Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 12,801

The DOI matches its Crossref record.

Phosphorus Assay in Column Chromatography

Open access
Bartlett, Grant R.·1959·Journal of Biological Chemistry

Abstract

Malerials-30 per cent hydrogen peroxide (Baker and Adamson, phosphorus-free) and the ammonium molybdate, (NHJ6lMo7024.4Hz0, wereused. The Fiske and SubbaRow (I) reagent was prepared by adding 0.5 gm. of purified (1) 1-amino-2naphthol-4-sulfonic acid (Eastman Organic Chemicals) with mechanical stirring to 200 ml. of freshly prepared 15 per cent sodium bisulfite (anhydrous), followed by 1.0 gm. of anhydrous sodium sulfite. The solution was filtered, stored in a dark bottle, and iresmy prepared weekly. Procedure for Total Phosphorus Analysis-Up to 2.0 ml. of the sample to be analyzed and 0.5 ml. of 10 N HsS04 were placed in a 12-ml. conical centrifuge tube and heated in a 150-160”-oven for at least 3 hours. 2 drops of 30 per cent HsOz were added, and the solution was returned to the oven for at least 1.5 hours more to complete the combustion and to decompose all the peroxide. 4.6 ml. of 0.22 per cent ammonium molybdate (or 4.4 ml. of Hz0 plus 0.2 ml. of 5 per cent ammonium molybdate) and 0.2 ml. of the Fiske-SubbaRow reagent were added, mixed thoroughly, and heated for 7 minutes in a boiling water bath, with marbles covering the tubes. The optical density at 830 rnp was recorded with the use of a Beckman model B photometer with the red-sensitive phototube. This procedure for color development at 100” is hereafter designated the heating method. A longer period of digestion at 150-160” did not influence the results. I f an aliquot greater than 2.0 ml. was to be analyzed, it was first evaporated to dryness in a mechanical convection oven at about 110”. 1.0 ml. of H20 and 0.5 ml. of the 10 N HzS04 were then added with rinsing of the walls of the tubes, and the assay was continued as above. When more than 1 mmole of ammonium formate was present, the sample was evaporated to dryness at 110” in order to remove the formate; then Hz0 and H2S04 were added and the analysis continued as above. If the highest accuracy was not required, the following manipulations simplified and speeded multiple total phosphorus determinations on the eluates from column chromatographic separations. Aliquots from successive fractions were transferred to the 12-ml. centrifuge tubes with an automatic syringe,’ and the various reagents were delivered from elevated storage bottles

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(18)70226-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 12,801

Metadata

Authors
Bartlett, G. R.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1959-03
Volume
234
Issue
3
Pages
466-468
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1513897103
Cited by
12,801
References
0
FWCI
32.26
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phosphorus Assay in Column Chromatography. https://app.cochat.ai/papers/10.1016/s0021-9258(18)70226-3
The paper
Bartlett, G. R. (1959). Phosphorus Assay in Column Chromatography. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)70226-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.