The DOI matches its Crossref record.
Evaluation of optineurin sequence variations in 1,048 patients with open-angle glaucoma
Open accessAbstract
PURPOSE To investigate the association of sequence variations in the optineurin (OPTN) gene in patients with open-angle glaucoma. DESIGN Prospective case control study. METHODS The OPTN gene was screened for sequence variations using a combination of single-strand conformational polymorphism analysis and automated DNA sequencing. A total of 1,299 subjects (1048 glaucoma patients and 251 controls) were screened for variations in the four portions of the gene that had been previously associated with glaucoma. A subset of these subjects (376 patients and 176 controls) was screened for variations in the entire coding sequence. Twenty-four percent of the patients and 35% of the controls were Japanese, whereas the remainder were predominantly Caucasian. Allele frequencies were compared with the Fisher exact test. RESULTS The OPTN sequence variations were not significantly associated with any form of high-tension open-angle glaucoma. One proband with familial normal-tension glaucoma was found to harbor the previously reported Glu50Lys variation. Another previously reported change, Met98Lys, was associated with normal-tension glaucoma in Japanese but not in Caucasian patients. CONCLUSIONS This study provides some additional evidence for the association of the Glu50Lys OPTN sequence variation with familial normal tension glaucoma. However, because familial normal-tension glaucoma is so rare, this change seems to be responsible for less than 0.1% of all open-angle glaucoma. The Arg545Gln variation is likely to be a nondisease-causing polymorphism. The Met98Lys change may be associated with a fraction of normal-tension glaucoma in patients of Japanese ethnicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mitochondrial Abnormalities in Patients with Primary Open-Angle Glaucoma
Abu-Amero, K. K., Morales, J., & Bosley, T. M. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1639 · Cited by 337
Zhu, G., Wu, C.-J., Zhao, Y., & Ashwell, J. D. (2007) · Current Biology · doi:10.1016/j.cub.2007.07.041 · Cited by 282
Ito, Y. A., & Di Polo, A. (2017) · Mitochondrion · doi:10.1016/j.mito.2017.08.014 · Cited by 142
Chi, Z.-L., Akahori, M., Obazawa, M., Minami, M., Noda, T., Nakaya, N., Tomarev, S., Kawase, K., Yamamoto, T., Noda, S., et al. (2010) · Human Molecular Genetics · doi:10.1093/hmg/ddq146 · Cited by 151
Self-citation
Metadata
- Authors
- Alward, W. L. M., Kwon, Y. H., Kawase, K., Craig, J. E., Hayreh, S. S., Johnson, A. T., Khanna, C. L., Yamamoto, T., Mackey, D. A., Roos, B. R., Affatigato, L. M., Sheffield, V. C., & Stone, E. M.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 136
- Issue
- 5
- Pages
- 904-910
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W1995887719
- Cited by
- 183
- References
- 0
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of optineurin sequence variations in 1,048 patients with open-angle glaucoma. https://app.cochat.ai/papers/10.1016/s0002-9394(03)00577-4
- The paper
- Alward, W. L. M., Kwon, Y. H., Kawase, K., Craig, J. E., Hayreh, S. S., Johnson, A. T., Khanna, C. L., Yamamoto, T., Mackey, D. A., Roos, B. R., Affatigato, L. M., Sheffield, V. C., & Stone, E. M. (2003). Evaluation of optineurin sequence variations in 1,048 patients with open-angle glaucoma. American Journal of Ophthalmology. https://doi.org/10.1016/s0002-9394(03)00577-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.