The DOI matches its Crossref record.
Phosphorus Assay in Column Chromatography
Open accessAbstract
Malerials-30 per cent hydrogen peroxide (Baker and Adamson, phosphorus-free) and the ammonium molybdate, (NHJ6lMo7024.4Hz0, wereused. The Fiske and SubbaRow (I) reagent was prepared by adding 0.5 gm. of purified (1) 1-amino-2naphthol-4-sulfonic acid (Eastman Organic Chemicals) with mechanical stirring to 200 ml. of freshly prepared 15 per cent sodium bisulfite (anhydrous), followed by 1.0 gm. of anhydrous sodium sulfite. The solution was filtered, stored in a dark bottle, and iresmy prepared weekly. Procedure for Total Phosphorus Analysis-Up to 2.0 ml. of the sample to be analyzed and 0.5 ml. of 10 N HsS04 were placed in a 12-ml. conical centrifuge tube and heated in a 150-160”-oven for at least 3 hours. 2 drops of 30 per cent HsOz were added, and the solution was returned to the oven for at least 1.5 hours more to complete the combustion and to decompose all the peroxide. 4.6 ml. of 0.22 per cent ammonium molybdate (or 4.4 ml. of Hz0 plus 0.2 ml. of 5 per cent ammonium molybdate) and 0.2 ml. of the Fiske-SubbaRow reagent were added, mixed thoroughly, and heated for 7 minutes in a boiling water bath, with marbles covering the tubes. The optical density at 830 rnp was recorded with the use of a Beckman model B photometer with the red-sensitive phototube. This procedure for color development at 100” is hereafter designated the heating method. A longer period of digestion at 150-160” did not influence the results. I f an aliquot greater than 2.0 ml. was to be analyzed, it was first evaporated to dryness in a mechanical convection oven at about 110”. 1.0 ml. of H20 and 0.5 ml. of the 10 N HzS04 were then added with rinsing of the walls of the tubes, and the assay was continued as above. When more than 1 mmole of ammonium formate was present, the sample was evaporated to dryness at 110” in order to remove the formate; then Hz0 and H2S04 were added and the analysis continued as above. If the highest accuracy was not required, the following manipulations simplified and speeded multiple total phosphorus determinations on the eluates from column chromatographic separations. Aliquots from successive fractions were transferred to the 12-ml. centrifuge tubes with an automatic syringe,’ and the various reagents were delivered from elevated storage bottles
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assay for lipid peroxides in animal tissues by thiobarbituric acid reaction
Ohkawa, H., Ohishi, N., & Yagi, K. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90738-3 · Cited by 29,297
Berridge, M. J., Dawson, R. M. C., Downes, C. P., Heslop, J. P., & Irvine, R. F. (1983) · Biochemical Journal · doi:10.1042/bj2120473 · Cited by 1,954
The selenoenzyme phospholipid hydroperoxide glutathione peroxidase
Ursini, F., Maiorino, M., & Gregolin, C. (1985) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(85)90182-5 · Cited by 990
A rapid and sensitive sub-micro phosphorus determination
Böttcher, C. J. F., Van gent, C. M., & Pries, C. (1961) · Analytica Chimica Acta · doi:10.1016/0003-2670(61)80041-x · Cited by 963
Shinitzky, M., & Barenholz, Y. (1974) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)42780-4 · Cited by 938
Metadata
- Authors
- Bartlett, G. R.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1959-03
- Volume
- 234
- Issue
- 3
- Pages
- 466-468
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1513897103
- Cited by
- 12,801
- References
- 0
- FWCI
- 32.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phosphorus Assay in Column Chromatography. https://app.cochat.ai/papers/10.1016/s0021-9258(18)70226-3
- The paper
- Bartlett, G. R. (1959). Phosphorus Assay in Column Chromatography. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)70226-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.