The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Fiber Orientation and Ejection Fraction in the Human Left Ventricle
Open accessAbstract
Fiber orientation and ventricular geometry are incorporated in a mathematical model for ejection fraction of the human left ventricle. The inadequacy of circularly oriented or "constrictor" fibers to explain high ejection fractions of cylindrical, spherical, or ellipsoidal reference ventricles is demonstrated. A class of "helical" fibers is then introduced from which ejection fractions predicted by physiologic amounts of fiber shortening on cylindrical and ellipsoidal reference ventricles are shown to be consistent with those calculated from biplane angio-cardiographic films.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Overall, these results were consistent with the projections of previous analytical and computational models (3, 25, 36) in that they showed more-homogeneous deformations for HA ventricles.”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It has been predicted that EFs should scale as 1 – k2 for CA ventricles (eq. S5) and 1 - k2 q H(α) for HA ventricles (eq. S15) (Fig. 2D) (3), with k being the strain along the fiber axis, q being the apical shortening, and H(α) being the radial shortening based on the fiber’s helical angle (eqs. S5 to S15).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It has been hypothesized that HA ventricles would display increased apical shortening (3, 36) and reduced basal displacement (9, 36), owing to differences in myofiber lengths.”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Sallin’s model predicted an EF increase of 54 to 64% for HA ventricles, which was consistent with our experimental observations (within the standard error of the mean; Fig. 3E).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“showing that the biomechanics of these single-layer ventricle models is consistent with theoretical predictions from the past 50 years (3, 4, 25).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
The cited source says what the claim attributes to it.
In the citing paper
“Over the past half-century, it has been argued that this helical arrangement represents a fundamental structural design critical to achieving large ejection fractions (EFs) (1, 3–6).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Scaling Sallin’s model to physiological relevant strains (~15 to 20%) (3), we noted that single-angle ventricles could achieve EFs of only up to ~43% (α = 30°) (see supplementary materials for details).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [3]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
Streeter, D. D., Spotnitz, H. M., PATEL, D. P., Ross, J., & Sonnenblick, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,457
Force-velocity relations in mammalian heart muscle
Sonnenblick, E. H. (1962) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1962.202.5.931 · Cited by 711
Usefulness and limitations of radiographic methods for determining left ventricular volume
Dodge, H. T., Sandler, H., Baxley, W. A., & Hawley, R. R. (1966) · The American Journal of Cardiology · doi:10.1016/0002-9149(66)90191-3 · Cited by 613
Quantitative Angiocardiography: I. The Normal Left Ventricle in Man
Kennedy, J. W., Baxley, W. A., Figley, M., Dodge, H. T., & Blackmon, J. R. (1966) · Circulation · doi:10.1161/01.cir.34.2.272 · Cited by 296
Series elastic and contractile elements in heart muscle: changes in muscle length
Sonnenblick, E. H. (1964) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1964.207.6.1330 · Cited by 199
The Architecture of the Heart in Systole and Diastole
Ross, J., Sonnenblick, E. H., Covell, J. W., Kaiser, G. A., & Spiro, D. (1967) · Circulation Research · doi:10.1161/01.res.21.4.409 · Cited by 118
Instantaneous Force-Velocity-Length Determinants in the Contraction of Heart Muscle
Sonnenblick, E. H. (1965) · Circulation Research · doi:10.1161/01.res.16.5.441 · Cited by 104
Onset of contractility in cardiac muscle
Brady, A. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007931 · Cited by 100
Research works printed but not linked: 2
- [6]6. STREEIER, JR., D. D., H. M. SpoTmTz, D. J. PATEL, J. Ross, JR., and E. H. SONNENBLICK. 1969. Circ. Res. 24(3):339.
- [7]7. DODGE, H. T., H. SANDLER, W. A. BAXLEY, and R. R. HAWLEY. 1966. Amer. J. Cardiol. 18(1):10.
Cited by
Sorted by citations
Items 201–240 of 240
Ventricular Remodeling in Heart Failure
Aquila, I., & Shah, A. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.10903-2 · Cited by 1
Sefton, M. V., & Simmons, C. A. (2022) · Science · doi:10.1126/science.add0829 · Cited by 1
Optimized Biomechanical Design of a Pulsatile Fontan Conduit for Congenital Heart PalliationPreprint
Emuna, N., Marsden, A. L., & Humphrey, J. D. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.06.19.599796 · Cited by 1
Altered Left Ventricular Geometry in Ischemic Cardiomyopathy
Parachuri, V. R., & Adhyapak, S. M. (2012) · Springer eBooks · doi:10.1007/978-1-4471-2861-8_3
Physiological adaptations to chronic hypoxemia in eisenmenger syndrome
Bowater, S. E. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham)
The maximal fluid flow rate and the “Gold” angle of a swirling flow in a tube
Chefranov, S. G. (2009) · Doklady Physics · doi:10.1134/s1028335809050097
Magubane, M. M., Woodiwiss, A. J., Norton, G. R., & Michel, F. S. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.03.304
Cho, S.-M., Kim, H.-S., HALKAR, R. K., Chung, S.-K., Song, K.-S., Lee, K., Lee, B. Y., Park, Y. G., & Park, J. Y. (2009) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328330c791
Correia, R. J. (2011) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg)
Ventricular Rotation and the Rotation Axis A New Concept in Cardiac Function
Gustafsson, U. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Toward empirical evaluation of left ventricle function: a novel mathematical mapping
Dabiri, J. O., & Gharib, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106382
Electrical Propagation in the Mechanisms of Torsion and Suction in a Three-phase Heart
Trainini, J. C., Elencwajg, B., López-Cabanillas, N., Herreros, J. M., Lago, N., & Lowenstein, J. A. (2015) · Revista Argentina de Cardiología · doi:10.7775/rac.v83.i5.6732
The results of surgical left ventricular restoration
Deja, M. A., Janusiewicz, P., Biernat, J., Malinowski, M., Golba, K. S., Domaradzki, W., Bachowski, R., & Ceglarek, W. (2008)
Cardiovascular Magnetic Resonance Imaging and MR-Conditional Cardiac Devices
Eggen, M. D., & Swingen, C. (2015) · Springer eBooks · doi:10.1007/978-3-319-19464-6_24
Krüger, W. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-54973-6_4
Heart Mechanics: From Implanted Markers to Magnetic Resonance Imaging Tagging
Ibrahim, E.-S. H. (2017) · doi:10.1201/9781315119083-17
Left Ventricular Reconstruction and Conventional Surgery for Cardiac Failure
Beyersdorf, F., & Siepe, M. (2017) · Springer eBooks · doi:10.1007/978-3-662-52672-9_23
OBSOLETE: Ventricular Remodeling in Heart Failure
Shah, A. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.10903-1
Fredriksson, A. G. (2017) · Linköping University medical dissertations · doi:10.3384/diss.diva-143417
Modifying and Measuring the Stiffness of a Regenerative Cardiac Scaffold In Vitro
Filipe, D. (2010) · Digital WPI
Ventricular mural architecture. Response
Antúnez‐Montes, O. Y., Olavarría, A. S., & Kočica, M. J. (2019) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2019.08.008
Thyroid Hormone and Cardiac Repair
Pantos, C. I. (2020) · Springer eBooks · doi:10.1007/978-3-030-36871-5_12
Földeák, D., Kalapos, A., Domsik, P., Sinkó, M., Szeleczki, N., Bagdi, E., Krenács, L., Forster, T., Borbényi, Z., & Nemes, A. (2017) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2017.02.013
López‐Candales, A. (2014) · Springer eBooks · doi:10.1007/978-1-4471-2398-9_11
Валерьевич, Ч. П., Хамидбиевич, М. М., Александрович, А. И., Марсовна, Б. Н., Kambarov, S. Y., Анварович, С. М., Владимирович, Д. А., Timerbaev, A. V., & Харитонова, Н. И. (2022) · Russian Sklifosovsky Journal Emergency Medical Care · doi:10.23934/2223-9022-2022-11-1-50-58
Arvidsson, P. M., & Kovács, S. J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91391-1.00014-5
Evaluation of Diastolic Function by Tissue Doppler, Strain, and Torsion Analysis
Makkiya, M., & Garcia, M. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-64067-1.00010-3
Ibrahim, E. H., Sigfridsson, A., & Kvitting, J. E. (2017) · CRC Press eBooks · doi:10.1201/9781315119083-10
Cardiovascular Magnetic Resonance Imaging and MR-Conditional Cardiac Devices
Reifart, J., Eggen, M. D., & Swingen, C. (2024) · Springer eBooks · doi:10.1007/978-3-031-72581-4_25
邱, 福. (2025) · Advances in Clinical Medicine · doi:10.12677/acm.2025.1561790
Evolution and Predictors of Right Ventricular Failure in Fontan Patients: A Case-Control Study
Kim, H. S., Abarbanell, G. L., Simpson, K. E., Abarbanell, A. M., Eghtesady, P., Levy, P. T., & Singh, G. K. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14134602
Turner, D. G. P., de Lange, W. J., Leonov, V., Medvedev, R. Y., Port, J. M., Bamlett, J. T., Lang, D., Jang, H. J., Zhang, J., Schmuck, E. G., et al. (2025) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00216.2025
Stroke volume analog on a chip – in vitro hydrodynamic model of cardiac pumping efficiency
Zimmerman, J. F., MacQueen, L. A., Henze, D. E., Drennan, D. J., Kim, S. L., Ardoña, H. A. M., Choi, S., Jin, Q., & Parker, K. K. (2026) · Lab on a Chip · doi:10.1039/d5lc00547g
Akhmimi, A., Lip, G. Y. H., Sprung, V. S., Oxborough, D., & Shantsila, A. (2026) · Echocardiography · doi:10.1111/echo.70515 · Cited by 1
Normal Left Ventricular Dynamics: Contraction and Relaxation Patterns
Parachuri, V. R., & Adhyapak, S. M. (2012) · Springer eBooks · doi:10.1007/978-1-4471-2861-8_2
Impact of asymptomatic hypertension on left ventricular functions.
Bhatt, J. V. (2003) · PubMed
Metadata
- Authors
- Sallin, E. A.
- Affiliations
- University of Alabama (US)
- Corresponding author
- Sallin, Edward A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1969-07
- Volume
- 9
- Issue
- 7
- Pages
- 954-964
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1367490
- OpenAlex
- W1994976809
- Cited by
- 240
- References
- 8
- Citations by year
- 2026: 5 · 2025: 9 · 2024: 9 · 2023: 9 · 2022: 12 · 2021: 5 · 2020: 10 · 2019: 7 · 2018: 12 · 2017: 18 · 2016: 10 · 2015: 8 · 2014: 12 · 2013: 5 · 2012: 7
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- left ventricle, ejection fraction, myocardial fiber orientation, helical fibers, ventricular geometry, fiber shortening
- MeSH terms
- Heart, Models, Biological, Ventricular Function
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review