A generalized correlation for evaporation heat transfer of refrigerants in micro-fin tubes
The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An empirical experimental correlation for the vapor quality region is used for the refrigerant-side heat-transfer coefficient, hr [23]. This correlation is applicable to a variety of refrigerants, micro-fins, and tubes suitable for evaporators in ASHPs.”
From Performance prediction of a fin-and-tube heat exchanger considering air-flow reduction due to the frost accumulation (2013) · cites this paper as [23]
Citations
Cites
A general correlation for flow boiling in tubes and annuli
Gungor, K. E., & Winterton, R. H. S. (1986) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(86)90205-x · Cited by 1,275
Calculation of void volume fraction in the subcooled and quality boiling regions
Rouhani, S. Z., & Axelsson, E. (1970) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(70)90114-6 · Cited by 787
Boiling of new refrigerants: a state-of-the-art review
Thome, J. R. (1996) · International Journal of Refrigeration · doi:10.1016/s0140-7007(96)00004-7 · Cited by 197
A Model for Correlating Flow Boiling Heat Transfer in Augmented Tubes and Compact Evaporators
Kandlikar, S. G. (1991) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2911229 · Cited by 113
Condensation heat transfer and flow pattern inside a herringbone-type micro-fin tube
Miyara, A., Nonaka, K., & Taniguchi, M. (2000) · International Journal of Refrigeration · doi:10.1016/s0140-7007(99)00037-7 · Cited by 100
Evaporation heat transfer characteristics of R-410A in 7 and 9.52 mm smooth/micro-fin tubes
Kim, Y., Seo, K., & Chung, J. T. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00070-6 · Cited by 84
Self-citationAdvanced micro-fin tubes for evaporation
Chamra, L. M., Webb, R. L., & Randlett, M. R. (1996) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(95)00276-6 · Cited by 75
Schlager, L. M., Pate, M. B., & Bergles, A. E. (1989) · International Journal of Refrigeration · doi:10.1016/0140-7007(89)90006-6 · Cited by 72
Evaporation heat transfer and pressure drop of R-22 in 7 and 9.52 mm smooth/micro-fin tubes
Seo, K., & Kim, Y. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00338-5 · Cited by 45
Self-citationForced Convective Boiling of Nonazeotropic Refrigerant Mixtures Inside Tubes
Murata, K., & Hashizume, K. (1993) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2910739 · Cited by 44
Evaporation in Microfin Tubes: A Generalized Prediction Model.
Thome, J. R., Favrat, D., & Kattan, N. (1997) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 41
Muzzio, A., Niro, A., & Arosio, S. (1998) · Enhanced heat transfer/Journal of enhanced heat transfer · doi:10.1615/jenhheattransf.v5.i1.40 · Cited by 30
A Comparison of Augmentation Techniques During In-Tube Evaporation of R-113
Reid, R. S., Pate, M. B., & Bergles, A. E. (1991) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2910582 · Cited by 29
Predicting Flow Boiling Heat Transfer of Refrigerants in Microfin Tubes
Raykoff, T., & Kandlikar, S. G. (1997) · Enhanced heat transfer/Journal of enhanced heat transfer · doi:10.1615/jenhheattransf.v4.i4.20 · Cited by 22
Condensation and Evaporation in Micro-fin Tubes at Equal Saturation Temperatures
Chamra, L. M., & Webb, R. L. (1995) · Enhanced heat transfer/Journal of enhanced heat transfer · doi:10.1615/jenhheattransf.v2.i3.50 · Cited by 20
Flow Boiling Heat Transfer Coefficients of R-134a in a Microfin Tube
Singh, A., Ohadi, M. M., & Dessiatoun, S. V. (1996) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2825877 · Cited by 20
In-tube Evaporation and Condensation of R-22 and R-410A with Plain and Internally Enhanced Tubes
Bogart, J., & Thors, P. (1999) · Enhanced heat transfer/Journal of enhanced heat transfer · doi:10.1615/jenhheattransf.v6.i1.40 · Cited by 16
Effect of Heating Boundary Conditions on Pool Boiling Experiments
Darabi, J., Ohadi, M. M., Fanni, M. A., Dessiatoun, S. V., & Kedzierski, M. A. (1999) · Science and Technology for the Built Environment · doi:10.1080/10789669.1999.10391239 · Cited by 15
Goto, M., Inoue, N., & Koyama, K. (1997) · Medical Entomology and Zoology · Cited by 9
Research works printed but not linked: 3
- Khanpara, 1987, Local evaporation heat transfer in a smooth tube and a micro-fin tube using refrigerants 22 and 113, Boiling Condensation Heat Transfer Equip., 85, 31
- Khanpara, 1987, A comparison of in-tube evaporation of refrigerant 113 in electrically heated and fluid heated smooth and inner-fin tubes, Adv. Enhanced Heat Transfer, 68, 35
- Itoh, 1997, Enhancement of condensation in a horizontal micro-fin tube for zeotropic refrigerant mixtures, Oji Int. Seminar, 233
Cited by
Han, D., Lee, K., & Kim, Y.-H. (2003) · Applied Thermal Engineering · doi:10.1016/s1359-4311(03)00061-9 · Cited by 225
Self-citationLiang, G., & Mudawar, I. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.118864 · Cited by 203
“[125] developed a generalized correlation for flow boiling heat transfer coefficient in micro-fin tubes by modifying a prior smooth tube correlation with dimensionless parameters to account for surface modification; their approach was validated against 749 data points for five refrigerants and two fin shapes.”
MethodFlow boiling of non-azeotropic mixture R32/R1234ze(E) in horizontal microfin tubes
Kondou, C., BaBa, D., Mishima, F., & Koyama, S. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.07.009 · Cited by 115
“Table 3 compares the experimental HTC and predicted HTC by correlations proposed for other single components by Momoki et al. (1995), Thome et al. (1997), Mori et al. (2002), Yun et al. (2002), and Chamra and Mago (2007).”
MethodConvective vaporization in micro-fin tubes of different geometries
Wu, Z., Wu, Y., Sunden, B. A., & Li, W. (2012) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2012.07.012 · Cited by 122
Cho, J. M., & Kim, M. S. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.01.007 · Cited by 80
Metadata
- Authors
- Yun, R., Kim, Y., Seo, K., & Young Kim, H.
- Affiliations
- Korea University (KR)
- Corresponding author
- Kim, Yongchan
- ORCID
- Kim, Yongchan
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2002-05
- Volume
- 45
- Issue
- 10
- Pages
- 2003-2010
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W1977473698
- Cited by
- 77
- References
- 20
- Citations by year
- 2025: 2 · 2024: 5 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 4 · 2018: 4 · 2017: 1 · 2016: 3 · 2015: 6 · 2014: 4 · 2013: 6 · 2012: 4
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- evaporation heat transfer, flow boiling, microfin tubes, refrigerants, heat transfer enhancement, nucleate boiling, convective boiling, modified Reynolds number, surface tension, liquid film thickness, horizontal tube, empirical correlations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.