Highly efficient electro-generation of H2O2 by adjusting liquid-gas-solid three phase interfaces of porous carbonaceous cathode during oxygen reduction reaction
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Equilibrium of three reactants (oxygen, proton and electron) in oxygen reduction reaction at large current flux is necessary for highly efficient electro-generation of H2O2. In this work, we investigated reactants equilibrium and H2O2 electrochemical production in liquid-gas-solid three phase interfaces on rolling cathodes with high electroactive area. Electrocatalytic reaction accelerated the electrolyte intrusion into hydrophobic porous catalyst layer for higher electroactive surface area, resulting in a 21% increase of H2O2 yield at 15 mA cm-2. Air aerated cathode submerged in air/O2 aeration solution was unable to produce H2O2 efficiently due to the lack of O2 in three phase interfaces (TPIs), especially at current density > 2.5 mA cm-2. For air breathing cathode, stable TPIs inside the active sites was created by addition of gas diffusion layer, to increase H2O2 production from 11 ± 2 to 172 ± 11 mg L-1 h-1 at 15 mA cm-2. Pressurized air flow application enhanced both oxygen supply and H2O2 departure transfer to obtain a high H2O2 production of 461 ± 11 mg L-1 h-1 with CE of 89 ± 2% at 35 mA cm-2, 45% higher than passive gas transfer systems. Our findings provided a new insight of carbonaceous air cathode performance in producing H2O2, providing important information for the practical application and amplification of cathodes in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437
Electrochemical Advanced Oxidation Processes: Today and Tomorrow. A Review
Sirés, I., Brillas, E., Oturan, M. A., Rodrigo, M. A., & Panizza, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2783-1 · Cited by 1,943
Cited by
Zhang, Q., Zhou, M., Ren, G., Li, Y., Li, Y., & Du, X. (2020) · Nature Communications · doi:10.1038/s41467-020-15597-y · Cited by 639
Metadata
- Authors
- An, J., Li, N., Zhao, Q., Qiao, Y., Wang, S., Liao, C., Zhou, L., Li, T., Wang, X., & Feng, Y.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 164
- Pages
- 114933
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2965873868
- Cited by
- 188
- References
- 2
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly efficient electro-generation of H2O2 by adjusting liquid-gas-solid three phase interfaces of porous carbonaceous cathode during oxygen reduction reaction. https://app.cochat.ai/papers/10.1016/j.watres.2019.114933
- The paper
- An, J., Li, N., Zhao, Q., Qiao, Y., Wang, S., Liao, C., Zhou, L., Li, T., Wang, X., & Feng, Y. (2019). Highly efficient electro-generation of H2O2 by adjusting liquid-gas-solid three phase interfaces of porous carbonaceous cathode during oxygen reduction reaction. Water Research. https://doi.org/10.1016/j.watres.2019.114933
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.