The DOI matches its Crossref record.
COLORIMETRIC DETERMINATION OF BLOOD LIPIDES
Open accessAbstract
Extraction-As the oxidation is essentially non-specific, the plasma extract must be as free of non-lipide reducing substances as possible. All solvents should be tested occasionally for reducing residues remaining after evaporation, and redistilled if necessary. Ether should be maintained peroxide-free. The determinations reported here followed a conventional alcohol-ether extraction and subsequent reextraction in petroleum ether. Although Folch and Van Slyke (2) have shown that this procedure carries through significant amounts of urea, it has been found that urea, even in amounts considerably in excess of what might occur, produces no color change in the dichromate reagent. Methods of extraction based on primary elution of water-soluble substances (Folch and Van Slyke (3); Ahrensl) have been used recently and offer definite advantages. Reagent-20 gm. of K2Crp01, c.p., are powdered in a mortar and added slowly with shaking to 1000 ml. of HzS04, c.p. (sp. gr. 1.84) maintained at a temperature not exceeding 100”. There should be no undissolved residue. If the reagent is protected from contamination and from exposure to direct sunlight, it darkens only very slowly with age. This does not affect the calorimetry, however, as the reagent itself is used as the reference blank. The addition of catalysts, including Hg, Pd, and Ag, had no effect on the oxidizing power of the reagent. Silver, recommended by Bloor (I), should not be used with biological extracts, as the latter may contain enough chloride (4) to interfere with the calorimetry. Oxidation-In dealing with extracts of normal human plasma, an aliquot representing from 0.1 to 0.7 ml. of plasma is transferred to a 25 ml. volumetric flask. The solvent is evaporated under nitrogen (water-pumped)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[54] Thin-layer chromatography of lipids
(1969) · Methods in Enzymology · doi:10.1016/s0076-6879(69)14056-2 · Cited by 573
A rapid chemical method for quantification of lipids separated by thin-layer chromatography
Amenta, J. S. (1964) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)40251-2 · Cited by 391
Determination of glycerides in blood serum
Carlson, L. A., & Wadström, L. B. (1959) · Clinica Chimica Acta · doi:10.1016/0009-8981(59)90130-5 · Cited by 272
EARLY EFFECTS OF FAT INGESTION ON LIPIDS AND LIPO-PROTEINS OF SERUM IN MAN
Havel, R. J. (1957) · Journal of Clinical Investigation · doi:10.1172/jci103491 · Cited by 223
Lipid analysis by quantitative thin‐layer chromatography
Privett, O. S., Blank, M. L., Codding, D. W., & Nickell, E. C. (1965) · Journal of the American Oil Chemists' Society · doi:10.1007/bf02635573 · Cited by 172
Metadata
- Authors
- Bragdon, J. H.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1951-06
- Volume
- 190
- Issue
- 2
- Pages
- 513-517
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1822895582
- Cited by
- 493
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: COLORIMETRIC DETERMINATION OF BLOOD LIPIDES. https://app.cochat.ai/papers/10.1016/s0021-9258(18)55999-8
- The paper
- Bragdon, J. H. (1951). COLORIMETRIC DETERMINATION OF BLOOD LIPIDES. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)55999-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.