Cited by 181Advanced Fluorescence Microscopy TechniquesNonlinear Optical Materials StudiesPhotochromic and Fluorescence Chemistry

Photolysis of Caged Calcium in Femtoliter Volumes Using Two-Photon Excitation

Open access
Brown, Edward B., Shear, Jason B., Adams, Stephen R., Tsien, Roger Y., Webb, Watt W.·1999·Biophysical Journal

Abstract

A new technique for the determination of the two-photon uncaging action cross section (deltau) of photolyzable calcium cages is described. This technique is potentially applicable to other caged species that can be chelated by a fluorescent indicator dye, as well as caged fluorescent compounds. The two-photon action cross sections of three calcium cages, DM-nitrophen, NP-EGTA, and azid-1, are studied in the range of excitation wavelengths between 700 and 800 nm. Azid-1 has a maximum deltau of approximately 1.4 GM at 700 nm, DM-nitrophen has a maximum deltau of approximately 0.013 GM at 730 nm, and NP-EGTA has no measurable uncaging yield. The equations necessary to predict the amount of cage photolyzed and the temporal behavior of the liberated calcium distribution under a variety of conditions are derived. These equations predict that by using 700-nm light from a Ti:sapphire laser focused with a 1.3-NA objective, essentially all of the azid-1 within the two-photon focal volume would be photolyzed with a 10-micros pulse train of approximately 7 mW average power. The initially localized distributions of free calcium will dissipate rapidly because of diffusion of free calcium and uptake by buffers. In buffer-free cytoplasm, the elevation of the calcium concentration at the center of the focal volume is expected to last for approximately 165 micros.

Integrity signals

Registry

Crossref · 10.1016/s0006-3495(99)77217-6

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The two-photon action cross section of MNI-glutamate is 0.06 GM at 730 nm, determined using azid-1 as a standard compound with a known action cross section of 1.0 GM at 730 nm.

    “The two-photon action cross section of MNI-glutamate was obtained as 0.06 GM at 730 nm, using azid-1 as a standard compound with a known action cross section of 1.0 GM at 730 nm48.”

Cited by

Sorted by citations

Authors
Brown, E. B., Shear, J. B., Adams, S. R., Tsien, R. Y., & Webb, W. W.
Affiliations
  • Cornell University (US)
  • The University of Texas at Austin (US)
  • Howard Hughes Medical Institute (US)
Corresponding author
Webb, Watt W.
Venue
Biophysical Journal
Publisher
Elsevier BV
Published
1999-01
Volume
76
Issue
1
Pages
489-499
ISSN
0006-3495 (ISSN-L)
OpenAlex
W2142720148
Cited by
181
References
0
Citations by year
2025: 4 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 2 · 2019: 5 · 2018: 5 · 2017: 3 · 2016: 1 · 2015: 11 · 2014: 13 · 2013: 6 · 2012: 7
FWCI
4.73
Type
journal article
Language
en
Open access
Locations
  • Biophysical Journal (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01rr007719-03)
  • National Institute of General Medical Sciences (T32 GM 08267, T32GM008267)
  • National Center for Research Resources (RR07719, RR04224, P41RR004224)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Nonlinear Optical Materials Studies
  • Physical Sciences › Materials Science › Materials Chemistry › Photochromic and Fluorescence Chemistry
Keywords
caged calcium, two-photon uncaging, calcium diffusion, calcium indicator dyes, photolysis kinetics
MeSH terms
Acetates, Biophysics, Calcium, Chelating Agents, Egtazic Acid, Ethylenediamines, Kinetics, Models, Chemical, Photolysis, Photons, Biophysical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review