The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Removal of carbamazepine from aqueous solution using sono-activated persulfate process
Open accessAbstract
This study investigated systematically the removal of carbamazepine (CBZ) in solution using the combination of ultrasound and persulfate anions to identify the factors affecting the kinetics of the process. The effects of reaction time, initial persulfate anion concentration, initial CBZ concentration, ultrasonic power input, solution pH and temperature on CBZ removal efficiency were examined. The sulfate radical oxidation of CBZ in the presence of ultrasonic irradiation showed a significant synergistic effect on CBZ removal. It is found that up to 89.4% CBZ removal efficiency was achieved after 120 min reaction. The removal process of CBZ in solution could be described using pseudo-first-order kinetics. In this system, sulfate radicals (SO4(-)) were considered to be the mainly oxidant to remove CBZ while ultrasound power input could affect CBZ removal efficiency significantly. Changing solution pH influenced the CBZ removal efficiency and the best performance would be achieved at pH 5.0.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Kolpin, D. W., Furlong, E. T., Meyer, M. T., Thurman, E. M., Zaugg, S. D., Barber, L. B., & Buxton, H. T. (2002) · Environmental Science & Technology · doi:10.1021/es011055j · Cited by 7,953
Thermally activated persulfate (TAP) oxidation of antiepileptic drug carbamazepine in water
Deng, J., Shao, Y., Gao, N., Deng, Y., Zhou, S., & Hu, X. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.05.044 · Cited by 268
Cited by
Wang, J., & Wang, S. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.11.059 · Cited by 4,087
Self-citationFedorov, K., Plata-Gryl, M., Khan, J. A., & Boczkaj, G. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122804 · Cited by 676
Fedorov, K., Dinesh, K., Sun, X., Darvishi Cheshmeh Soltani, R., Wang, Z., Sonawane, S., & Boczkaj, G. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.134191 · Cited by 497
Yin, R., Guo, W., Wang, H., Du, J., Zhou, X., Wu, Q., Zheng, H., Chang, J., & Ren, N. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.063 · Cited by 369
Guerra-Rodríguez, S., Rodríguez, E., Singh, D., & Rodríguez-Chueca, J. (2018) · Water · doi:10.3390/w10121828 · Cited by 365
Metadata
- Authors
- Wang, S., & Zhou, N.
- Venue
- Ultrasonics Sonochemistry
- Publisher
- Elsevier BV
- Published
- 2016-03
- Volume
- 29
- Pages
- 156-162
- ISSN
- 1350-4177 (ISSN-L)
- OpenAlex
- W1826196581
- Cited by
- 202
- References
- 3
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Removal of carbamazepine from aqueous solution using sono-activated persulfate process. https://app.cochat.ai/papers/10.1016/j.ultsonch.2015.09.008
- The paper
- Wang, S., & Zhou, N. (2016). Removal of carbamazepine from aqueous solution using sono-activated persulfate process. Ultrasonics Sonochemistry. https://doi.org/10.1016/j.ultsonch.2015.09.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.