The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Heat transfer and friction characteristics of fin-and-tube heat exchangers
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The measured Colburn j factor and Fanning f factor agree with those of Ref. [27] for limiting cases without frosting conditions.
“To check accuracy of the present experimental study, a series of limiting cases without frosting conditions was first measured. It is found that the measured Colburn j factor and Fanning f factor agree with those of Ref. [27].”
From Thermofluid characteristics of frosted finned-tube heat exchangers (2005) · cites this paper as [27]
Citations
Cites
Heat transfer and pressure drop characteristics of flat tube and louvered plate fin surfaces
Achaichia, A., & Cowell, T. A. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90032-5 · Cited by 235
Prediction of Heat Transfer and Friction for the Louver Fin Geometry
Sahnoun, A., & Webb, R. L. (1992) · Journal of Heat Transfer · doi:10.1115/1.2911898 · Cited by 69
Flagged first, then by citations
Research works printed but not linked: 14
- Kayansayan, 1993, Heat transfer characterization of flat plain fins and round tube heat exchangers, Exper. Thermal Fluid Science, 6, 263, 10.1016/0894-1777(93)90067-S · DOI
- Jang, 1996, Numerical and experimental studies of three-dimensional plate-fin and tube heat exchangers, Int. J. Heat Mass Transfer, 39, 3057, 10.1016/0017-9310(95)00341-X · DOI
- Wang, 1996, Sensible heat and friction characteristics of plate fin-and-tube heat exchangers having plate fins, Int. J. Refrigeration, 19, 223, 10.1016/0140-7007(96)00021-7 · DOI · Paper page
- Beecher, 1987, Effects of fin pattern on the air-side heat transfer coefficient in plate finned-tube heat exchangers, ASHRAE Trans., 93, 1961
- Mirth, 1994, Corrections for predicting the air side Nusselt numbers and friction factors in child water cooling coils, Exp. Heat Transfer, 7, 144, 10.1080/08916159408946477 · DOI
- Wang, 1997, Heat transfer and friction characteristics of typical wavy fin-and-tube heat exchanger, Exper. Thermal Fluid Science, 14, 174, 10.1016/S0894-1777(96)00056-8 · DOI
- B. Youn, Y.H. Kil, H.Y. Park, K.C. Yoo, Y.S. Kim Experimental study of pressure drop and heat transfer characteristics of φ10.07 wave and wave-slit fin-tube heat exchangers with wave depth of 2 mm. In: Proceedings of the 11th Heat Transfer Conference, Kyongju, Korea, 1998, 6, pp. 333–338 · DOI
- A. Achaichia, T.A. Cowell A finite difference analysis of fully developed periodic laminar flow in inclined louver arrays. In: Proceedings of the Second UK National Heat Transfer Conference, Glasgow, UK, 1988, 2, pp. 883–888
- Webb, 1991, Flow structure in the louvered fin heat exchanger geometry, Exper. Thermal Fluid Science, 4, 205, 10.1016/0894-1777(91)90065-Y · DOI
- Wang, 1996, Heat transfer and friction characteristics of convex-louver fin-and-tube exchangers, Exp. Heat Transfer, 9, 61, 10.1080/08916159608946514 · DOI
- Wang, 1999, An experimental study of heat transfer and friction characteristics of typical louver fin-and-tube heat exchangers, Int. J. Heat Mass Transfer, 41, 817, 10.1016/S0017-9310(97)00154-3 · DOI
- ASHRAE Standard 41.2-1987 Standard Methods for Laboratory Air-flow Measurement, 1987 · DOI
- Petukhov, 1973, Heat transfer in turbulent pipe flow of gases with variable properties, Heat Transfer, Sov. Res., 5, 109
- Schmidt, 1949, Heat transfer calculation for extended surfaces, Refrig. Eng., 49, 351
Cited by
Sorted by citations
Thermofluid characteristics of frosted finned-tube heat exchangers
Yan, W.-M., Li, H.-Y., & Tsay, Y.-L. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.02.018 · Cited by 52
Self-citation
Metadata
- Authors
- Yan, W.-M., & Sheen, P.-J.
- Affiliations
- Huafan University (TW)
- Corresponding author
- Yan, Wei-Mon
- ORCID
- Yan, Wei-Mon
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2000-05
- Volume
- 43
- Issue
- 9
- Pages
- 1651-1659
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W1985360068
- Cited by
- 129
- References
- 2
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 6 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 9 · 2014: 9 · 2012: 7
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- finned tube heat exchanger, heat transfer, pressure drop, friction factor, Colburn j-factor, plate fins, wavy fins, louver fins, heat transfer coefficient
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review