Cited by 73Complement system in diseasesBlood Coagulation and Thrombosis MechanismsCell Adhesion Molecules Research

The DOI matches its Crossref record; the references it cites are not checked yet.

Heparin-binding properties of vitronectin are linked to complex formation as illustrated by in vitro polymerization and binding to the terminal complement complex

Open access
Høgåsen, K, Mollnes, T.E., Harboe, M·1992·Journal of Biological Chemistry

Abstract

Vitronectin (VN, complement S-protein) is a multifunctional protein which participates in cell adhesion, coagulation, fibrinolysis, and protection against complement lysis. VN is incorporated into several complexes, such as the terminal complement complex and thrombin-antithrombin III, and is bound to plasminogen activator inhibitor 1. The present study showed that purified VN spontaneously forms polymers of approximately 1000 kDa with a Stokes radius of 10 nm. The polymers are to a varying extent stabilized by disulfide bonds, but are quite stable even after reduction and alkylation, indicating the importance of noncovalent bonds. Plasma VN circulates mainly as a 65/75-kDa monomer containing a cryptic heparin-binding site which is exposed upon a conformational change induced by different stimuli, such as coagulation, heating, adsorption to surfaces, or exposure to acids, urea, or other denaturating agents. In the present study, VN was demonstrated to expose its heparin-binding site and its conformationally dependent 8E6 epitope when incorporated into the terminal complement complex. We suggest that exposure of the heparin-binding site and a putative hydrophobic binding site of VN are linked events dependent upon the same conformational change. In vivo, complex formation probably induces the heparin-binding site. Such a link might also explain why purified heparin-binding VN spontaneously forms polymers. The heparin-binding site may be involved in the elimination of multimolecular complexes containing VN.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(18)50058-2

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists haven’t been fetched yet

References 21 · Cited by 73

Metadata

Authors
Høgåsen, K., Mollnes, T. E., & Harboe, M.
Affiliations
University of Oslo (NO)
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1992-11
Volume
267
Issue
32
Pages
23076-23082
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1545503393
Cited by
73
References
21
Citations by year
2026: 1 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 1 · 2015: 2 · 2013: 4
FWCI
3.54
Type
journal article
Language
en
Open access
Locations
  • Journal of Biological Chemistry (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Immunology › Complement system in diseases
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Immunology and Allergy › Cell Adhesion Molecules Research
Keywords
vitronectin, heparin-binding site, membrane attack complex, protein polymerization, conformational change, disulfide bonds, hydrophobic binding site, protein complex formation
MeSH terms
Antibodies, Monoclonal, Epitopes, Binding Sites, Blood Proteins, Chromatography, Affinity, Chromatography, Gel, Chromatography, High Pressure Liquid, Chromatography, Ion Exchange, Glycoproteins, Heparin, Humans, Immunoglobulin G, Immunoglobulin Fab Fragments, Immunosorbent Techniques, Molecular Weight, Blotting, Western, Vitronectin, Macromolecular Substances

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review