The DOI matches its Crossref record.
Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores
Open accessAbstract
A new group of fluorescent indicators with visible excitation and emission wavelengths has been synthesized for measurements of cytosolic free Ca2+. The five compounds, "rhod-1," "rhod-2," "fluo-1," "fluo-2," and "fluo-3" (Figs. 2 and 3), combine the 8-coordinate tetracarboxylate chelating site of 1,2-bis(2-amino-phenoxyethane-N,N,N',N'-tetraacetic acid with a xanthene chromophore to give a rhodamine-like or fluorescein-like fluorophore. Binding of Ca2+ increases the fluorescence by up to 40-fold. The Ca2+ dissociation constants are in the range 0.37-2.3 microM, so that the new indicators should give better resolution of high [Ca2+] levels than previously obtainable with quin-2 or fura-2. The visible excitation wavelengths of the new compounds are more convenient for fluorescence microscopy and flow cytometry than the UV required by previous indicators. However, the new dyes' increase in fluorescence upon binding calcium is not accompanied by a wavelength shift, so they are unsuitable for measurements using ratios at two wavelengths. The most promising dye of this series is fluo-3, whose initial biological testing in fibroblasts is described in the following paper (Kao, J. P. Y., Harootunian, A. T., and Tsien, R. Y. (1989) J. Biol. Chem. 264, 8171-8178).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Setsukinai, K.-I., Urano, Y., Kakinuma, K., Majima, H. J., & Nagano, T. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m209264200 · Cited by 1,301
Mitochondria and neuronal survival
Nicholls, D. G., & Budd, S. L. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.1.315 · Cited by 1,243
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Calmodulin Trapping by Calcium-Calmodulin-Dependent Protein Kinase
Meyer, T., Hanson, P. I., Stryer, L., & Schulman, H. (1992) · Science · doi:10.1126/science.256.5060.1199 · Cited by 637
Estimating Intracellular Calcium Concentrations and Buffering without Wavelength Ratioing
Maravall, M., Mainen, Z. F., Sabatini, B. L., & Svoboda, K. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76809-3 · Cited by 416
Metadata
- Authors
- Minta, A., Kao, J. P. Y., & Tsien, R. Y.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1989-05
- Volume
- 264
- Issue
- 14
- Pages
- 8171-8178
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1601936385
- Cited by
- 1,613
- References
- 0
- FWCI
- 44.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores. https://app.cochat.ai/papers/10.1016/s0021-9258(18)83165-9
- The paper
- Minta, A., Kao, J. P. Y., & Tsien, R. Y. (1989). Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)83165-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.