Bicoherence of intracranial EEG in sleep, wakefulness and seizures

Open access
Bullock, T.H., Achimowicz, J.Z., Duckrow, R.B., Spencer, S.S., Iragui-Madoz, V.J. · 1997 · Electroencephalography and Clinical Neurophysiology
Cited by 70

The DOI matches its Crossref record.

Abstract

The hypothesis that the intracranial EEG has local structure and short-term non-stationarity is tested with a little-studied measure of non-linear phase coupling, the bicoherence in human subdural and deep temporal lobe probe data from 11 subjects during sleeping, waking and seizure states. This measure of cooperativity estimates the proportion of energy in every possible pair of frequency components, F1, F2 (from 1 to 50 Hz in this study), that satisfies the definition of quadratic phase coupling (phase of component at F3, which is F1 + F2, equals phase of F1 + phase of F2). Derived from the bispectrum, which segregates the non-Gaussian energy, auto-bicoherence uses the frequency components in one channel; cross-bicoherence uses one channel for F1 and F2 and another for F3. These higher order spectra are used in physical systems for detection of episodes of non-linearity and transients, for pattern recognition and robust classification, relatively immune to Gaussian components and low signal to noise ratios. Bicoherence is found not to be a fixed character of the EEG but quite local and unstable, in agreement with the hypothesis. Bicoherence can be quite different in adjacent segments as brief as 1.6 s as well as adjacent intracranial electrodes as close as 6.5 mm, even when the EEG looks similar. It can rise or fall steeply within millimeters. It is virtually absent in many analysis epochs of 17s duration. Other epochs show significant bicoherence with diverse form and distribution over the bifrequency plane. Isolated peaks, periodic peaks or rounded mountain ranges are either widely scattered or confined to one or a few parts of the plane. Bicoherence is generally an invisible feature: one cannot usually recognize the responsible form of non-linearity or any obvious correlate in the raw EEG. During stage II/III sleep overall mean bicoherence is generally higher than in the waking state. During seizures the diverse EEG patterns average a significant elevation in bicoherence but have a wide variance. Maximum bispectrum, maximum power spectrum, maximum and mean bicoherence, skewness and asymmetry all vary independently of each other. Cross-bicoherence is often intermediate between the two auto-bicoherence spectra but commonly resembles one of the two. Of the known factors that contribute to bicoherence, transient as distinct from ongoing wave forms can be more important in our data sets. This measure of non-linear higher moments is very sensitive to weak quadratic phase coupling; this can come from several kinds of waveforms. New methods are needed to evaluate their respective contributions. Utility of this descriptor cannot be claimed before more carefully defined and repeatable brain states are studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0013-4694(97)00087-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
Bullock, T. H., Achimowicz, J. Z., Duckrow, R. B., Spencer, S. S., & Iragui-Madoz, V. J.
Venue
Electroencephalography and Clinical Neurophysiology
Publisher
Elsevier BV
Published
1997-12
Volume
103
Issue
6
Pages
661-678
ISSN
0013-4694 (ISSN-L)
OpenAlex
W2019014211
Cited by
70
References
0
FWCI
0.67
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bicoherence of intracranial EEG in sleep, wakefulness and seizures. https://app.cochat.ai/papers/10.1016/s0013-4694(97)00087-4
The paper
Bullock, T. H., Achimowicz, J. Z., Duckrow, R. B., Spencer, S. S., & Iragui-Madoz, V. J. (1997). Bicoherence of intracranial EEG in sleep, wakefulness and seizures. Electroencephalography and Clinical Neurophysiology. https://doi.org/10.1016/s0013-4694(97)00087-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.