The DOI matches its Crossref record.
Determination of bilayer membrane bending stiffness by tether formation from giant, thin-walled vesicles
Open accessAbstract
The curvature elastic modulus (bending stiffness) of stearoyloleoyl phosphatidylcholine (SOPC) bilayer membrane is determined from membrane tether formation experiments. R. E. Waugh and R. M. Hochmuth 1987. Biophys. J. 52:391-400) have shown that the radius of a bilayer cylinder (tether) is inversely related to the force supported along its axis. The coefficient that relates the axial force on the tether to the tether radius is the membrane bending stiffness. Thus, the bending stiffness can be calculated directly from measurements of the tether radius as a function of force. Giant (10-50-microns diam) thin-walled vesicles were aspirated into a micropipette and a tether was pulled out of the surface by gravitational forces on small glass beads that had adhered to the vesicle surface. Because the vesicle keeps constant surface area and volume, formation of the tether requires displacement of material from the projection of the vesicle in the pipette. Tethers can be made to grow longer or shorter or to maintain equilibrium by adjusting the aspiration pressure in the micropipette at constant tether force. The ratio of the change in the length of the tether to the change in the projection length is proportional to the ratio of the pipette radius to the tether radius. Thus, knowing the density and diameter of the glass beads and measuring the displacement of the projection as a function of tether length, independent determinations of the force on the tether and the tether radius were obtained. The bending stiffness for an SOPC bilayer obtained from these data is approximately 2.0 x 10(-12) dyn cm, for tether radii in the range of 20-100 nm. An equilibrium relationship between pressure and tether force is derived which closely matches experimental observation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Seifert, U., Berndl, K., & Lipowsky, R. (1991) · Physical Review A · doi:10.1103/physreva.44.1182 · Cited by 963
Cellular motions and thermal fluctuations: the Brownian ratchet
Peskin, C. S., Odell, G. M., & Oster, G. F. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81035-x · Cited by 889
Recent developments in the field of bending rigidity measurements on membranes
Dimova, R. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2014.03.003 · Cited by 503
Siegel, D. P. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81256-6 · Cited by 399
Metadata
- Authors
- Bo, L., & Waugh, R. E.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1989-03
- Volume
- 55
- Issue
- 3
- Pages
- 509-517
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2020152035
- Cited by
- 212
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of bilayer membrane bending stiffness by tether formation from giant, thin-walled vesicles. https://app.cochat.ai/papers/10.1016/s0006-3495(89)82844-9
- The paper
- Bo, L., & Waugh, R. E. (1989). Determination of bilayer membrane bending stiffness by tether formation from giant, thin-walled vesicles. Biophysical Journal. https://doi.org/10.1016/s0006-3495(89)82844-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.