Selection of settings of the PID controller by automatic tuning at the control system of the hydraulic fatigue stand
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The linear control algorithms, which are developed using conventional PID [11-14] or feedback linearization techniques [15,16], are simple and easy to implement in engineering. However, they only perform well under certain operating conditions, and fail to achieve satisfactory performance in the presence of aforementioned uncertainties, including parameter permutations, nonlinearities and disturb”
From Compensation Function Observer-Based Backstepping Sliding-Mode Control of Uncertain Electro-Hydraulic Servo System (2024) · cites this paper as [13]
Citations
Cites
Automatic tuning of simple regulators with specifications on phase and amplitude margins
Åström, K. J., & Hägglund, T. (1984) · Automatica · doi:10.1016/0005-1098(84)90014-1 · Cited by 1,834
Industrial adaptive controllers based on frequency response techniques
Hägglund, T. J., & Åström, K. J. (1991) · Automatica · doi:10.1016/0005-1098(91)90052-4 · Cited by 199
Łagoda, T., Macha, E., & Będkowski, W. (1999) · International Journal of Fatigue · doi:10.1016/s0142-1123(99)00003-1 · Cited by 141
Self-citation
Research works printed but not linked: 1
- J. Słowik, L. Kasprzyczak, E. Macha, Mechatronic system for fatigue strength investigation of materials, Hydraulika i Pneumatyka, 1/2006, pp. 27–31 (in Polish).
Cited by
Feng, H., Song, Q., Ma, S., Ma, W., Yin, C., Cao, D., & Yu, H. (2022) · ISA Transactions · doi:10.1016/j.isatra.2021.12.044 · Cited by 230
Coelho, L. D. S., & Cunha, M. A. B. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.04.004 · Cited by 47
Digital control systems based on Matlab/Simulink software for strength machines
Macha, E., Kasprzyczak, L., & Mirek, G. (2011) · Journal of Vibration and Control · doi:10.1177/1077546311403865 · Cited by 20
“From the tests described in (Kasprzyczak and Macha, 2006, 2008, 2010b) it appears that the system with a PI_D controller (i.e. the PI units connected with the control error e and the unit D connected with the object output y – Figure 4) keeps the given loading amplitude in the most precise way…”
BackgroundMethodInfluentialSelf-citationReview of Research on Improved PID Control in Electro-hydraulic Servo System
Li, J., Li, W., Liang, H., & Kong, L. (2023) · Recent Patents on Engineering · doi:10.2174/1872212117666230210090351 · Cited by 15
Kasprzyczak, L., Macha, E., & Marciniak, Z. (2013) · Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena · doi:10.4028/www.scientific.net/ssp.198.489 · Cited by 13
Self-citation
Metadata
- Authors
- Kasprzyczak, L., & Macha, E.
- Affiliations
- Opole University of Technology (PL)
- Corresponding author
- Kasprzyczak, Leszek
- ORCID
- Kasprzyczak, Leszek
- Venue
- Mechanical Systems and Signal Processing
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 22
- Issue
- 6
- Pages
- 1274-1288
- ISSN
- 0888-3270 (ISSN-L)
- OpenAlex
- W2033162404
- Cited by
- 27
- References
- 4
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 4 · 2012: 1
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Mechanical Systems and Signal Processing (publishedVersion)
- Funders
- European Social Fund
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Physical Sciences › Engineering › Mechanical Engineering › Hydraulic and Pneumatic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Algorithms and Applications
- Keywords
- PID controller tuning, automatic controller tuning, controller settings
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selection of settings of the PID controller by automatic tuning at the control system of the hydraulic fatigue stand. https://app.cochat.ai/papers/10.1016/j.ymssp.2007.08.014
- The paper
- Kasprzyczak, L., & Macha, E. (2008). Selection of settings of the PID controller by automatic tuning at the control system of the hydraulic fatigue stand. Mechanical Systems and Signal Processing. https://doi.org/10.1016/j.ymssp.2007.08.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.