CoChat

Gender-related differences in left ventricular chamber function

Hayward, C · 2001 · Cardiovascular Research
Cited by 156

The DOI matches its Crossref record.

Abstract

OBJECTIVES: While women have lower rates of atherosclerotic disease than men, they are more likely to suffer cardiac failure following infarction or cardiac surgery, despite typically having a greater left ventricular (LV) ejection fraction. We hypothesised that gender differences in systolic chamber function and ventriculo-vascular coupling may contribute to these clinical findings. METHODS: LV chamber function was determined in a cohort of 30 patients (16 women) aged 48-75 years with normal LV function using pressure-volume loops obtained by simultaneous conductance catheter volumetry and micromanometer pressure. End-systolic and end-diastolic pressure volume (ESPVR, EDPVR) and preload recruitable stroke work relations (PRSWR) were derived. Results were analysed according to gender, and the effects of body size and chamber dimensions were examined. RESULTS: The groups were closely matched for age (60+/-6 vs. 60+/-8 years) and co-morbid conditions. Women had higher end-systolic blood pressure (139.7+/-21.1 vs. 123.6+/-12.6 mmHg, P=0.001), and smaller LV cavity volume (end-diastolic volume 96.4+/-30.6 vs. 139+/-30.7 ml, P=0.001). Women had significantly higher LV end-systolic elastance (Ees, 2.65+/-0.10 vs. 1.96+/-0.09 mmHg ml(-1), P<0.002), arterial elastance (2.41+/-1.13 vs. 1.54+/-0.55 mmHg ml(-1), P=0.01) and lower passive LV diastolic compliance (slope EDPVR, 6.12+/-0.37 vs. 10.0+/-0.50 ml mmHg(-1), P<0.001). While there was a strong relationship between end-systolic elastance and chamber volume (r=0.69, P<0.001), gender differences in chamber function all persisted after indexing to body size. Higher LV systolic function in women was also shown in PRSWR analysis (slope, M(SW); 101.4+/-3.8 vs. 90.4+/-2.8 mmHg, P<0.05), which is independent of chamber size. After normalising volumes to resting diastolic volume, the greater systolic and diastolic elastance in women was accounted for. The ratio of end-systolic to arterial elastance, a measure of ventriculo-vascular coupling, was similar in women and men (1.19+/-0.40 vs. 1.54+/-0.30, respectively, P=0.23). CONCLUSIONS: This study demonstrates greater systolic chamber function and lower diastolic compliance in women. Within the range of chamber dimensions seen in patients with normal LV function, a strong relationship was found between cardiac size and end-systolic elastance. While these differences were not accounted for by indexing to body size, the greater ventricular elastance in women was removed after normalising to chamber size. Despite differences in resting ventricular elastance, appropriate ventriculo-vascular coupling was maintained in both genders as the greater end-systolic elastance in women was matched by similarly elevated arterial elastance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(00)00280-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 156

Metadata

Authors
Hayward, C.
Venue
Cardiovascular Research
Published
2001-02-01
Volume
49
Issue
2
Pages
340-350
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2030436321
Cited by
156
References
0
FWCI
2.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gender-related differences in left ventricular chamber function. https://app.cochat.ai/papers/10.1016/s0008-6363(00)00280-7
The paper
Hayward, C. (2001). Gender-related differences in left ventricular chamber function. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(00)00280-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.