Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

Characteristics of saccadic intrusions

Open access
Abadi, R.V., Gowen, E. · 2004 · Vision Research

Abstract

Primary fixation is never perfectly stable, but is frequently interrupted by slow drifts, microsaccades and saccadic intrusions (SI). SI are involuntary, conjugate movements which take the form of an initial fast movement away from the desired eye position and followed after a short duration, by either a return secondary saccade or a drift. The purpose of this study was to examine the prevalence and metrics of SI in a population of 50 healthy subjects. Using both one and two dimensional recordings we find that all 50 members of the subject group exhibited SI. The SI were bilateral, conjugate and horizontal. No purely vertical SI were detected when examined in three subjects. SI amplitude mean and range was 0.6 degrees +/-0.5 degrees, 0.1 degrees -4.1 degrees; SI frequency mean and range was 18.0+/-14.3 per min, 1.0-54.8 per min; SI duration mean and range was 225+/-150, 20-870 ms. The mean SI amplitude and frequency when SI<0.5 degrees were removed was 0.97 degrees +/-0.56 degrees and 7.0+/-11.4 per min respectively. Age was positively correlated with SI amplitude (p<0.01), but there was no correlation between age and SI frequency. Three of four types of SI monophasic square wave intrusions (MSWI), biphasic square wave intrusions (BSWI) and double saccadic pulses (DSP) were found to be exclusively saccadic, whilst the fourth type, the single saccadic pulses (SSP), were confirmed to exhibit a slow secondary component. MSWI were the most frequently observed SI occurring in 47 out of 50 (94%) of the subjects with a mean amplitude, frequency and duration of 0.7 degrees +/-0.5 degrees, 11.5+/-11.6 per min, and 255+/-147 ms respectively. Mean amplitudes and frequencies for BSWI (n=20), SSP (n=11) and DSP (n=34) were found to be 0.50 degrees +/-0.2 degrees, 1.2+/-2.5 per min; 0.40 degrees +/-0.20 degrees, 0.4+/-1.0 per min and 0.3 degrees +/-0.4 degrees, 5.0+/-8.7 per min respectively. No differences in MSWI characteristics were found between binocular and monocular viewing. Possible explanations for SI occurrence include experimental viewing conditions, subject fatigue and covert shifts in attention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.visres.2004.05.009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Abadi, R. V., & Gowen, E.
Venue
Vision Research
Publisher
Elsevier BV
Published
2004-10
Volume
44
Issue
23
Pages
2675-2690
ISSN
0042-6989 (ISSN-L)
OpenAlex
W2142350105
Cited by
161
References
0
FWCI
9.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics of saccadic intrusions. https://app.cochat.ai/papers/10.1016/j.visres.2004.05.009
The paper
Abadi, R. V., & Gowen, E. (2004). Characteristics of saccadic intrusions. Vision Research. https://doi.org/10.1016/j.visres.2004.05.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.