The DOI matches its OpenAlex record.
Comparison of endoscopic ultrasound-guided fine needle aspiration for focal pancreatic lesions in patients with normal parenchyma and chronic pancreatitis
Abstract
OBJECTIVES: The clinical value of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of pancreatic lesions is uncertain in patients with normal parenchyma and chronic pancreatitis. The aim of this study was to analyze the diagnostic yield and influence of EUS-FNA on the clinical management of patients with pancreatic lesions, in the presence (CP) or absence (NP) of chronic pancreatitis. METHODS: A total of 207 consecutive patients with NP (n = 133) and CP (n = 74) were examined using linear array echo endoscopes for the procedure and 22-gauge needles. RESULTS: Adequate specimens were obtained from 200 lesions. A correct final diagnosis was established at histology (n = 108), bacteriology (n = 9), and clinical follow-up (n = 83). Cytology gave 17 false-negative EUS-FNA results (overall sensitivity: 85%). In patients with NP, 60 solid adenocarcinomas were detected, 32 other malignancies, and 38 benign lesions, with 11 false-negative results (sensitivity: 89%). In patients with CP, only seven of 13 malignancies (all solid adenocarcinomas) were identified using FNA (sensitivity: 54%). Overall, malignancy was identified in 116 patients, 32 of whom (27%) had lesions other than primary solid adenocarcinomas. Management was altered in 25 of these patients, which changed the surgical approach in 21%. EUS-FNA influenced the therapeutic approach in 44% of the total patient group. CONCLUSIONS: EUS-FNA was especially useful in patients with a focal pancreatic lesion with normal parenchyma. Its sensitivity in patients with CP was unacceptably low, and resection of the tumor using standard surgical techniques was still usually required to confirm the correct diagnosis. Diagnostic EUS-FNA influenced clinical management in nearly half of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dumonceau, J.-M., Deprez, P., Jenssen, C., Iglesias-Garcia, J., Larghi, A., Vanbiervliet, G., Aithal, G., Arcidiacono, P., Bastos, P., Carrara, S., et al. (2017) · Endoscopy · doi:10.1055/s-0043-109021 · Cited by 351
Hébert‐Magee, S., Bae, S., Varadarajulu, S., Ramesh, J., Frost, A. R., Eloubeidi, M. A., & Eltoum, I. A. (2013) · Cytopathology · doi:10.1111/cyt.12071 · Cited by 321
Săftoiu, A., Vilmann, P., Gorunescu, F., Gheonea, D. I., Gorunescu, M., Ciurea, T., Popescu, G. L., Iordache, A., Hassan, H., & Iordache, S. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.04.031 · Cited by 260
Săftoiu, A., Vilmann, P., Dietrich, C. F., Iglesias-Garcia, J., Hocke, M., Seicean, A., Ignee, A., Hassan, H., Streba, C. T., Ioncică, A. M., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.11.040 · Cited by 150
Zhu, M., Xu, C., Yu, J., Wu, Y., Li, C., Zhang, M., Jin, Z., & Li, Z. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063820 · Cited by 114
Metadata
- Authors
- Fritscher‐Ravens, A., Brand, L., Knöfel, W. T., Bobrowski, C., Topalidis, T., Thonke, F., deWeerth, A., & Soehendra, N.
- Venue
- The American Journal of Gastroenterology
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2002-11-01
- Volume
- 97
- Issue
- 11
- Pages
- 2768-2775
- ISSN
- 0002-9270 (ISSN-L)
- OpenAlex
- W1974504452
- Cited by
- 287
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of endoscopic ultrasound-guided fine needle aspiration for focal pancreatic lesions in patients with normal parenchyma and chronic pancreatitis. https://app.cochat.ai/papers/10.1016/s0002-9270(02)05437-0
- The paper
- Fritscher‐Ravens, A., Brand, L., Knöfel, W. T., Bobrowski, C., Topalidis, T., Thonke, F., deWeerth, A., & Soehendra, N. (2002). Comparison of endoscopic ultrasound-guided fine needle aspiration for focal pancreatic lesions in patients with normal parenchyma and chronic pancreatitis. The American Journal of Gastroenterology. https://doi.org/10.1016/s0002-9270(02)05437-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.