Artifacts in portable electrocardiographic monitoring
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
The development of portable ECG monitoring techniques has brought with it new insights into the electrical activity of the heart, and new problems in interpretation of artifacts. This article summarizes and classifies 15 different types of artifacts observed from dynamic electrocardiography. The artifacts appear partly as pseudo-arrhythmias mimicking supraventricular, ventricular, junctional, and dissociative rhythms. There are also non-arrhythmic artifacts which can be misleading in the interpretation of Q-waves, S-T-segments, and T-waves. Eight of the 15 artifacts have potentially serious consequences if not understood, and in 2 instances an artifact almost led to the unnecessary implantation of an artificial cardiac pacemaker.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A second group of artifacts is probably related to intermittent impairment of electrode contact or recorder problems in older recording systems that can result in tape slowing or intermittent stoppage”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Krasnow & Bloomfield, 1976
In the citing paper
“Errors of commission include, but are not confined to, recommending the wrong medication or potentially harmful and unnecessary interventional procedures such as cardiac catheterization, electrophysiological study, or implantation of arrhythmia devices (Krasnow & Bloomfield, 1976).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Krasnow & Bloomfield, 1976
In the citing paper
“AECG signal recording artifacts persist with the newer electrodes, especially those due to motion and impaired skin-electrode interface”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Krasnow & Bloomfield, 1976
Citations
The citation lists are queued
They are fetched later and appear here then.
References 20 · Cited by 81
Metadata
- Authors
- Krasnow, A. Z., & Bloomfield, D. K.
- Corresponding author
- Bloomfield, D.K.
- Venue
- American Heart Journal
- Publisher
- Elsevier BV
- Published
- 1976-03
- Volume
- 91
- Issue
- 3
- Pages
- 349-357
- ISSN
- 0002-8703 (ISSN-L)
- OpenAlex
- W1992879945
- Cited by
- 81
- References
- 20
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 2 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 1
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- American Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- ECG artifacts, dynamic electrocardiography, artifact classification, pacemaker implantation, cardiac rhythm interpretation
- MeSH terms
- Arrhythmias, Cardiac, Diagnostic Errors, Electrocardiography, Humans, Monitoring, Physiologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artifacts in portable electrocardiographic monitoring. https://app.cochat.ai/papers/10.1016/s0002-8703(76)80220-7
- The paper
- Krasnow, A. Z., & Bloomfield, D. K. (1976). Artifacts in portable electrocardiographic monitoring. American Heart Journal. https://doi.org/10.1016/s0002-8703(76)80220-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.