CoChat

Block of impulse propagation at an abrupt tissue expansion: evaluation of the critical strand diameter in 2- and 3-dimensional computer models

Open access
Fast, V. G., Kleber, A. G. · 1995 · Cardiovascular Research
Cited by 100

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Unidirectional conduction block in the heart can occur at a site where the impulse is transmitted from a small to a large tissue volume. The aim of this study was to evaluate the occurrence of conduction block in a 2-dimensional and 3-dimensional computer model of cardiac tissue consisting of a narrow strand abruptly emerging into a large area. In this structure, the strand diameter critical for the occurrence of block, hc, was evaluated as a function of changes in the active and passive electrical properties of both the strand and the large medium. METHODS: The effects of changes in the following parameters on hc were analysed: (1) maximum sodium conductance (gNamax), (2) longitudinal (Rx) and transverse (Ry) intracellular resistivities, and (3) inhomogeneities in gNamax and Rx and Ry between the strand and the large area. Three ionic models for cardiac excitation described by Beeler-Reuter, Ebihara-Johnson, and Luo-Rudy ionic current kinetics were compared. RESULTS: In the 2-dimensional simulations, hc was 175 microns in Ebihara-Johnson and Beeler-Reuter models and 200 microns in the Luo-Rudy model. At the critical strand diameter, the site of conduction block was located beyond the transition, i.e. a small circular area was activated in the large medium, whereas with narrower strands conduction block occurred within the strands. The decrease of gNamax resulted in a large increase of hc. This increase was mainly due to the change of gNamax in the large area, while hc was almost independent of gNamax in the strand. Changing Rx had no effect on hc, whereas the increase of Ry decreased hc and reversed conduction block. Inhomogeneous changes of Rx and Ry in the strand versus the large medium had opposite effects on hc. When the resistivities of the strand alone were increased, hc also increased. In contrast, the increase of the resistivities in the large area reduced hc. In the 3-dimensional model, hc was 2.7 times larger than the corresponding 2-dimensional values at the various levels of gNamax and resistivity. CONCLUSIONS: (1) At physiological values for active and passive electrical properties, hc in the 2D simulations is close to 200 microns in all three ionic models. In the 3-dimensional simulations, hc is 2.7 larger than in the 2-dimensional models. (2) The excitable properties of the large area but not of the strand modify hc. The decrease of intercellular coupling in the large medium facilitates impulse conduction and reduces hc, while the same change in the strand increases hc. (3) Occurrence of conduction block at an abrupt geometrical transition can be explained by both the impedance mismatch at the transition site and the critical curvature beyond the transition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(95)00071-2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 100

Metadata

Authors
Fast, V. G., & Kleber, A. G.
Venue
Cardiovascular Research
Published
1995-09-01
Volume
30
Issue
3
Pages
449-459
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2067860260
Cited by
100
References
0
FWCI
2.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Block of impulse propagation at an abrupt tissue expansion: evaluation of the critical strand diameter in 2- and 3-dimensional computer models. https://app.cochat.ai/papers/10.1016/s0008-6363(95)00071-2
The paper
Fast, V. G., & Kleber, A. G. (1995). Block of impulse propagation at an abrupt tissue expansion: evaluation of the critical strand diameter in 2- and 3-dimensional computer models. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(95)00071-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.