Long-term outcome of patients with syncope associated with coronary artery disease and a nondiagnostic electrophysiologic evaluation
Abstract
Syncope in the patient with structural heart disease and a nondiagnostic noninvasive workup is a generally accepted indication for an invasive electrophysiologic study. However, if the electrophysiologic evaluation is not highly sensitive, arrhythmic causes of syncope may not be discovered. In these patients, recurrent syncope and even sudden death may be observed at follow-up. Thus, we evaluated long-term follow-up in 68 consecutive patients who presented with syncope, coronary artery disease, and who had a negative invasive electrophysiologic evaluation. At a mean follow-up of 30 +/- 18 months (range 1 to 65), there have been 2 sudden deaths and 1 episode each of ventricular fibrillation and ventricular tachycardia in patients treated with an implantable cardioverter-defibrillator. All 4 arrhythmias occurred in patients with left ventricular fractions < or = 25%. Seventeen patients had recurrent presyncope or syncope. Bradycardia causing syncope was found in 8 of these patients. A bundle branch block at the initial evaluation predicted for the occurrence of bradycardia at follow-up. We conclude that in patients with coronary artery disease and syncope, noninducibility at electrophysiologic study predicts a lower risk of sudden death and ventricular arrhythmias. However, in patients with a reduced ejection fraction, the risk of sudden death and ventricular arrhythmias remains up to 10%/year and these patients may warrant treatment with implantable cardioverter-defibrillators. Recurrent syncope is common, and frequently a bradyarrhythmia is found to be the cause. Treatment of selected patients (especially those with bundle branch blocks) with permanent pacemakers may be justified.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The absence of induction of ventricular arrhythmias identifies a group at lower risk of arrhythmic syncope.
“The absence of induction of ventricular arrhythmias identifies a group at lower risk of arrhythmic syncope. 219”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [219]
The lack of an inducible sustained monomorphic VT predicts lower risk of spontaneous VT and better prognosis.
“The lack of an inducible sustained monomorphic VT predicts lower risk of spontaneous VT and better prognosis (192).”
From 2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope (2017) · cites this paper as [192]
The citation lists haven’t been fetched yet
References 30 · Cited by 52
- Authors
- Link, M. S., Kim, K.-M. S., Homoud, M. K., Estes, N. A. M., & Wang, P. J.
- Affiliations
- Tufts University (US)
- Corresponding author
- Link, Mark S
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1999-05
- Volume
- 83
- Issue
- 9
- Pages
- 1334-1337
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W1964564664
- Cited by
- 52
- References
- 30
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2020: 2 · 2018: 5 · 2017: 4 · 2016: 1 · 2014: 1 · 2013: 4 · 2012: 1
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- syncope, coronary artery disease, sudden cardiac death, ventricular arrhythmias, ventricular fibrillation, ventricular tachycardia, implantable cardioverter-defibrillator, left ventricular ejection fraction, bundle branch block, bradycardia, recurrent syncope, long-term follow-up, permanent pacemaker
- MeSH terms
- Adult, Aged, Aged, 80 and over, Bradycardia, Bundle-Branch Block, Coronary Disease, Electrocardiography, Female, Follow-Up Studies, Humans, Male, Middle Aged, Pacemaker, Artificial, Prognosis, Retrospective Studies, Sensitivity and Specificity, Syncope, Life Tables
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review