CoChat

Geometric and operational optimization of 20-kHz probe-type sonoreactor for enhancing sonochemical activity

Son, Younggyu, No, Yunsung, Kim, Jeonggwan · 2020 · Ultrasonics Sonochemistry
Cited by 74

The DOI matches its Crossref record.

Abstract

The use of a 20-kHz probe-type sonicator irradiating downward in a 500 mL vessel was optimized for the enhancement of the sonochemical activity in terms of the geometric and operational factors. These factors included the probe immersion depth (the vertical position of the probe), input power, height of the liquid from the bottom, horizontal position of the probe, and thickness of bottom plate The sonochemical oxidation reactions were investigated both quantitatively and qualitatively using calorimetry, KI dosimetry, and luminol (Sonochemiluminescence, SCL) techniques. The sonochemical activity was very positively affected by the vertical boundaries. The highest sonochemical activity was obtained when the probe was placed close to the bottom of the vessel (immersion depth of 60 mm), with a high input power (input power of 75%), and optimal liquid height condition (liquid height of 70 mm). The SCL image analysis showed that the cavitational activity zone gradually expanded around the probe body and changed into a circular shape as the experimental conditions were optimized, and consequently the sonochemical activity increased. The formation of a large bright circular-shaped activity zone could be attributed to the strong reflections of the ultrasound firstly, at the vessel bottom and secondly, at the liquid surface. On the other hand, the cavitational activity zone and the sonochemical activity were negatively affected by the horizontal boundaries when the probe was placed close to the side wall of the vessel. In addition, it was found that the sonochemical activity was also significantly affected by the thickness of the support plate owing to the reflection and transmission of the ultrasound at the boundary between the liquid and the solid media.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultsonch.2020.105065

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. McMurray, 1999, Mechanistic and spatial study of ultrasonically induced luminol chemiluminescence, J. Phys. Chem. A, 103, 3955, 10.1021/jp984503r · DOI
  2. Price, 2010, Direct observation of cavitation fields at 23 and 515kHz, Ultrason. Sonochem., 17, 30, 10.1016/j.ultsonch.2009.04.009 · DOI
  3. Rooze, 2011, Effect of resonance frequency, power input, and saturation gas type on the oxidation efficiency of an ultrasound horn, Ultrason. Sonochem., 18, 209, 10.1016/j.ultsonch.2010.05.007 · doi:10.1016/j.ultsonch.2010.05.007
  4. Klíma, 2007, Optimisation of 20kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results, Ultrason. Sonochem., 14, 19, 10.1016/j.ultsonch.2006.01.001 · DOI · Paper page
  5. No, 2019, Effects of probe position of 20 kHz sonicator on sonochemical oxidation activity, Jpn. J. Appl. Phys. 58, SGGD02, 10.7567/1347-4065/ab0adb · doi:10.7567/1347-4065/ab0adb
  6. Mohod, 2011, Ultrasonic degradation of polymers: Effect of operating parameters and intensification using additives for carboxymethyl cellulose (CMC) and polyvinyl alcohol (PVA), Ultrason. Sonochem., 18, 727, 10.1016/j.ultsonch.2010.11.002 · DOI · Paper page
  7. Nishida, 2004, Precipitation of calcium carbonate by ultrasonic irradiation, Ultrason. Sonochem., 11, 423, 10.1016/j.ultsonch.2003.09.003 · DOI
  8. Sun, 2010, Stability of all-trans-β-carotene under ultrasound treatment in a model system: Effects of different factors, kinetics and newly formed compounds, Ultrason. Sonochem., 17, 654, 10.1016/j.ultsonch.2009.12.005 · DOI
  9. Petrier, 1994, Sonochemical degradation of phenol in dilute aqueous solutions: comparison of the reaction rates at 20 and 487 kHz, J. Phys. Chem., 98, 10514, 10.1021/j100092a021 · DOI · Paper page
  10. Ge, 2019, Ultrasonic cavitation noise in suspensions with ethyl cellulose nanoparticles, J. Appl. Phys., 125, 10.1063/1.5099937 · doi:10.1063/1.5099937
  11. Kojima, 2014, Physical and chemical characteristics of ultrasonically-prepared water-in-diesel fuel: Effects of ultrasonic horn position and water content, Ultrason. Sonochem., 21, 722, 10.1016/j.ultsonch.2013.09.019 · doi:10.1016/j.ultsonch.2013.09.019
  12. Sun, 2011, Effects of different factors of ultrasound treatment on the extraction yield of the all-trans-β-carotene from citrus peels, Ultrason. Sonochem., 18, 243, 10.1016/j.ultsonch.2010.05.014 · DOI · Paper page
  13. Fukunaga, 2019, Effect of geometrical configuration of reactor on a ZrP nano-dispersion process using ultrasonic irradiation, Ultrason. Sonochem., 52, 157, 10.1016/j.ultsonch.2018.11.008 · DOI
  14. Han, 2014, Extremely efficient liquid exfoliation and dispersion of layered materials by unusual acoustic cavitation, Sci. Rep., 4, 5133, 10.1038/srep05133 · DOI
  15. Son, 2017, Simple design strategy for bath-type high-frequency sonoreactors, Chem. Eng. J., 328, 654, 10.1016/j.cej.2017.07.012 · doi:10.1016/j.cej.2017.07.012
  16. Son, 2011, Geometric optimization of sonoreactors for the enhancement of sonochemical activity, J. Phys. Chem. C, 115, 4096, 10.1021/jp110319y · DOI
  17. Lim, 2014, The effects of liquid height/volume, initial concentration of reactant and acoustic power on sonochemical oxidation, Ultrason. Sonochem., 21, 1988, 10.1016/j.ultsonch.2014.03.005 · DOI
  18. Khuyen Viet Bao, 2013, Influence of liquid height on mechanical and chemical effects in 20 kHz sonication, Jpn. J. Appl. Phys., 52, 07HE07, 10.7567/JJAP.52.07HE07 · doi:10.7567/jjap.52.07he07
  19. Asakura, 2008, Effects of ultrasonic frequency and liquid height on sonochemical efficiency of large-scale sonochemical reactors, Ultrason. Sonochem., 15, 244, 10.1016/j.ultsonch.2007.03.012 · DOI · Paper page
  20. Asakura, 2010, Optimization of sonochemical reactors by measuring impedance of transducer and sound pressure in solution, J. Chem. Eng. Jpn., 43, 1008, 10.1252/jcej.10we158 · doi:10.1252/jcej.10we158
  21. Son, 2009, Liquid height effect on sonochemical reactions in a 35 kHz sonoreactor, Jpn. J. Appl. Phys., 48, 07GM16, 10.1143/JJAP.48.07GM16 · DOI
  22. Wood, 2017, A parametric review of sonochemistry: Control and augmentation of sonochemical activity in aqueous solutions, Ultrason. Sonochem., 38, 351, 10.1016/j.ultsonch.2017.03.030 · DOI · Paper page
  23. Lee, 2011, Development and optimization of acoustic bubble structures at high frequencies, Ultrason. Sonochem., 18, 92, 10.1016/j.ultsonch.2010.03.004 · doi:10.1016/j.ultsonch.2010.03.004
  24. Tiong, 2017, Comparison of sonochemiluminescence images using image analysis techniques and identification of acoustic pressure fields via simulation, Ultrason. Sonochem., 36, 78, 10.1016/j.ultsonch.2016.11.003 · DOI
  25. Wei, 2015, Designing and characterizing a multi-stepped ultrasonic horn for enhanced sonochemical performance, Ultrason. Sonochem., 27, 325, 10.1016/j.ultsonch.2015.05.013 · DOI
  26. Ashokkumar, 2009, The detection and control of stable and transient acoustic cavitation bubbles, Phys. Chem. Chem. Phys., 11, 10118, 10.1039/b915715h · DOI
  27. Sivakumar, 2001, Ultrasound enhanced degradation of Rhodamine B: optimization with power density, Ultrason. Sonochem., 8, 233, 10.1016/S1350-4177(01)00082-7 · DOI · Paper page
  28. Kang, 1999, Sonolytic destruction of methyl tert-butyl ether by ultrasonic irradiation: the role of O3, H2O2, frequency, and power density, Environ. Sci. Technol., 33, 3199, 10.1021/es9810383 · DOI · Paper page
  29. Kojima, 2010, The effects of acoustic flow and mechanical flow on the sonochemical efficiency in a rectangular sonochemical reactor, Ultrason. Sonochem., 17, 978, 10.1016/j.ultsonch.2009.11.020 · DOI
  30. Choi, 2019, Enhancement of sonochemical oxidation reactions using air sparging in a 36 kHz sonoreactor, Ultrason. Sonochem., 51, 412, 10.1016/j.ultsonch.2018.07.032 · DOI
  31. Henglein, 1989, Luminescence and chemical action by pulsed ultrasound, J. Am. Chem. Soc., 111, 1974, 10.1021/ja00188a004 · doi:10.1021/ja00188a004
  32. Little, 2007, The effect of solution level on calorific and dosimetric results in a 70 kHz tower type sonochemical reactor, Ultrason. Sonochem., 14, 375, 10.1016/j.ultsonch.2006.07.009 · doi:10.1016/j.ultsonch.2006.07.009
  33. Son, 2012, Acoustic emission spectra and sonochemical activity in a 36 kHz sonoreactor, Ultrason. Sonochem., 19, 16, 10.1016/j.ultsonch.2011.06.001 · doi:10.1016/j.ultsonch.2011.06.001
  34. Yasui, 2007, FEM calculation of an acoustic field in a sonochemical reactor, Ultrason. Sonochem., 14, 605, 10.1016/j.ultsonch.2006.09.010 · DOI
  35. Saito, 2015, Chapter 2 – Ultrasound field and bubbles, 11

Cited by

Metadata

Authors
Son, Y., No, Y., & Kim, J.
Venue
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Published
2020-07
Volume
65
Pages
105065
ISSN
1350-4177
Cited by
74
References
0
Language
en
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
National Research Foundation of Korea

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.