Analysis of the Composite Response of Shear Wave Resonators to the Attachment of Mammalian Cells
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Pierschbacher, M. D., & Ruoslahti, E. (1984) · Nature · doi:10.1038/309030a0 · Cited by 3,658
Buttry, D. A., & Ward, M. D. (1992) · Chemical Reviews · doi:10.1021/cr00014a006 · Cited by 1,375
Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins
Muramatsu, H., Dicks, J. M., Tamiya, E., & Karube, I. (1987) · Analytical Chemistry · doi:10.1021/ac00150a007 · Cited by 350 · cited 2×
“It has been shown repeatedly for various model systems that the QCM is sensitive enough to detect the specific adsorption of small amounts of protein to the resonator surface, for instance, binding of antibodies to immobilized antigens (Rickert et al., 1997; Muramatsu et al., 1987) or binding of bacterial toxins to th…”
BackgroundImpedance analysis of MDCK cells measured by electric cell-substrate impedance sensing
Lo, C. M., Keese, C. R., & Giaever, I. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80153-0 · Cited by 272 · cited 1×
“Epithelial cells, however, tend to attach very firmly to artificial surfaces with small average cell-substrate separation distances (Lo et al., 1995).”
BackgroundThe Piezoelectric Quartz Crystal Mass and Dissipation Sensor: A Means of Studying Cell Adhesion
Fredriksson, C., Kihlman, S., Rodahl, M., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la971005l · Cited by 242 · cited 2×
“Our findings were later independently confirmed by Fredriksson et al. (1998), who used simultaneous resonance frequency and dissipation factor measurements.”
ResultResolving Heterogeneity on the Single Molecular Level with the Photon-Counting Histogram
Müller, J. D., Chen, Y., & Gratton, E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76610-0 · Cited by 184
Real‐Time Measurement of Anchorage‐Dependent Cell Adhesion Using a Quartz Crystal Microbalance
Gryte, D. M., Ward, M. D., & Hu, W. (1993) · Biotechnology Progress · doi:10.1021/bp00019a016 · Cited by 134
Viscoelastic characterization of electroactive polymer films at the electrode/solution interface
Bandey, H. L., Hillman, A. R., Brown, M. J., & Martin, S. J. (1997) · Faraday Discussions · doi:10.1039/a704278g · Cited by 133 · cited 4×
“…the deposition of thin metal films from vapor phase (Sauerbrey, 1959), growth rate control during electrodeposition of polymer films from solution (Bandey et al., 1997), and even the detection of molecular recognition events when the quartz surface is made specifically functional with receptors…”
BackgroundResultInfluentialWegener, J., Zink, S., Rosen, P., & Galla, H. (1999) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240050864 · Cited by 119 · cited 1×
“As reported earlier (Wegener et al., 1999), we also learned from cross-sectional images using confocal laser scanning mi- croscopy that these cells show a very large spacing of more FIGURE 8 Increase in the motional resistance as a function of medium osmolarity for MDCK-I (E), MDCK-II (F), and 3T3…”
BackgroundSelf-citationSpecific Adhesion of Vesicles Monitored by Scanning Force Microscopy and Quartz Crystal Microbalance
(2000) · doi:10.1016/s0006-3495(00)76611-2 · Cited by 113 · cited 1×
“It is interesting to correlate these results with combined QCM/ scanning force microscopy (SFM) studies that were directed toward vesicle adsorption (Pignataro et al., 2000).”
ResultQuartz crystal microbalances for quantitative biosensing and characterizing protein multilayers
Rickert, J., Brecht, A., & Göpel, W. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(96)00077-2 · Cited by 106
Tight Junction Permeability to Ions and Water
Reuss, L. (2001) · CRC Press eBooks · doi:10.1201/9781420038538.ch4 · Cited by 78
Kramer, R. H., Fuh, G.-M., Bensch, K. G., & Karasek, M. A. (1985) · Journal of Cellular Physiology · doi:10.1002/jcp.1041230102 · Cited by 69 · cited 2×
“It requires killing of the cells by hyposmotic lysis and removal of the remaining cell debris with a detergent-containing buffer (Kramer et al., 1985).”
BackgroundMethodGath, U., Hakvoort, A., Wegener, J., Decker, S. R. R., & Galla, H. (1997) · PubMed · Cited by 68
Self-citationThe role of non-lamellar lipid structures in the formation of tight junctions
Wegener, J., & Galla, H. (1996) · Chemistry and Physics of Lipids · doi:10.1016/0009-3084(96)02585-6 · Cited by 40 · cited 1×
“These so-called tight junctions (Wegener and Galla, 1996) occlude the intercellular diffusion pathway and thereby enable epithelial cell layers to act as a selective barrier between two different fluid compartments.”
BackgroundSelf-citationZink, S., Rösen, P., Sackmann, B., & Lemoine, H. (1993) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/0167-4889(93)90206-5 · Cited by 36
Organic osmolytes increase cytoplasmic viscosity in kidney cells
Periasamy, N., Kao, H. P., Fushimi, K., & Verkman, A. S. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.263.4.c901 · Cited by 31 · cited 1×
“More recent studies by Periasamy et al. (1992) have shown that the cytoplasmic viscosity of adherent MDCK cells increased by 50% when the cells were kept in hyperosmotic culture medium (1200 mOsm/kg H2O).”
BackgroundParak, W. J., Domke, J., George, M., Kardinal, A., Radmacher, M., Gaub, H. E., de Roos, A. D. G., Theuvenet, A. P. R., Wiegand, G., Sackmann, E., et al. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77325-x · Cited by 28
Cited by
Marx, K. A. (2003) · Biomacromolecules · doi:10.1021/bm020116i · Cited by 1,143
A Review of Cell Adhesion Studies for Biomedical and Biological Applications
Khalili, A., & Ahmad, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160818149 · Cited by 951
Piezoelectric Mass-Sensing Devices as Biosensors—An Alternative to Optical Biosensors?
Janshoff, A., Galla, H.-J., & Steinem, C. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001117)39:22<4004::aid-anie4004>3.0.co;2-2 · Cited by 712
Self-citationLabel-free screening of bio-molecular interactions
Cooper, M. A. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2111-y · Cited by 460
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Metadata
- Authors
- Wegener, J., Seebach, J., Janshoff, A., & Galla, H.-J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2000-06
- Volume
- 78
- Issue
- 6
- Pages
- 2821-2833
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2006254525
- Cited by
- 160
- References
- 21
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.