Dynamics of neutrophil rolling over stimulated endothelium in vitro
Open accessThe DOI matches its Crossref record.
Abstract
Prior to extravasation at sites of acute inflammation, neutrophils roll over activated endothelium. Neutrophil rolling is often characterized by the average rolling velocity. An additional dynamic feature of rolling that has been identified but not extensively studied is the fluctuation in the rolling velocity about the average. To analyze this characteristic further, we have measured the instantaneous velocity of bovine neutrophils interacting with lipopolysaccharide-stimulated bovine aortic endothelium at shear stresses of 1, 2, 3, and 4 dynes/cm2. The average velocities are quantitatively similar to those reported for human neutrophils rolling over reconstituted P-selectin at a surface density of 400 sites/microns 2. At all shear stresses tested, the population average variance in the instantaneous velocity is at least 2 orders of magnitude higher than the theoretical variance generated from experimental error, indicating that the neutrophils translate with a nonconstant velocity. Possible sources of the variance are discussed. These include "macroscopic" sources such as topological heterogeneity in the endothelium and microscopic sources, such as inherent stochastic formation and breakage of the receptor-ligand bonds that mediate the rolling. Regardless of the ultimate source of the variance, these results justify the use of mathematical models that incorporate stochastic processes to describe bond formation and breakage between the neutrophil and the endothelium and hence are able to generate variable velocity trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reactive Oxygen Species in Inflammation and Tissue Injury
Mittal, M., Siddiqui, M. R., Tran, K., Reddy, S. P., & Malik, A. B. (2014) · Antioxidants & Redox Signaling · doi:10.1089/ars.2012.5149 · Cited by 4,897
Mesenchymal Stem Cell Homing: The Devil Is in the Details
Karp, J. M., & Leng Teo, G. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.02.001 · Cited by 1,445
“To provide context, leukocyte rolling has been typically observed to be less than 5 mm/s at shear stresses up to 4 dynes/cm2 (Goetz et al., 1994; Ley et al., 2007).”
The nonlinear nature of friction
Urbakh, M., Klafter, J., Gourdon, D., & Israelachvili, J. (2004) · Nature · doi:10.1038/nature02750 · Cited by 696
“This behaviour has been successfully modelled in terms of the thermally controlled binding and unbinding of specific ligand–receptor bonds on the two surface”
BackgroundThe state diagram for cell adhesion under flow: Leukocyte rolling and firm adhesion
Chang, K.-C., Tees, D. F. J., & Hammer, D. A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.200240897 · Cited by 273
Self-citationSchmid-Schönbein, G. W. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095708 · Cited by 253
Metadata
- Authors
- Goetz, D. J., el-Sabban, M. E., Pauli, B. U., & Hammer, D. A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1994-06
- Volume
- 66
- Issue
- 6
- Pages
- 2202-2209
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2052282667
- Cited by
- 70
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamics of neutrophil rolling over stimulated endothelium in vitro. https://app.cochat.ai/papers/10.1016/s0006-3495(94)81016-1
- The paper
- Goetz, D. J., el-Sabban, M. E., Pauli, B. U., & Hammer, D. A. (1994). Dynamics of neutrophil rolling over stimulated endothelium in vitro. Biophysical Journal. https://doi.org/10.1016/s0006-3495(94)81016-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.