Hemoglobin-haptoglobin receptor in rat liver plasma membrane.
Open accessThe DOI matches its Crossref record.
Abstract
The presence of a receptor specific for the hemoglobin . haptoglobin complex is demonstrated in rat liver plasma membranes. Hemoglobin . haptoglobin complex, administered intravenously to rats, was cleared from the circulation at a constant rate with exclusive incorporation of the molecule into hepatocytes. This incorporation was unaffected by the simultaneous injection of asialoglycoprotein or heme . hemopexin complex. In vitro experiments with isolated liver plasma membranes indicated the absence of competitive binding of these molecules to the membrane and suggested that this receptor might recognize an altered conformation of the haptoglobin moiety of the complex resulting from the binding with hemoglobin. These observations suggest that the mechanism of recognition and binding of hemoglobin . haptoglobin complex by the receptor is different from that of the asialoglycoprotein receptor or heme . hemopexin receptor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemokines and receptors in HIV encephalitis
Sanders, V. J., Pittman, C. A., White, M. G., Wang, G., Wiley, C. A., & Achim, C. L. (1998) · AIDS · doi:10.1097/00002030-199809000-00009 · Cited by 319
Cid, M. C., Grant, D. S., Hoffman, G. S., Auerbach, R., Fauci, A. S., & Kleinman, H. K. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116319 · Cited by 261
Lewis, L. A., Gray, E., Wang, Y., Roe, B. A., & Dyer, D. W. (1997) · Molecular Microbiology · doi:10.1046/j.1365-2958.1997.2501619.x · Cited by 145
“(Eaton et al., 1982; Hershko, 1975; Kinco et al., 1980; Muller-Eberhard et al., 1968).”
Lewis, L. A., & Dyer, D. W. (1995) · Journal of Bacteriology · doi:10.1128/jb.177.5.1299-1306.1995 · Cited by 97
Rocha, E. R., Smith, A., Smith, C. J., & Brock, J. H. (2001) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.2001.tb10653.x · Cited by 13
“However, hemoglobin is released during hemolysis, as may occur in some pathological conditions and is rapidly bound by haptoglobin and transported to the liver parenchymal cells [5].”
Background
Metadata
- Authors
- Kino, K., Tsunoo, H., Higa, Y., Takami, M., Hamaguchi, H., & Nakajima, H.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1980-10
- Volume
- 255
- Issue
- 20
- Pages
- 9616-9620
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1493984199
- Cited by
- 108
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemoglobin-haptoglobin receptor in rat liver plasma membrane. https://app.cochat.ai/papers/10.1016/s0021-9258(18)43436-9
- The paper
- Kino, K., Tsunoo, H., Higa, Y., Takami, M., Hamaguchi, H., & Nakajima, H. (1980). Hemoglobin-haptoglobin receptor in rat liver plasma membrane. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)43436-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.