The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Methods of collecting and evaluating non-clinical cardiac electrophysiology data in the pharmaceutical industry: results of an international survey
Abstract
OBJECTIVE: To assess current practice in the pharmaceutical industry for assessing the potential for QT interval prolongation by non-cardiovascular medicinal products. METHODS: The survey was based on responses from the Toxicology and (Safety) Pharmacology laboratories (a total of 74 laboratories) of 54 companies based in Europe, Japan/Asia and the USA, received between January and March 1999. RESULTS: All 54 companies conducted preclinical in vivo electrocardiography (EGG) evaluation of new active substances (NASs). Thirty of these companies also conducted in vitro cardiac electrophysiology studies on their compounds. The majority of in vivo work was done in conscious beagle dogs. There was no consistency within the industry in defining the magnitude of change in QT interval that is considered biologically important. Most companies considered a change greater than 10% to be important, although the design of the studies suggested that group sizes used may not give sufficient statistical power to detect this size of change. Bazett's formula was used by 41% of laboratories to correct QT for changes in heart rate, despite the fact that this formula is generally deemed to be unsuitable for use in dogs. For studies in anaesthetised dogs, the majority of laboratories used barbiturate anaesthesia, but researchers should be aware of the effects of this and some other anaesthetic agents on QT interval. As for in vitro cardiac electrophysiology, there was wide diversity in the testing methodologies, particularly with regard to the test species and tissue type. As with QT prolongation, there was no consensus on the degree of action potential prolongation to cause concern. For both in vitro and in vivo testing, the majority of companies tested a minimum of three dose (or concentration) levels in order to ascertain any dose-response relationship. CONCLUSIONS: The survey provides a snapshot of the practice in the industry prior to any internationally-agreed consensus on the most effective and efficient approaches to minimising the risk of QT prolongation by new drugs in man. It must be stated that for any given methodology, the 'majority view' in the industry is not necessarily best practice.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Three separate surveys of the pharmaceutical industry revealed that canine was the most commonly used animal model for evaluation and determination of QT interval prolongation of novel compounds (Friedrichs, Patmore, & Bass, 2005; Hammond, et al., 2001; Lindgren, et al., 2008).”
From Small and large animal models in cardiac contraction research: advantages and disadvantages (2014) · cites this paper as Hammond, et al., 2001
Citations
Cites
The pharmacological basis of therapeutics
Starr, I. (1941) · American Heart Journal · doi:10.1016/s0002-8703(41)90958-4 · Cited by 1,907
Haverkamp*, W. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00119-x · Cited by 486
An improved method to correct the QT interval of the electrocardiogram for changes in heart rate
de Water, A. V., Verheyen, J., Xhonneux, R., & Reneman, R. S. (1989) · Journal of Pharmacological Methods · doi:10.1016/0160-5402(89)90015-6 · Cited by 318
Tande, P. M., Bjørnstad, H., Yang, T., & Refsum, H. (1990) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199009000-00008 · Cited by 177
Tissue and Species Distribution of mRNA for the ikr-like K+Channel, ERG
Wymore, R. S., Gintant, G. A., Wymore, R. T., Dixon, J. E., McKinnon, D. H., & Cohen, I. S. (1997) · Circulation Research · doi:10.1161/01.res.80.2.261 · Cited by 168
Dukes, I. D., Cleemann, L. N., & Morad, M. (1990) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)12766-3 · Cited by 155
Shimizu, W., McMAHON, B., & Antzelevitch, C. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00656.x · Cited by 133
Keegan, R. D., & Greene, S. A. (1993) · Veterinary Surgery · doi:10.1111/j.1532-950x.1993.tb00434.x · Cited by 100
QT corrected for heart rate and relation between QT and RR intervals in beagle dogs
Matsunaga, T., Mitsui, T., Harada, T., Inokuma, M., Murano, H., & Shibutani, Y. (1997) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(97)00098-1 · Cited by 85
The effects of midazolam or propofol followed by suxamethonium on the QT interval in humans
Michaloudis, D., Kanakoudis, F., Petrou, A., Konstantinidou, A. S., & Pollard, B. J. (1996) · European Journal of Anaesthesiology · doi:10.1046/j.1365-2346.1996.00022.x · Cited by 71
Cited by
Sorted by citations
REDFERN, W., Carlsson, L. G., DAVIS, A., LYNCH, W., MACKENZIE, I., PALETHORPE, S., Siegl, P. K. S., Strang, I., Sullivan, A. K., & WALLIS, R. (2003) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00846-5 · Cited by 1,535
Small and large animal models in cardiac contraction research: advantages and disadvantages
Milani-Nejad, N., & Janssen, P. M. L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.007 · Cited by 484
Safety of Non-Antiarrhythmic Drugs that Prolong the QT Interval or Induce Torsade de Pointes
Ponti, F. D., Poluzzi, E., Cavalli, A., Recanatini, M., & Montanaro, N. (2002) · Drug Safety · doi:10.2165/00002018-200225040-00004 · Cited by 309
Recanatini, M., Poluzzi, E., Masetti, M., Cavalli, A., & Ponti, F. D. (2004) · Medicinal Research Reviews · doi:10.1002/med.20019 · Cited by 290
The significance of QT interval in drug development
Shah, R. R. (2002) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2002.01627.x · Cited by 231
Metadata
- Authors
- Hammond, T.
- Affiliations
- AstraZeneca (United Kingdom) (GB)
- Corresponding author
- Hammond, T
- ORCID
- Hammond, T
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03
- Volume
- 49
- Issue
- 4
- Pages
- 741-750
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2004833283
- Cited by
- 117
- References
- 24
- Citations by year
- 2026: 1 · 2024: 4 · 2023: 1 · 2021: 1 · 2020: 1 · 2019: 4 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 3 · 2014: 1 · 2013: 10 · 2012: 3
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Cardiovascular Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Pharmaceutical studies and practices
- Keywords
- QT prolongation, cardiac safety assessment, beagle dogs, Bazett formula, barbiturate anesthesia, action potential prolongation, dose-response relationship, drug safety
- MeSH terms
- Action Potentials, Animals, Animals, Laboratory, Data Interpretation, Statistical, Dogs, Dose-Response Relationship, Drug, Drug Industry, Drug Evaluation, Preclinical, Electrocardiography, Papillary Muscles, Purkinje Fibers, Research Design, Models, Animal, Rats, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review