CoChat

Wide angle colonoscopy with a prototype instrument: impact on miss rates and efficiency as determined by back-to-back colonoscopies

Douglas K. Rex, Vidyasree Chadalawada, Debra J. Helper · 2003 · The American Journal of Gastroenterology
Cited by 110

The DOI matches its OpenAlex record.

Abstract

OBJECTIVE: Polyps are missed during conventional colonoscopy, even with meticulous technique. The aim of this study was to investigate whether a prototype wide angle colonoscope is associated with a reduced miss rate for polyps. METHODS: Two studies were performed. In study 1, a total of 50 patients underwent back-to-back, same-day colonoscopy by a single examiner with the prototype wide angle colonoscope and with a standard colonoscope, with the order of scopes randomized. In study 1, an attempt was made to keep examination time with the two colonoscopes equal. In study 2, a total of 20 patients were examined, 10 by the same colonoscopist who performed study 1 and 10 by a second colonoscopist. In study 2, examiners tried to perform the examinations as quickly as accuracy would allow. RESULTS: In study 1, the miss rate for all polyps was lower with the wide angle colonoscope (20% vs 31%; p = 0.046), although the mean examination time with the wide angle instrument was shorter (6.75 min vs 7.64 min; p = 0.0005). There was no significant difference in detection of adenomas. Polyps, including adenomas, were missed in the peripheral endoscopic field more frequently with the standard colonoscope. In study 2, wide angle colonoscopy was associated with reductions in examination time of 25% and 30% for the two examiners, respectively. Miss rates were the same for one colonoscopist but were higher for the other colonoscopist when the wide angle instrument was used. CONCLUSION: A prototype wide angle colonoscope did not eliminate polyp miss rates. Wide angle colonoscopy has the potential to reduce examination time and improve visualization of the periphery of the endoscopic field of view, but improvements in resolution are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1016/s0002-9270(03)00625-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 110

Metadata

Authors
Rex, D. K., Chadalawada, V., & Helper, D. J.
Venue
The American Journal of Gastroenterology
Publisher
Lippincott Williams & Wilkins
Published
2003-09-01
Volume
98
Issue
9
Pages
2000-2005
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2071919534
Cited by
110
References
0
FWCI
1.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wide angle colonoscopy with a prototype instrument: impact on miss rates and efficiency as determined by back-to-back colonoscopies. https://app.cochat.ai/papers/10.1016/s0002-9270(03)00625-7
The paper
Rex, D. K., Chadalawada, V., & Helper, D. J. (2003). Wide angle colonoscopy with a prototype instrument: impact on miss rates and efficiency as determined by back-to-back colonoscopies. The American Journal of Gastroenterology. https://doi.org/10.1016/s0002-9270(03)00625-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.