The DOI matches its Crossref record.
DETERMINATION OF SERUM PROTEINS BY MEANS OF THE BIURET REACTION
Open accessAbstract
In the course of an investigation of the biochemical changes following experimental liver injury we felt the need of a simple, rapid, and accurate method for determining the protein fractions in small amounts of serum. Among the simpler procedures known, the biuret reaction seemed to offer the most encouraging possibilities. Variations and improvements in the application of the biuret reaction to clinical chemistry can be traced in the works of Autenrieth (l), Hiller (2), Fine (3), Kingsley (4), and Robinson and Hogden (5). Kingsley (6) simplified the technique by adding serum directly to a “one piece” reagent. Efforts have been made to increase the stability of such biuret reagents with ethylene glycol (7), tartrate (8), and citrate (9)) We began our investigation with Kingsley’s (6) method and report briefly on the two main difficulties encountered in its use. The first is that the total protein (TP) reagent and, to a lesser extent, the albumin (ALB) reagent are not sufficiently stable. The length of time they remain so depends upon the technique of their preparation. One consequence of this variable stability is a difficulty in duplicating calibration curves with different lots of reagent. Errors may arise when results with a new reagent are read from an old calibration curve. Serious errors occur if a reagent is used after the separation of any black deposit gives evidence of deterioration. A second difficulty has been that total protein estimations made with the TP reagent and read, as prescribed, from calibration curves prepared with the ALB reagent have tended to be too low. Recorded in Table I are the results of a number of analyses in which Kingsley’s biuret procedure has been compared with the Kjeldahl method2 on both normal and ab-
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
Topology of superoxide production from different sites in the mitochondrial electron transport chain
St-Pierre, J., Buckingham, J. A., Roebuck, S. J., & Brand, M. D. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m207217200 · Cited by 1,545
Biochemical Adaptations in Muscle
Holloszy, J. O. (1967) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)96046-1 · Cited by 1,517
Zimmerman, S. B., & Trach, S. O. (1991) · Journal of Molecular Biology · doi:10.1016/0022-2836(91)90499-v · Cited by 1,337
Metadata
- Authors
- Gornall, A. G., Bardawill, C. J., & David, M. M.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1949-02
- Volume
- 177
- Issue
- 2
- Pages
- 751-766
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1506043065
- Cited by
- 16,158
- References
- 0
- FWCI
- 40.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DETERMINATION OF SERUM PROTEINS BY MEANS OF THE BIURET REACTION. https://app.cochat.ai/papers/10.1016/s0021-9258(18)57021-6
- The paper
- Gornall, A. G., Bardawill, C. J., & David, M. M. (1949). DETERMINATION OF SERUM PROTEINS BY MEANS OF THE BIURET REACTION. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)57021-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.