Electrically silent magnetic fields
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
There has been a significant controversy over the past decade regarding the relative information content of bioelectric and biomagnetic signals. In this paper we present a new, theoretical example of an electrically-silent magnetic field, based on a bidomain model of a cylindrical strand of tissue generalized to include off-diagonal components in the conductivity tensors. The physical interpretation of the off-diagonal components is explained, and analytic expressions for the electrical potential and the magnetic field are found. These expressions show that information not obtainable from electrical potential measurements can be obtained from measurements of the magnetic field in systems with conductivity tensors more complicated than those previously examined.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because the MCG is more sensitive to tangential cardiac currents and circular vortex currents and the ECG is more sensitive to the radial currents in principle (1, 17, 18), it is believed that the exercise MCG (eMCG) contains information complementary to the eECG (19, 20) and shows a better sensitivity to the deviations from the normal activation direction (21, 22).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [20]
In the citing paper
“a foundational research from the general theory of bioelectromagnetism describes the amount of potential additional information provided by MCG (1–7)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [5]
In the citing paper
“although theory and experimental research suggest and confirm that it can provide additional diagnostic information not achievable with electrocardiography alone (1, 2, 4–6, 9, 16, 107).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [5]
Citations
Cites
Electrodynamics of continuous media
Poots, G. (1961) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(61)90084-9 · Cited by 1,984
Gross morphology and fiber geometry of the heart
Streeter, D. D. (1979) · Medical Entomology and Zoology · Cited by 430
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
A bi-domain model for describing ischemic myocardial d-c potentials.
Tung, L. (1978) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 343
Geselowitz, D. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066765 · Cited by 318
A bidomain model for anisotropic cardiac muscle
Geselowitz, D. B., & Miller, W. T. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363286 · Cited by 273
The Extracellular Potential Field of the Single Active Nerve Fiber in a Volume Conductor
Clark, J., & Plonsey, R. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86524-5 · Cited by 183
The Four-Electrode Resistivity Technique as Applied to Cardiac Muscle
Plonsey, R., & Barr, R. C. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324927 · Cited by 120
Peachey, L. D., & Eisenberg, B. R. (1978) · Biophysical Journal · doi:10.1016/s0006-3495(78)85480-0 · Cited by 103
A Bidomain Model for the Extracellular Potential and Magnetic Field of Cardiac Tissue
Roth, B. J., & Wikswo, J. P. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325804 · Cited by 89
Self-citation
Cited by
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Self-citationDipole models for the EEG and MEG
Schimpf, P. H., Ramon, C., & Haueisen, J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995679 · Cited by 156
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
A Bidomain Model Based BEM-FEM Coupling Formulation for Anisotropic Cardiac Tissue
Fischer, G., TILG, B., Modre, R., Huiskamp, G. J. M., Fetzer, J., Rucker, W. M., & Wach, P. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1318927 · Cited by 118
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
“1) Beats/min 119(2) 117(6) 142(1) 118(2) 133(2)”
Metadata
- Authors
- Roth, B. J., & Wikswo, J. P.
- Affiliations
- Vanderbilt University (US)
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1986-10
- Volume
- 50
- Issue
- 4
- Pages
- 739-745
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1329851
- OpenAlex
- W1976341739
- Cited by
- 57
- References
- 21
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 3
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 9785 d)
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Office of Naval Research (N00014-82-K-0107)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysical and Geoelectrical Methods
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- biomagnetic signals, bioelectric signals, bidomain model, anisotropic conductivity, electric potential, magnetic field
- MeSH terms
- Action Potentials, Magnetics, Mathematics, Membrane Potentials, Models, Biological, Potentiometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrically silent magnetic fields. https://app.cochat.ai/papers/10.1016/s0006-3495(86)83513-5
- The paper
- Roth, B. J., & Wikswo, J. P. (1986). Electrically silent magnetic fields. Biophysical Journal. https://doi.org/10.1016/s0006-3495(86)83513-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.