A review on pharmaceuticals removal from waters by single and combined biological, membrane filtration and ultrasound systems
Open accessThe DOI matches its Crossref record; 175 of the 175 references it cites were found in a registry or an index.
Abstract
Contaminants of emerging concern (CEC) such as pharmaceuticals commonly found in urban and industrial wastewater are a potential threat to human health and have negative environmental impact. Most wastewater treatment plants cannot efficiently remove these compounds and therefore, many pharmaceuticals end up in aquatic ecosystems, inducing problems such as toxicity and antibiotic-resistance. This review reports the extent of pharmaceutical removal by individual processes such as bioreactors, advanced oxidation processes and membrane filtration systems, all of which are not 100% efficient and can lead to the direct discharge of pharmaceuticals into water bodies. Also, the importance of understanding biotransformation of pharmaceutical compounds during biological and ultrasound treatment, and its impact on treatment efficacy will be reviewed. Different combinations of the processes above, either as an integrated configuration or in series, will be discussed in terms of their degradation efficiency and scale-up capabilities. The trace quantities of pharmaceutical compounds in wastewater and scale-up issues of ultrasound highlight the importance of membrane filtration as a concentration and volume reduction treatment step for wastewater, which could subsequently be treated by ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pharmaceuticals and personal care products in the environment: agents of subtle change?
Daughton, C. G., & Ternes, T. A. (1999) · Environmental Health Perspectives · doi:10.1289/ehp.99107s6907 · Cited by 4,705
Luo, Y., Guo, W., Ngo, H. H., Nghiem, L. D., Hai, F. I., Zhang, J., Liang, S., & Wang, X. C. (2014) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.12.065 · Cited by 3,983 · cited 2×
“Current water treatment methods implemented in WWTPs are inefficient for the complete removal of most pharmaceuticals [2,5], leading to the discharge of these compounds directly into water bodies.”
BackgroundHydrogen Peroxide Synthesis: An Outlook beyond the Anthraquinone Process
Campos‐Martin, J. M., Blanco‐Brieva, G., & Fierro, J. L. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503779 · Cited by 3,238
Evaluation of advanced oxidation processes for water and wastewater treatment – A critical review
Miklos, D. B., Remy, C., Jekel, M., Linden, K. G., Drewes, J. E., & Hübner, U. (2018) · Water Research · doi:10.1016/j.watres.2018.03.042 · Cited by 3,050 · cited 7×
“Advanced oxidation processes (AOPs) are alternative treatments capable of producing and utilizing radical species (such as HO•) to degrade CEC [24].”
BackgroundInfluentialOller, I., Malato, S., & Sánchez-Pérez, J. A. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.08.061 · Cited by 2,406 · cited 2×
“However, it is important to mention that photochemical AOPs such as photo-Fenton, UVC/H2O2 and UVC/Persulphate have some drawbacks such as iron precipitation, UVC-lamps fouling and the need to store and transport hydrogen peroxide or persulphate [26].”
BackgroundMichael, I., Rizzo, L., McArdell, C. S., Manaia, C. M., Merlin, C., Schwartz, T., Dagot, C., & Fatta-Kassinos, D. (2013) · Water Research · doi:10.1016/j.watres.2012.11.027 · Cited by 2,013 · cited 1×
“Current water treatment methods implemented in WWTPs are inefficient for the complete removal of most pharmaceuticals [2,5], leading to the discharge of these compounds directly into water bodies.”
BackgroundBiological Wastewater Treatment
Grady Jr., C. P. L., Daigger, G. T., Love, N. G., & Filipe, C. D. M. (2011) · CRC Press eBooks · doi:10.1201/b13775 · Cited by 1,767
Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant
Carballa, M., Omil, F., Lema, J. M., Llompart, M., Garcı́a-Jares, C., Rodrı́guez, I., Gómez, M., & Ternes, T. (2004) · Water Research · doi:10.1016/j.watres.2004.03.029 · Cited by 1,556
Ahmed, M. B., Zhou, J. L., Ngo, H. H., Guo, W., Thomaidis, N. S., & Xu, J. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2016.04.045 · Cited by 1,310 · cited 1×
“paper [39-44] or integrated into a more general analysis on advanced oxidation processes [9,45-47], however there is very little literature”
BackgroundRadjenović, J., Petrović, M., & Barceló, D. (2009) · Water Research · doi:10.1016/j.watres.2008.11.043 · Cited by 1,224 · cited 3×
“treatment methods have shown > 90% removal in COD, BOD, N and P [52,53], they are not that effective at removing CEC such as pharmaceuticals [4,22,54,55].”
BackgroundMethod
Cited by
Samal, K., Mahapatra, S., & Hibzur Ali, M. (2022) · Energy Nexus · doi:10.1016/j.nexus.2022.100076 · Cited by 778
A review on conventional and advanced hybrid technologies for pharmaceutical wastewater treatment
Eniola, J. O., Kumar, R., Barakat, M. A., & Rashid, J. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.131826 · Cited by 306
Ultrasound-induced changes in the structure and functionality of starch and protein
Zhu, M., Xiong, W., Devkota, L., & Dhital, S. (2026) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2025.112111 · Cited by 40
Metadata
- Authors
- Alfonso-Muniozguren, P., Serna-Galvis, E. A., Bussemaker, M., Torres-Palma, R. A., & Lee, J.
- Venue
- Ultrasonics Sonochemistry
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 76
- Pages
- 105656
- ISSN
- 1350-4177 (ISSN-L)
- OpenAlex
- W3176436616
- Cited by
- 203
- References
- 175
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.