The DOI matches its Crossref record.
A RAPID PHOTOELECTRIC METHOD FOR THE DETERMINATION OF GLUCOSE IN BLOOD AND URINE
Open accessAbstract
The reduction of potassium ferricyanide to ferrocyanide by glucose has been used as the basis of several successful quantitative methods for glucose. In the most popular of these, the Hagedorn and Jensen (1) method, the excess of ferricyanide is determined by iodometric titration. In the Folin (2) micromethod, the ferrocyanide formed is converted to Prussian blue and measured calorimetrically. Only in the Hawkins and Van Slyke (3) method is use made of the fact that ferricyanide solutions are yellow and ferrocyanide colorless. In this method, glucose is estimated by measuring the time required completely to decolorize a ferricyanide solution. The Hawkins and Van Slyke procedure is easy and rapid. Its apparent lack of popularity is probably due to the fact that the exact end-point is difficult to determine and that any error made is irreparable. Furthermore, it does not lend itself to multiple determinations. The present author has been able to obviate the difficulties of the Hawkins and Van Slyke method and yet retain the principle involved. The resulting method is simple, easy, and accurate. In it, the diminution in the yellow color of an excess of ferricyanide by glucose is measured in a photoelectric calorimeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brain Metabolism during Fasting*
Owen, O. E., Morgan, A. P., Kemp, H. G., Sullivan, J. M., Herrera, M. G., & Cahill, G. F. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105650 · Cited by 1,646
Martin, B. C., Warram, J. H., Krolewski, A. S., Soeldner, J. S., Kahn, C. R., Martin, B. C., & Bergman, R. N. (1992) · The Lancet · doi:10.1016/0140-6736(92)92814-v · Cited by 1,158
Warram, J. H., Martin, B. C., Krolewski, A. S., Soeldner, J. S., & Kahn, C. R. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-12-909 · Cited by 1,038
Studies of pancreatic alpha cell function in normal and diabetic subjects
Unger, R. H., Aguilar-Parada, E., Müller, W. A., & Eisentraut, A. M. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106297 · Cited by 837
Plasma Amino Acid Levels and Insulin Secretion in Obesity
Felig, P., Marliss, E., & Cahill, G. F. (1969) · New England Journal of Medicine · doi:10.1056/nejm196910092811503 · Cited by 812
Metadata
- Authors
- Hoffman, W. S.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1937-08
- Volume
- 120
- Issue
- 1
- Pages
- 51-55
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1603688983
- Cited by
- 1,286
- References
- 0
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A RAPID PHOTOELECTRIC METHOD FOR THE DETERMINATION OF GLUCOSE IN BLOOD AND URINE. https://app.cochat.ai/papers/10.1016/s0021-9258(18)74360-3
- The paper
- Hoffman, W. S. (1937). A RAPID PHOTOELECTRIC METHOD FOR THE DETERMINATION OF GLUCOSE IN BLOOD AND URINE. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)74360-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.