Bicoherence of intracranial EEG in sleep, wakefulness and seizures
Open accessThe DOI matches its Crossref record.
Abstract
The hypothesis that the intracranial EEG has local structure and short-term non-stationarity is tested with a little-studied measure of non-linear phase coupling, the bicoherence in human subdural and deep temporal lobe probe data from 11 subjects during sleeping, waking and seizure states. This measure of cooperativity estimates the proportion of energy in every possible pair of frequency components, F1, F2 (from 1 to 50 Hz in this study), that satisfies the definition of quadratic phase coupling (phase of component at F3, which is F1 + F2, equals phase of F1 + phase of F2). Derived from the bispectrum, which segregates the non-Gaussian energy, auto-bicoherence uses the frequency components in one channel; cross-bicoherence uses one channel for F1 and F2 and another for F3. These higher order spectra are used in physical systems for detection of episodes of non-linearity and transients, for pattern recognition and robust classification, relatively immune to Gaussian components and low signal to noise ratios. Bicoherence is found not to be a fixed character of the EEG but quite local and unstable, in agreement with the hypothesis. Bicoherence can be quite different in adjacent segments as brief as 1.6 s as well as adjacent intracranial electrodes as close as 6.5 mm, even when the EEG looks similar. It can rise or fall steeply within millimeters. It is virtually absent in many analysis epochs of 17s duration. Other epochs show significant bicoherence with diverse form and distribution over the bifrequency plane. Isolated peaks, periodic peaks or rounded mountain ranges are either widely scattered or confined to one or a few parts of the plane. Bicoherence is generally an invisible feature: one cannot usually recognize the responsible form of non-linearity or any obvious correlate in the raw EEG. During stage II/III sleep overall mean bicoherence is generally higher than in the waking state. During seizures the diverse EEG patterns average a significant elevation in bicoherence but have a wide variance. Maximum bispectrum, maximum power spectrum, maximum and mean bicoherence, skewness and asymmetry all vary independently of each other. Cross-bicoherence is often intermediate between the two auto-bicoherence spectra but commonly resembles one of the two. Of the known factors that contribute to bicoherence, transient as distinct from ongoing wave forms can be more important in our data sets. This measure of non-linear higher moments is very sensitive to weak quadratic phase coupling; this can come from several kinds of waveforms. New methods are needed to evaluate their respective contributions. Utility of this descriptor cannot be claimed before more carefully defined and repeatable brain states are studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Top-down processing mediated by interareal synchronization
von Stein, A., Chiang, C., & König, P. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14748 · Cited by 729
Subha, D. P., Joseph, P. K., Acharya U, R., & Lim, C. M. (2010) · Journal of Medical Systems · doi:10.1007/s10916-008-9231-z · Cited by 627
Electroencephalographic measurement of motor cortex control of muscle activity in humans
Mima, T., Steger, J., Schulman, A. E., Gerloff, C., & Hallett, M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00229-1 · Cited by 282
Phase-coupling of theta–gamma EEG rhythms during short-term memory processing
Schack, B., Vath, N., Petsche, H., Geissler, H.-G., & Möller, E. (2002) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(01)00199-4 · Cited by 281
Bruns, A., & Eckhorn, R. (2004) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2003.07.001 · Cited by 224
Metadata
- Authors
- Bullock, T. H., Achimowicz, J. Z., Duckrow, R. B., Spencer, S. S., & Iragui-Madoz, V. J.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-12
- Volume
- 103
- Issue
- 6
- Pages
- 661-678
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2019014211
- Cited by
- 70
- References
- 0
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bicoherence of intracranial EEG in sleep, wakefulness and seizures. https://app.cochat.ai/papers/10.1016/s0013-4694(97)00087-4
- The paper
- Bullock, T. H., Achimowicz, J. Z., Duckrow, R. B., Spencer, S. S., & Iragui-Madoz, V. J. (1997). Bicoherence of intracranial EEG in sleep, wakefulness and seizures. Electroencephalography and Clinical Neurophysiology. https://doi.org/10.1016/s0013-4694(97)00087-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.