, an estimate obtained using a 2-D technique was found to correlate with placental weight at delivery. Given its greater simplicity, the 2-D technique might be more useful as part of an early screening test. We investigated if the two techniques produced similar results when used in the first trimester. The correlation between PlaV values calculated by the two different techniques was assessed in 139 first-trimester placentas. The agreement on PlaV and derived "standardized placental volume," a dimensionless index correcting for gestational age, was explored with the Mann-Whitney test and Bland-Altman plots. Placentas were categorized into five different shape subtypes, and a subgroup analysis was performed. Agreement was poor for both PlaV and standardized PlaV (p < 0.001 and p < 0.001), with the 2-D technique yielding larger estimates for both indices compared with the 3-D method. The mean difference in standardized PlaV values between the two methods was 0.007 (95% confidence interval: 0.006-0.009). The best agreement was found for regular rectangle-shaped placentas (p = 0.438 and p = 0.408). The poor correlation between the 2-D and 3-D techniques may result from the heterogeneity of placental morphology at this stage of gestation. In early gestation, the simpler 2-D estimates of PlaV do not correlate strongly with those obtained with the validated 3-D technique.

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2014.10.001

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Assessments of PlaV generated using 2-D ultrasound correlate poorly with validated 3-D ultrasound techniques and are probably less reliable with certain placental shapes, particularly in the first trimester.

    “However, assessments of PlaV generated using 2-D ultrasound correlate poorly with validated 3-D ultrasound techniques and are probably less reliable with certain placental shapes, particularly in the first trimester [34].”
  • The random walker algorithm overcomes limitations of VOCALTM with respect to an irregularly shaped placenta, is less likely to over-estimate placental volume compared with 2-D techniques, and its initialisation is significantly faster compared with VOCAL (p < 0.001).

    “The random walker algorithm overcomes the limitations of VOCAL™ with respect to an irregularly shaped placenta, is less likely to over-estimated placental volume compared with 2-D techniques and its initialisation is significantly faster compared with VOCAL (p = <0.001) [34, 35].”
  • The VOCALTM method is purely geometric and estimation of volume in an irregularly shaped organ may be more prone to error.

    “This method is purely geometric and consequently estimation of volume in an irregularly shaped organ may be more prone to error [35], this is important as it has been demonstrated that the shape of the placenta in the first trimester is not always regular [34].”

The citation lists haven’t been fetched yet

References 26 · Cited by 13

Authors
Aye, C. Y. L., Stevenson, G. N., Impey, L., & Collins, S. L.
Affiliations
  • John Radcliffe Hospital (GB)
  • University of Oxford (GB)
Corresponding author
Aye, Christina Y.L.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2015-03
Volume
41
Issue
3
Pages
734-740
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2065809376
Cited by
13
References
26
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2021: 2 · 2019: 2 · 2018: 2 · 2017: 2 · 2015: 1
FWCI
1.89
Type
journal article
Language
en
Open access
closed
Locations
  • Ultrasound in Medicine & Biology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
Keywords
placental volume, 3D ultrasound, first trimester, placental morphology, measurement agreement, placental weight
MeSH terms
Female, Humans, Infant, Small for Gestational Age, Organ Size, Placenta, Pregnancy, Pregnancy Trimester, First, Pregnancy Trimester, Second, Ultrasonography, Prenatal, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review