The B-Mode Image-Guided Ultrasound Attenuation Parameter Accurately Detects Hepatic Steatosis in Chronic Liver Disease

Fujiwara, Yudai, Kuroda, Hidekatsu, Abe, Tamami, Ishida, Kazuyuki, Oguri, Takuma, Noguchi, Sachiyo, Sugai, Tamotsu, Kamiyama, Naohisa, Takikawa, Yasuhiro · 2018 · Ultrasound in Medicine & Biology

Abstract

The purpose of our study was to evaluate the diagnostic accuracy of the ultrasound-guided attenuation parameter (UGAP) for the detection of hepatic steatosis in comparison with the controlled attenuation parameter (CAP), using histopathology as the reference standard. We prospectively analyzed 163 consecutive chronic liver disease patients who underwent UGAP, CAP, computed tomography and a liver biopsy on the same day between April 2016 and July 2017. Radiofrequency signals corresponding to the images were compensated by the reference signal previously measured from the uniform phantom with known attenuation (0.44 dB/cm/MHz). The attenuation coefficient was calculated from the signals' decay slope. The median attenuation coefficient values in patients with S0 (n = 62), S1 (n = 63), S2 (n = 23) and S3 grade (n = 15) were 0.485, 0.560, 0.660 and 0.720, respectively. Significant correlations were found between attenuation coefficient and percentage steatosis, CAP values and liver-to-spleen computed tomography attenuation ratio (p < 0.001). The areas under the receiver operating characteristic curve of UGAP for identifying ≥S1, ≥S2 and ≥S3 were 0.900, 0.953 and 0.959, respectively, which were significantly better than the results obtained with CAP for identifying ≥S2 and ≥S3. In conclusion, UGAP had high diagnostic accuracy for detecting hepatic steatosis in patients with chronic liver disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2018.06.017

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 159

Metadata

Authors
Fujiwara, Y., Kuroda, H., Abe, T., Ishida, K., Oguri, T., Noguchi, S., Sugai, T., Kamiyama, N., & Takikawa, Y.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2018-11
Volume
44
Issue
11
Pages
2223-2232
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2887582386
Cited by
159
References
5
FWCI
9.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The B-Mode Image-Guided Ultrasound Attenuation Parameter Accurately Detects Hepatic Steatosis in Chronic Liver Disease. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2018.06.017
The paper
Fujiwara, Y., Kuroda, H., Abe, T., Ishida, K., Oguri, T., Noguchi, S., Sugai, T., Kamiyama, N., & Takikawa, Y. (2018). The B-Mode Image-Guided Ultrasound Attenuation Parameter Accurately Detects Hepatic Steatosis in Chronic Liver Disease. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2018.06.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.