Characteristics of self-quenching of the fluorescence of lipid-conjugated rhodamine in membranes.
Open accessThe DOI matches its Crossref record.
Abstract
Self- or concentration quenching of octadecylrhodamine B (C18-Rh) fluorescence increases linearly in egg phosphatidylcholine (PC) vesicles but exponentially in vesicles composed of egg PC:cholesterol, 1:1, as the probe concentration is raised to 10 mol%. Cholesterol-dependent enhancement of self-quenching also occurs when N-(lissamine-rhodamine-B-sulfonyl)dioleoylphosphatidylethanolamine is substituted for C18-Rh and resembles that in dipalmitoylphosphatidylcholine vesicles below, as opposed to above, the phase transition. These effects are not due to changes in dimer:monomer absorbance. Stern-Volmer plots indicate a dependence of quenching on nonfluorescent dimers both in the presence and absence of cholesterol. Decreases in fluorescence lifetimes with increasing probe concentration parallel decreases in residual fluorescence of C18-Rh with increasing probe concentration in PC and PC + cholesterol membranes, respectively. Decreases in the steady-state polarization of C18-Rh fluorescence as its concentration is raised to 10 mol% indicate energy transfer with emission between probe molecules in PC and to a lesser extent in PC + cholesterol membranes. The calculated R0 for 50% efficiency of energy transfer from excited state probe to monomer was 55-58 A and to dimer was 27 A. Since lateral diffusion of C18-Rh is probably too slow to permit collisional quenching during the lifetime of the probe, even if C18-Rh were concentrated in a separate phase, C18-Rh self-quenching appears to be due mainly to energy transfer without emission to nonfluorescent dimers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultee, A., Bennik, M. H. J., & Moezelaar, R. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.4.1561-1568.2002 · Cited by 1,602
“dilution of the probe, which is caused by an expansion of the membrane (9, 15).”
BackgroundFluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634
Structure of ribonuclease H phased at 2 a resolution by MAD analysis of the selenomethionyl protein
Yang, W., Hendrickson, W. A., Crouch, R. J., & Satow, Y. (1990) · Science · doi:10.1126/science.2169648 · Cited by 473
Characterizing Voltage-Dependent Conformational Changes in the K Channel with Fluorescence
Cha, A., & Bezanilla, F. (1997) · Neuron · doi:10.1016/s0896-6273(00)80403-1 · Cited by 341
Pérez-Fons, L., GarzÓn, M. T., & Micol, V. (2010) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf9026487 · Cited by 273
Chernomordik, L., Chanturiya, A., Green, J., & Zimmerberg, J. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)79966-0 · Cited by 248
Austin, C. D., Wen, X., Gazzard, L., Nelson, C., Scheller, R. H., & Scales, S. J. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509035102 · Cited by 237
The Interaction of Flavonoids with Membranes: Potential Determinant of Flavonoid Antioxidant Effects
Erlejman, A. G., Verstraeten, S. V., Fraga, C. G., & Oteiza, P. I. (2004) · Free Radical Research · doi:10.1080/10715760400016105 · Cited by 236
“Maximal fluorescence is achieved after the total disruption of the bilayer.([32]) When assayed at 5mM concentration, flavanols and flavonols were the only”
BackgroundMelikyan, G. B., White, J. M., & Cohen, F. S. (1995) · The Journal of cell biology · doi:10.1083/jcb.131.3.679 · Cited by 227
“The fluorescence of this high concentration of rhoPE was significantly, but not completely, self-quenched (MacDonald, 1990).”
Collective fluorescence switching of counterion-assembled dyes in polymer nanoparticles
Reisch, A., Didier, P., Richert, L., Oncul, S., Arntz, Y., Mély, Y., & Klymchenko, A. S. (2014) · Nature Communications · doi:10.1038/ncomms5089 · Cited by 226
Chernomordik, L. V., Leikina, E., Frolov, V., Bronk, P., & Zimmerberg, J. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.136.1.81 · Cited by 214
“Although both the specific fluorescence of membrane dyes and their lateral mobility can be changed by altering membrane composition (Golan et al., 1988; MacDonald, 1990), the effects presented cannot be explained by some lipid-dependent changes in the properties of our probes.”
Verstraeten, S. V., Keen, C. L., Schmitz, H. H., Fraga, C. G., & Oteiza, P. I. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(02)01185-1 · Cited by 211
Fluorescent lipid probes: some properties and applications (a review)
Maier, O., Oberle, V., & Hoekstra, D. (2002) · Chemistry and Physics of Lipids · doi:10.1016/s0009-3084(02)00017-8 · Cited by 192
Kraft, J. C., & Ho, R. J. Y. (2014) · Biochemistry · doi:10.1021/bi500021j · Cited by 161
Metadata
- Authors
- MacDonald, R. I.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1990-08
- Volume
- 265
- Issue
- 23
- Pages
- 13533-13539
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1522028136
- Cited by
- 147
- References
- 0
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.