Swelling and contraction of the mitochondrial matrix. II. Quantitative application of the light scattering technique to solute transport across the inner membrane.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The relationship between matrix volume and the amount of light scattered by a mitochondrial suspension has been characterized for equilibrium measurements and shown to depend in a complex but predictable manner on native structure of the mitochondrion (Beavis, A. D., Brannan, R. D., and Garlid, K. D. (1985) J. Biol. Chem. 260, 13424-13433). In the present report, we show that this characterization also applies to kinetic measurements of salt and nonelectrolyte transport. We derive and evaluate quantitative methods for determining permeability constants from light scattering kinetics. We apply these equations to the problem of whether matrix swelling itself induces permeability changes secondary to membrane stretching or changes in surface available for transport. A study of erythritol transport over a 7-fold range of matrix volume reveals dramatic changes in light scattering rates, as previously observed (Tedeschi, H. (1959) J. Biophys. Biochem. Cytol. 6, 241-252). These transitions correspond exactly to structure-dependent transitions in the relationship between absorbance and matrix volume. When this is taken into account, erythritol permeability is found to be constant over the entire volume range. Factors affecting intrinsic membrane porters, such as Mg2+ depletion and dicyclohexylcarbodiimide, are also found to be without effect on erythritol permeability. The broader significance of this study is that the light scattering technique is shown to be capable of providing quantitative answers to important questions about solute transport across the inner membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some calculations on the turbidity of mitochondria and bacteria
Koch, A. L. (1961) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(61)90599-6 · Cited by 256
Cited by
The mitochondrial permeability transition
Zoratti, M., & Szabò, I. (1995) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(95)00003-a · Cited by 2,401
Mitochondrial Transport of Cations: Channels, Exchangers, and Permeability Transition
Bernardi, P. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1127 · Cited by 1,535
The Mitochondrial K Channel as a Receptor for Potassium Channel Openers
Garlid, K. D., Paucek, P., Yarov-Yarovoy, V., Sun, X., & Schindler, P. A. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.15.8796 · Cited by 445
Self-citationHalestrap, A. P. (1989) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(89)80378-0 · Cited by 440
Mitochondrial potassium transport: the K+ cycle
Garlid, K. D., & Paucek, P. (2003) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(03)00108-7 · Cited by 365
“We have also examined mitochondrial swelling due to passive diffusion of erythritol and malonamide [62] and found ATP to have no effect.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Garlid, K. D., & Beavis, A. D.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1985-11
- Volume
- 260
- Issue
- 25
- Pages
- 13434-13441
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1523596570
- Cited by
- 116
- References
- 1
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.