Excimer Laser Surgery of the Cornea
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Photorefractive keratectomy: A technique for laser refractive surgery
Munnerlyn, C. R., Koons, S. J., & Marshall, J. (1988) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(88)80063-4 · Cited by 763
Wound Healing After Excimer Laser Keratomileusis (Photorefractive Keratectomy) in Monkeys
Fantes, F. E. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070070051034 · Cited by 747
Photophysical processes in recent medical laser developments: A review
Boulnois, J.-L. (1986) · Lasers in Medical Science · doi:10.1007/bf02030737 · Cited by 661
Ablation of Polymers and Biological Tissue by Ultraviolet Lasers
Srinivasan, R. (1986) · Science · doi:10.1126/science.3764428 · Cited by 562
Self-citationLaser in situ keratomileusis: Literature review of a developing technique
Farah, S. G., Azar, D. T., Gurdal, C., & Wong, J. (1998) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(98)80056-4 · Cited by 281
An Ultrastructural Study of Corneal Incisions Induced by an Excimer Laser at 193 nm
Marshall, J., Trokel, S., Rothery, S., & Schubert, H. (1985) · Ophthalmology · doi:10.1016/s0161-6420(85)33961-1 · Cited by 277
Self-citationLaser ablation of organic polymers: Microscopic models for photochemical and thermal processes
Garrison, B. J., & Srinivasan, R. (1985) · Journal of Applied Physics · doi:10.1063/1.335230 · Cited by 233
Self-citationPhotorefractive Keratectomy With an Argon Fluoride Excimer Laser: A Clinical Study
Gartry, D. S., Muir, M. G. K., & Marshall, J. (1991) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19911101-06 · Cited by 231
Cell delivery in regenerative medicine: The cell sheet engineering approach
Yang, J., Yamato, M., Nishida, K., Ohki, T., Kanzaki, M., Sekine, H., Shimizu, T., & Okano, T. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.06.022 · Cited by 215
Excimer Laser Ablation Rate and Corneal Hydration
Dougherty, P. J., Wellish, K. L., & Maloney, R. K. (1994) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)72896-x · Cited by 201
Corneal Wound Healing After 193-nm Excimer Laser Keratectomy
Wu, W. C. S. (1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080100106053 · Cited by 163
Human Excimer Laser Lamellar Keratectomy
Taylor, D. M., L'Esperance, F. A., Del Pero, R. A., Roberts, A. D., Gigstad, J. E., Klintworth, G., Martin, C. A., & Warner, J. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32836-3 · Cited by 162
Mrochen, M., Schelling, U., Wuellner, C., & Donitzky, C. (2009) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2008.10.053 · Cited by 25
Comparison of different excimer laser ablation frequencies (50, 200, and 500 Hz)
Winkler von Mohrenfels, C., Khoramnia, R., & Lohmann, C.-P. (2009) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-009-1102-x · Cited by 19
“In the first studies, surgeons performed surgery with small ablation zones (4– 5 mm) [1, 2].”
Background
Metadata
- Authors
- Trokel, S. L., Srinivasan, R., & Braren, B.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 1983-12
- Volume
- 96
- Issue
- 6
- Pages
- 710-715
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2084460919
- Cited by
- 990
- References
- 0
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.