The DOI matches its Crossref record.
Model Studies of the Magnetocardiogram
Open accessAbstract
A general expression is developed for the quasi-static magnetic field outside an inhomogeneous nonmagnetic volume conductor containing internal electromotive forces. Multipole expansions for both the electric and magnetic fields are derived. It is shown that the external magnetic field vanishes under conditions of axial symmetry. The magnetic field for a dipole current source in a sphere is derived, and the effect of an eccentric spherical inhomogeneity is analyzed. Finally the magnetic dipole moment is calculated for a current dipole in a conducting prolate spheroid.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a foundational research from the general theory of bioelectromagnetism describes the amount of potential additional information provided by MCG (1–7)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [3]
Citations
Cited by
Sorted by citations
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Näätänen, R., & Picton, T. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00311.x · Cited by 3,321
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem.
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,945
“Analternativederivation of formulae for U and B outside G was performed by Grynszpan and Geselowitz (1973) and Ilmoniemi et al (1985).”
MethodPantev, C., Hoke, M., Lehnertz, K., Lütkenhöner, B., Anogianakis, G., & Wittkowski, W. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90211-8 · Cited by 401
Hari, R., Kai, K.-L., Katila, T., Tuomisto, T., & Varpula, T. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90041-4 · Cited by 369
Somatosensory evoked cerebral magnetic fields from SI and SII in man.
Hari, R., Reinikainen, K., Kaukoranta, E., Hämäläinen, M., Ilmoniemi, R., Penttinen, A., Salminen, J., & Teszner, D. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90126-3 · Cited by 366
Tonotopic organization of the human auditory cortex.
Romani, G., Williamson, S. J., & Kaufman, L. (1982) · Science · doi:10.1126/science.7079770 · Cited by 341
The hippocampal formation as a source of the slow endogenous potentials.
Okada, Y., Kaufman, L., & Williamson, S. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90130-x · Cited by 327
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Comparison of the magnetoencephalogram and electroencephalogram.
Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 292
Conductivities of Three-Layer Live Human Skull
Akhtari, M., Bryant, H., Mamelak, A., Flynn, E., Heller, L., Shih, J. J., Mandelkem, M., Matlachov, A., Ranken, D., Best, E., et al. (2004) · Brain Topography · doi:10.1023/a:1014590923185 · Cited by 255
“Copyright 2002 Human Sciences Press, Inc. Model (BEM), and Finite Element Model (FEM) are among the most widely used (Fuchs et al. 1998; Buchner et al. 1997; Yan et al. 1991; Hämäläinen and Sarvas 1989; Sarvas 1987; Stock 1986; Meijs et al. 1985; Grynszpan and Gezelowitz 1973; Barnard et al 1967).”
MethodMagnetic Fields of a Dipole in Special Volume Conductor Shapes
Cuffin, B., & Cohen, D. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326145 · Cited by 251
Spatiotemporal Activity of a Cortical Network for Processing Visual Motion Revealed by MEG and fMRI
Ahlfors, S. P., Simpson, G. V., Dale, A. M., Belliveau, J. W., Liu, A. K., Korvenoja, A., Virtanen, J. P., Huotilainen, M., Tootell, R. B. H., Aronen, H. J., et al. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2545 · Cited by 234
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Barkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“The ECD is not a physical point, but it represents the activity of a small collection of synchronously firing neurons (Grynszpan and Geselowitz, 1973).”
BackgroundThe advantage of combining MEG and EEG: Comparison to fMRI in focally stimulated visual cortex
Sharon, D., Hämäläinen, M., Tootell, R. B. H., Halgren, E., & Belliveau, J. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.03.066 · Cited by 212
“, 1962; Geisler and Gerstein, 1961), whereas it does not affect the magnetic fields (Grynszpan and Geselowitz, 1973); this confers a localization advantage for MEG, for those sources that it is able to detect (Cuffin and Cohen, 1979).”
BackgroundNeuromagnetic evidence of pre- and post-central cortical sources of somatosensory evoked responses.
Kawamura, T., Nakasato, N., Seki, K., Kanno, A., Fujita, S., Fujiwara, S., & Yoshimoto, T. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0168-5597(95)00217-0 · Cited by 177
The influence of model parameters on EEG/MEG single dipole source estimation
Stok, C. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326090 · Cited by 172
Effects of head shape on EEGs and MEGs
Cuffin, B. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 170
Analysis of Multimodal Neuroimaging Data
Bießmann, F., Plis, S., Meinecke, F. C., Eichele, T., & Müller, K. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2170675 · Cited by 163
“The magnetic fields measured with MEG are not affected by volume conduction and can resolve finer structures than EEG [55], [108].”
BackgroundSupek, S., & Aine, C. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237672 · Cited by 153
Spatio-temporal analysis of cortical activity evoked by gustatory stimulation in humans.
Kobayakawa, T., Ogawa, H., Kaneda, H., Ayabe-Kanamura, S., Endo, H., & Saito, S. (1999) · Chemical Sensors · doi:10.1093/chemse/24.2.201 · Cited by 146
“Estimation of equivalent dipoles (ECDs) were carried out to minimize the estimation error, based onthe Grynszpan–Geselowitz equation (Grynszpan and Geselowitz, 1973; see Kobayakawa et al., 1996b).”
MethodCancellation of EEG and MEG Signals Generated by Extended and Distributed Sources
Ahlfors, S., Han, J., Lin, F., Witzel, T., Belliveau, J., Hämäläinen, M., & Halgren, E. (2009) · Human Brain Mapping · doi:10.1002/hbm.20851 · Cited by 142
“Since MEG is insensitive to radially oriented sources [Grynszpan and Geselowitz, 1973], strong cancellation is expected for MEG, whereas the radial sources will still generate prominent EEG signals [Eulitz et al., 1997; Freeman et al., 2009].”
BackgroundPantev, C., Hoke, M., Lehnertz, K., Lütkenhöner, B., Fahrendorf, G., & Stöber, U. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90171-f · Cited by 131
SQUID sensor array configurations for magnetoencephalography applications
Vrba, J., & Robinson, S. E. (2002) · Superconductor Science and Technology · doi:10.1088/0953-2048/15/9/201 · Cited by 126
Neuromagnetic studies of somatosensory system: principles and examples.
Hari, R., & Kaukoranta, E. (1985) · Progress in neurobiology · doi:10.1016/0301-0082(85)90007-3 · Cited by 126
Effects of local variations in skull and scalp thickness on EEG's and MEG's
Cuffin, B. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204770 · Cited by 123
Ferguson, A. S., Zhang, X., & Stroink, G. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293220 · Cited by 121
Magnetoencephalography and epilepsy research.
Rose, D., Smith, P., & Sato, S. (1987) · Science · doi:10.1126/science.3310234 · Cited by 121
Nakasato, N., Fujita, S., Seki, K., Kawamura, T., Matani, A., Tamura, I., Fujiwara, S., & Yoshimoto, T. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)00280-x · Cited by 117
A Bidomain Model Based BEM-FEM Coupling Formulation for Anisotropic Cardiac Tissue
Fischer, G., Tilg, B., Modre, R., Huiskamp, G., Fetzer, J., Rucker, W., & Wach, P. (2004) · Annals of Biomedical Engineering · doi:10.1114/1.1318927 · Cited by 117
The unique determination of neuronal currents in the brain via magnetoencephalography
Fokas, A., Kurylev, Y., & Marinakis, V. (2004) · Inverse Problems · doi:10.1088/0266-5611/20/4/005 · Cited by 113
“4) reduces to [6]–[8] B = μ0∇U, U(x) = 1 4π ∫”
CHAPTER 9 – Magnetoencephalography and Magnetic Source Imaging
Lewine, J., & Orrison, W. (1995) · Elsevier eBooks · doi:10.1016/b978-0-8151-6509-5.50013-8 · Cited by 112
Nummenmaa, A. R., Stenroos, M., Ilmoniemi, R. J., Okada, Y. C., Hämäläinen, M., & Raij, T. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.04.019 · Cited by 106
“N IH -PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript that radial primary currents in a spherically symmetric volume conductor do not produce external magnetic fields (Baule and McFee, 1965, Grynszpan and Geselowitz, 1973).”
BackgroundOn MEG forward modelling using multipolar expansions
Jerbi, K., Mosher, J. C., Baillet, S., & Leahy, R. M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/4/301 · Cited by 103
“Although this is not the only possible method, it is straightforward and has been widely used in MCG source localization (e.g. Katila 1983, Nenonen et al 1991).”
BackgroundMethodInfluentialBROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Medical imaging: state of the art and future development
Louis, A. (1992) · doi:10.1088/0266-5611/8/5/003 · Cited by 98
A Comparison of Moving Dipole Inverse Solutions Using EEG's and MEG's
Cuffin, B. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325622 · Cited by 96
On the relation between somatic evoked potentials and fields.
Kaufman, L., Okada, Y. C., Brenner, D., & Williamson, S. J. (1981) · International Journal of Neuroscience · doi:10.3109/00207458108985860 · Cited by 93
Experimental analysis of distortion of magnetoencephalography signals by the skull.
Okada, Y., Lähteenmäki, A., & Xu, C.-B. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00099-6 · Cited by 92
Bowyer, S. M., Tepley, N., Papuashvili, N., Kato, S., Barkley, G., Welch, K., & Okada, Y. (1999) · Brain Research · doi:10.1016/s0006-8993(99)01893-4 · Cited by 87
Barkley, G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.011 · Cited by 81
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Gustatory evoked cortical activity in humans studied by simultaneous EEG and MEG recording.
Mizoguchi, C., Kobayakawa, T., Saito, S., & Ogawa, H. (2002) · Chemical Sensors · doi:10.1093/chemse/27.7.629 · Cited by 78
“However, MEG measurement is not capable of recording cortical activation of gyri where the electric current generated is oriented vertically to the brain surface (Gryzpan and Geselowitz, 1973).”
BackgroundBabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research.
Okada, Y., Hämäläinen, M., Pratt, K., Mascarenas, A., Miller, P., Han, M.-L., Robles, J., Cavallini, A., Power, B., Sieng, K., et al. (2016) · Review of Scientific Instruments · doi:10.1063/1.4962020 · Cited by 76
The EEG and MEG, Using a Model of Eccentric Spheres to Describe the Head
Meijs, J. W. H., & Peters, M. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325929 · Cited by 74
“Because Bn is not affected by the volume currents when using the concentric spheres model [2], this field distribution reflects the source only and is therefore often called the "source term.”
BackgroundOkada, Y., Lähteenmäki, A., & Xu, C.-B. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00111-4 · Cited by 70
Review of electromagnetic source investigations of the fetal heart.
Lewis, M. (2003) · Medical Engineering and Physics · doi:10.1016/s1350-4533(03)00121-8 · Cited by 68
“The most common approach to the solution of this problem is to approximate the current distribution (assumed to be localised according to realistic anatomical and physiological constraints) using a finite number of current dipoles of differing magnitudes and orientations [16,17].”
BackgroundCurrent multipole expansion to estimate lateral extent of neuronal activity: a theoretical analysis
Nolte, G., & Curio, G. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.871408 · Cited by 68
“In a multipole series, one describes the primary current by the moments of (in case of a scalar expansion) [2], [4], [7] or by moments of and (in case of dyadic expansion) [ 3 ]‐[5].”
BackgroundTamilia, E., Madsen, J., Grant, P., Pearl, P., & Papadelis, C. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00014 · Cited by 67
Magnetoencephalography in ellipsoidal geometry
Dassios, G., & Kariotou, F. (2003) · Journal of Mathematical Physics · doi:10.1063/1.1522135 · Cited by 67
Evaluation of multiple-sphere head models for MEG source localization
Lalancette, M., Quraan, M., & Cheyne, D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/17/010 · Cited by 65
“The presence of a silent source orientation in spherical conductors (the radial direction in this case) (Grynszpan and Geselowitz 1973) and more generally in ellipsoidal conductors (Dassios and Kariotou 2004) usually requires that inverse solutions constrain reconstructed sources to avoid obtaining…”
BackgroundMethodMultichannel SQUID Biomagnetic Systems
Vrba, J. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_2 · Cited by 63
“The magnetic field of an equivalent current dipole in a spherical medium can be computed analytically [62, 63].”
BackgroundMagnetic localisation of intracranial dipoles: simulation with a physical model.
Weinberg, H., Brickett, P., Coolsma, F., & Baff, M. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90109-4 · Cited by 62
Bowyer, S., Okada, Y., Papuashvili, N., Moran, J., Barkley, G., Welch, K., & Tepley, N. (1999) · Brain Research · doi:10.1016/s0006-8993(99)01892-2 · Cited by 60
Magnetic field associated with spreading depression: a model for the detection of migraine.
Okada, Y., Lauritzen, M., & Nicholson, C. (1988) · Brain Research · doi:10.1016/0006-8993(88)91450-3 · Cited by 60
MAGNETIC LOCATION OF CORTICAL ACTIVITY *
Williamson, S. (1980) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1982.tb50792.x · Cited by 58
Murakami, S., & Okada, Y. C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.003 · Cited by 55
“separating regions of differing electrical conductivities (Geselowitz, 1970; Geselowtitz, 1973; Grynszpan and Geselowitz, 1973; Plonsey, 1972).”
Somatotopic organization of the human somatosensory cortex revealed by neuromagnetic measurements
Okada, Y. C., Tanenbaum, R., Williamson, S. J., & Kaufman, L. (2004) · Experimental Brain Research · doi:10.1007/bf00236274 · Cited by 56
“Tile assumption that only the tangential component of the dipole contributes to B~ is based on the theoretical result obtained by Geselowitz (1970) and Grynszpan and Geselowitz (1973) for a spherical conducting medium whose conductivity may vary with radial distance from the center.”
BackgroundGencer, N., & Williamson, S. J. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686790 · Cited by 55
Advantages and limitations of magnetic source imaging
Williamson, S., Lu, Z.-L., Karron, D., & Kaufman, L. (2005) · Brain Topography · doi:10.1007/bf01132773 · Cited by 54
“The spherical model has provided a convenient simplification for modeling the pertinent region of the head when interpreting neuromagnetic data (Grynszpan and Geselowitz 1973; Cuffin and Cohen 1977).”
BackgroundInversion method for magnetoencephalography
Fokas, A., Gel'fand, I., & Kurylev, Y. (1996) · doi:10.1088/0266-5611/12/3/001 · Cited by 53
Magnetic field of the human sensorimotor cortex
Okada, Y. C., Williamson, S. J., & Kaufman, L. (1982) · International Journal of Neuroscience · doi:10.3109/00207458208985086 · Cited by 49
Source Cancellation Profiles of Electroencephalography and Magnetoencephalography
Irimia, A., Horn, J. V. V., & Halgren, E. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.104 · Cited by 52
“The most important difference in how signals are cancelled differently in EEG and MEG is a consequence of the fact that MEG is preferentially sensitive to source orientation (Cuffin, 1990; Grynszpan and Geselowitz, 1973; Hamalainen et al., 1993).”
Automatic activation in the human primary motor cortex synchronized with movement preparation
Endô, H., Kizuka, T., Masuda, T., & Takeda, T. (1999) · Cognitive Brain Research · doi:10.1016/s0926-6410(99)00024-5 · Cited by 48
Conductivities of Three-Layer Human Skull
Akhtari, M., Bryant, H., Mamelak, A. N. M., Heller, L., Shih, J. J., Mandelkern, M., Matlachov, A., Ranken, D., Best, E., & Sutherling, W. W. (2004) · Brain Topography · doi:10.1023/a:1007882102297 · Cited by 49
“…spherical shells, Boundary Element Model (BEM), and Finite Element Model (FEM) are among the most widely used (Fuchs et al. 1998; Buchner et al. 1997; Yan et al. 1991; Hämäläinen and Sarvas 1989; Sarvas 1987; Stock 1986; Meijs et al. 1985; Grynszpan and Gezelowitz 1973; Barnard et al. 1967).”
MethodInverse solutions based on MEG and EEG applied to volume conductor analysis.
Stok, C. J., Meijs, J. W. H., & Peters, M. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/015 · Cited by 49
Temporal structure of implicit motor imagery in visual hand‐shape discrimination as revealed by MEG
Kawamichi, H., Kikuchi, Y., Endo, H., Takeda, T., & Yoshizawa, S. (1998) · NeuroReport · doi:10.1097/00001756-199804200-00031 · Cited by 48
Tackling magnetoencephalography with particle swarm optimization
Parsopoulos, K. E., Kariotou, F., Dassios, G., & Vrahatis, M. N. (2009) · International Journal of Bio-Inspired Computation · doi:10.1504/ijbic.2009.022772 · Cited by 46
“This is possible by capturing and studying the magnetic fields produced by excitations of small regions of the brain, using sensor measurements (Bronzan, 1971; Dassios, 2006, 2007, 2008a, 2008b; Dassios and Fokas, 2008a; Dassios et al., 2005, 2007a, 2007b; Dassios and Kariotou, 2003a, 2003b, 2004, 2005; Fokas et al.,…”
MethodHuang, J.-C., Nicholson, C., & Okada, Y. C. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82635-7 · Cited by 46
“Because the secondary sources are directed normal to the boundary surface, the magnetic field due to the secondary sources at the scalp and skull should be parallel to their respective tangential plane of the boundary containing the secondary sources (Grynszpan and Geselowitz, 1973).”
BackgroundMagnetic evoked field associated with transcortical currents in turtle cerebellum.
Okada, Y., & Nicholson, C. (1988) · Biophysical Journal · doi:10.1016/s0006-3495(88)83153-9 · Cited by 46
Characterization of the human auditory cortex by the neuromagnetic method
Romani, G., Williamson, S., Kaufman, L., & Brenner, D. (2004) · Experimental Brain Research · doi:10.1007/bf00239356 · Cited by 45
Vrba, J., Robinson, S., McCubbin, J., Murphy, P., Eswaran, H., Wilson, J. D., Preissl, H., & Lowery, C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.10.022 · Cited by 44
Measurement of the human magnetic heart vector.
Barry, W. H., Fairbank, W., Harrison, D., Lehrman, K. L., Malmivuo, J., & Wikswo, J. (1977) · Science · doi:10.1126/science.929192 · Cited by 41
MEG source models and physiology.
Okada, Y., Lauritzen, M., & Nicholson, C. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/007 · Cited by 40
Dependence of the MEG on dipole orientation in the rabbit head.
Melcher, J., & Cohen, D. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90024-7 · Cited by 39
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 59
Laterality of human primary gustatory cortex studied by MEG.
Onoda, K., Kobayakawa, T., Ikeda, M., Saito, S., & Kida, A. (2005) · Chemical Sensors · doi:10.1093/chemse/bji059 · Cited by 38
“For estimates of the equivalent current dipoles (ECDs), we attempted to minimize the estimation error by using the equation of Grynszpan–Geselowitz (Grynszpan and Geselowitz, 1973).”
Spike and slow wave localization by magnetoencephalography.
Lewine, J., & Orrison, W. (1995) · Neuroimaging clinics of North America · doi:10.1016/s1052-5149(25)00325-9 · Cited by 38
Magnetic field associated with neural activities in an isolated cerebellum.
Okada, Y., Lauritzen, M., & Nicholson, C. (1987) · Brain Research · doi:10.1016/0006-8993(87)91451-x · Cited by 38
Ohtomo, S., Nakasato, N., Kanno, A., Hatanaka, K., Shirane, R., Mizoi, K., & Yoshimoto, T. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0168-5597(97)00065-8 · Cited by 37
The reliability of the fetal magnetocardiogram
Stinstra, J. (2001) · doi:10.3990/1.9789036516587 · Cited by 35
On cortical folds and neuromagnetic fields.
Kaufman, L., Kaufman, J. H., & Wang, J.-Z. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90139-u · Cited by 35
Chapman, R., Romani, G., Barbanera, S., Leoni, R., Modena, I., Ricci, G., & Campitelli, F. (1983) · Lettere al nuovo cimento della societa italiana di fisica/Lettere al nuovo cimento · doi:10.1007/bf02805209 · Cited by 35
Vatta, F., Bruno, P., & Inchingolo, P. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200201000-00001 · Cited by 32
“…of the effects of eccentric inhomogeneities on the EEG distribution has been accomplished almost only in terms of the forward problem (Cuffin, 1982; Grynszpan and Geselowitz, 1973; Kosugi et al., 1985; Ueno et al., 1987; van den Broek et al., 1998) and so, at present, there is a lack of…”
BackgroundLinear estimation theory applied to the reconstruction of a 3-D vector current distribution.
Smith, W. E., Dallas, W. J., Kullmann, W., & Schlitt, H. (1990) · Applied Optics · doi:10.1364/ao.29.000658 · Cited by 32
Effects of fissures in the brain on electroencephalograms and magnetoencephalograms
Cuffin, B. (1985) · doi:10.1063/1.335378 · Cited by 31
Round table. On the current multipole presentation of the primary current distributions
Katila, T. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455963 · Cited by 29
Hatanaka, K., Nakasato, N., Seki, K., Kanno, A., Mizoi, K., & Yoshimoto, T. (1997) · Tohoku journal of experimental medicine · doi:10.1620/tjem.182.9 · Cited by 27
Ahlfors, S. P., & Mody, M. (2016) · Organizational Research Methods · doi:10.1177/1094428116676344 · Cited by 27
“…the head are almost exclusively generated by primary currents oriented tangentially with respect to the inner surface of the skull, whereas MEG is insensitive to radially oriented primary currents (Ahlfors, Han, Belliveau, & Hamalainen, 2010; Cohen & Cuffin, 1983; Grynszpan & Geselowitz, 1973).”
Representation of Salty Taste Stimulus Concentrations in the Primary Gustatory Area in Humans
Kobayakawa, T., Saito, S., Gotow, N., & Ogawa, H. (2008) · Chemosensory Perception · doi:10.1007/s12078-008-9030-4 · Cited by 27
“In our estimation of ECDs, we attempted to minimize error by using Grynszpan–Geselowitz’s equation (Grynszpan and Geselowitz 1973; see Kobayakawa et al. 1996).”
MethodInferences concerning anatomy and physiology of the human brain based on its magnetic field
Okada, Y. C. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455940 · Cited by 24
The exterior magnetic field for the multilayer ellipsoidal model of the brain
Dassios, G., Giapalaki, S. N., Kandili, A. N., & Kariotou, F. (2007) · doi:10.1093/qjmam/hbl022 · Cited by 25
Kuriki, S., Murase, M., & Takeuchi, F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90259-9 · Cited by 23
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 23
Magnetocardiography: An Overview
Geselowitz, D. B. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326430 · Cited by 24
Self-citationSpatiotemporal imaging of complexity
Robinson, S. E., Mandell, A. J., & Coppola, R. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2012.00101 · Cited by 20
“(11) Suitable methods for computing forward solutions include the current dipole in a homogeneously conducting sphere model (Grynszpan and Geselowitz, 1973; Sarvas, 1987; Hari et al., 1988), multiple local spheres fitted to the surface of the head (Huang et al., 1999), boundary element methods (De…”
MethodShigeto, H., Tobimatsu, S., Morioka, T., Yamamoto, T., Kobayashi, T., & Kato, M. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00040-0 · Cited by 21
Magnetic fields of the human brain
Williamson, S., & Kaufman, L. (1980) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(80)90405-9 · Cited by 21
Magnetoencephalography signals are influenced by skull defects.
Lau, S., Flemming, L., & Haueisen, J. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.12.099 · Cited by 20
Metadata
- Authors
- Grynszpan, F., & Geselowitz, D. B.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1973-09
- Volume
- 13
- Issue
- 9
- Pages
- 911-925
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1484372
- OpenAlex
- W2017229769
- Cited by
- 226
- References
- 0
- Citations by year
- 2026: 2 · 2024: 2 · 2023: 5 · 2020: 1 · 2019: 6 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 4
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Keywords
- magnetocardiogram, quasi-static magnetic field, volume conductor, multipole expansion, axial symmetry, prolate spheroid, magnetic dipole moment, cardiac magnetic field
- MeSH terms
- Conductometry, Heart, Magnetics, Mathematics, Models, Theoretical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review