Dependence of cavitation, chemical effect, and mechanical effect thresholds on ultrasonic frequency
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Cavitation, chemical effect, and mechanical effect thresholds were investigated in wide frequency ranges from 22 to 4880kHz. Each threshold was measured in terms of sound pressure at fundamental frequency. Broadband noise emitted from acoustic cavitation bubbles was detected by a hydrophone to determine the cavitation threshold. Potassium iodide oxidation caused by acoustic cavitation was used to quantify the chemical effect threshold. The ultrasonic erosion of aluminum foil was conducted to estimate the mechanical effect threshold. The cavitation, chemical effect, and mechanical effect thresholds increased with increasing frequency. The chemical effect threshold was close to the cavitation threshold for all frequencies. At low frequency below 98kHz, the mechanical effect threshold was nearly equal to the cavitation threshold. However, the mechanical effect threshold was greatly higher than the cavitation threshold at high frequency. In addition, the thresholds of the second harmonic and the first ultraharmonic signals were measured to detect bubble occurrence. The threshold of the second harmonic approximated to the cavitation threshold below 1000kHz. On the other hand, the threshold of the first ultraharmonic was higher than the cavitation threshold below 98kHz and near to the cavitation threshold at high frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of ultrasound in food technology: Processing, preservation and extraction
Chemat, F., Zill-e-Huma, & Khan, M. K. (2011) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2010.11.023 · Cited by 2,533
The Chemical Effects of Ultrasound
Suslick, K. S. (1989) · Scientific American · doi:10.1038/scientificamerican0289-80 · Cited by 1,021
A standard method to calibrate sonochemical efficiency of an individual reaction system
Koda, S., Kimura, T., Kondo, T., & Mitome, H. (2003) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(03)00084-1 · Cited by 778
Self-citationNeppiras, E. A. (1980) · Physics Reports · doi:10.1016/0370-1573(80)90115-5 · Cited by 775
Wiley encyclopedia of electrical and electronics engineering
(1999) · Choice Reviews Online · doi:10.5860/choice.37-1289 · Cited by 696
Ultrasound-assisted crystallization (sonocrystallization)
Luque de Castro, M. D., & Priego-Capote, F. (2007) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2006.12.004 · Cited by 590
Ultrasonics in food processing
Chandrapala, J., Oliver, C., Kentish, S., & Ashokkumar, M. (2012) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2012.01.010 · Cited by 389
Standardization of ultrasonic power for sonochemical reaction
Kimura, T., Sakamoto, T., Leveque, J.-M., Sohmiya, H., Fujita, M., Ikeda, S., & Ando, T. (1996) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(96)00021-1 · Cited by 385
Impact of Ultrasonic Frequency on Aqueous Sonoluminescence and Sonochemistry
Beckett, M. A., & Hua, I. (2001) · The Journal of Physical Chemistry A · doi:10.1021/jp003226x · Cited by 353
Pétrier, C., & Francony, A. (1997) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(97)00036-9 · Cited by 330
Cited by
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Ding, Y., Ma, H., Wang, K., Azam, S. M. R., Wang, Y., Zhou, J., & Qu, W. (2021) · LWT · doi:10.1016/j.lwt.2021.111320 · Cited by 81
Metadata
- Authors
- Thanh Nguyen, T., Asakura, Y., Koda, S., & Yasuda, K.
- Venue
- Ultrasonics Sonochemistry
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 39
- Pages
- 301-306
- ISSN
- 1350-4177 (ISSN-L)
- OpenAlex
- W2608619052
- Cited by
- 225
- References
- 20
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.