The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Tamponade‐balloon for obstetrical bleeding
Abstract
Objectives: To study the effectiveness of a large volume, fluid‐filled tamponade balloon in the management of post‐partum hemorrhage originating from the implantation site of low‐lying placenta/placenta previa. Methods: A silicone, fluid‐filled balloon was designed for tamponade function, with a filling capacity volume of 500 cc of sterile saline, and strength to withstand a maximum internal and external pressure of 300 mmHg. Five women with postpartum bleeding caused by low‐lying placenta/placenta previa, and one woman with cervical ectopic pregnancy, underwent a tamponade balloon insertion as a conservative measure in the management of bleeding. Results: The tamponade balloon was used in five women with post‐partum bleeding caused by low‐lying placenta/placenta previa, and in one woman with cervical pregnancy. The balloon was effective in controlling post‐partum hemorrhage originating from the placental site of the lower uterine segment, and bleeding from the implantation site of cervical ectopic pregnancy. Conclusion: Hemostasis in cases of post‐partum bleeding caused by low‐lying placenta/placenta previa can be achieved by using a large volume, fluid‐filled tamponade balloon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Placenta previa/accreta and prior cesarean section.
Clark, S. L., Koonings, P. P., & Phelan, J. P. (1985) · PubMed · Cited by 712
Placenta Previa Accreta and Previous Cesarean Section: Some Clarifications
Matsubara, S., & Takahashi, H. (2018) · Chinese Medical Journal · doi:10.4103/0366-6999.233961 · Cited by 9
Cited by
Prevention and Management of Postpartum Haemorrhage: Green‐top Guideline No. 52
(2017) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14178 · Cited by 756
Bienstock, J. L., Eke, A. C., & Hueppchen, N. A. (2021) · New England Journal of Medicine · doi:10.1056/nejmra1513247 · Cited by 341
Balloon tamponade in the management of postpartum haemorrhage: a review
Georgiou, C. (2009) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2009.02113.x · Cited by 285
YOONG, W., RIDOUT, A., MEMTSA, M., STAVROULIS, A., AREF‐ADIB, M., RAMSAY‐MARCELLE, Z., & FAKOKUNDE, A. (2012) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2011.01153.x · Cited by 83
Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients
Cho, H. Y., Park, Y. W., Kim, Y. H., Jung, I., & Kwon, J.-Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134282 · Cited by 64
Metadata
- Authors
- Bakri, Y. N., Amri, A., & Abdul Jabbar, F.
- Venue
- International Journal of Gynecology & Obstetrics
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 74
- Issue
- 2
- Pages
- 139-142
- ISSN
- 0020-6695 (ISSN-L)
- 0020-7292
- 1879-3479
- OpenAlex
- W2023234135
- Cited by
- 356
- References
- 2
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tamponade‐balloon for obstetrical bleeding. https://app.cochat.ai/papers/10.1016/s0020-7292(01)00395-2
- The paper
- Bakri, Y. N., Amri, A., & Abdul Jabbar, F. (2001). Tamponade‐balloon for obstetrical bleeding. International Journal of Gynecology & Obstetrics. https://doi.org/10.1016/s0020-7292(01)00395-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.