Cited by 81Bacterial Identification and Susceptibility TestingAnalytical Methods in Pharmaceuticalsbioluminescence and chemiluminescence research

Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products

Parveen, Seema, Kaur, Simleen, David, Selwyn A. Wilson, Kenney, James L., McCormick, William M., Gupta, Rajesh K.·2011·Vaccine

Abstract

Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter ) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard…

Integrity signals

Registry

Crossref · 10.1016/j.vaccine.2011.08.055

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • As therapies move beyond phase I trials, meeting requirements for a strictly controlled environment becomes more costly and time-consuming.

    “As these therapies move beyond phase I trials, meeting these requirements becomes more costly and time-consuming (129,130).”

Cited by

Sorted by citations

Authors
Parveen, S., Kaur, S., David, S. A. W., Kenney, J. L., McCormick, W. M., & Gupta, R. K.
Affiliations
Center for Biologics Evaluation and Research (US)
Venue
Vaccine
Publisher
Elsevier BV
Published
2011-10
Volume
29
Issue
45
Pages
8012-8023
ISSN
0264-410X (ISSN-L)
OpenAlex
W1971981576
Cited by
81
References
0
Citations by year
2026: 3 · 2025: 7 · 2024: 8 · 2023: 8 · 2022: 3 · 2021: 8 · 2020: 3 · 2019: 5 · 2018: 4 · 2017: 7 · 2016: 7 · 2015: 4 · 2014: 6 · 2013: 7 · 2012: 1
FWCI
2.68
Type
journal article
Language
en
Open access
closed
Locations
  • Vaccine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
Keywords
rapid microbiological methods, sterility testing, vaccines, biological products, ATP bioluminescence, CO2 monitoring, BacT/Alert, BACTEC, membrane filtration, detection sensitivity, detection time, inactivated influenza vaccine, spore-forming bacteria, anaerobic bacteria
MeSH terms
Adenosine Triphosphate, Bacteria, Biological Products, Carbon Dioxide, Chemistry Techniques, Analytical, Drug Contamination, Fungi, Microbiological Techniques, Sensitivity and Specificity, Technology, Pharmaceutical, Vaccines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›